Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 73 of the 88 references it cites were found in a registry or an index; 32 of the 54 sources its claims cite were checked for support.

Penning micro-trap for quantum computing

Open access

Abstract

Abstract Trapped ions in radio-frequency traps are among the leading approaches for realizing quantum computers, because of high-fidelity quantum gates and long coherence times 1–3 . However, the use of radio-frequencies presents several challenges to scaling, including requiring compatibility of chips with high voltages 4 , managing power dissipation 5 and restricting transport and placement of ions 6 . Here we realize a micro-fabricated Penning ion trap that removes these restrictions by replacing the radio-frequency field with a 3 T magnetic field. We demonstrate full quantum control of an ion in this setting, as well as the ability to transport the ion arbitrarily in the trapping plane above the chip. This unique feature of the Penning micro-trap approach opens up a modification of the quantum charge-coupled device architecture with improved connectivity and flexibility, facilitating the realization of large-scale trapped-ion quantum computing, quantum simulation and quantum sensing.

Overview

CoChat Summary

TL;DR

The paper reports a micro-fabricated Penning ion trap for quantum computing that replaces rf confinement with a 3 T magnetic field, removing key scaling constraints of conventional rf traps. The authors demonstrate full quantum control of a single ^9Be^+ ion and arbitrary 2D transport above the chip with negligible transport-induced heating.

Key findings

  • The trap uses a static quadrupolar electric potential plus a homogeneous magnetic field of about 3 T, and the ions are held 152 μm above the chip surface.
  • The authors report a qubit coherence time of 1.9(2) ms with Raman beams; with Uhrig dynamical decoupling, the extracted coherence time increases to 3.2(1) ms, 5.8(3) ms, and 8.0(7) ms for orders 1, 3, and 5, respectively.
  • Motional-state Ramsey measurements give a 1/e coherence time of 66(5) ms, extended to 240(20) ms with an echo pulse and to 440(50) ms when trap electrodes are detached from external voltage sources.
  • They measure heating rates and state that the axial-mode electric-field noise is lower than any comparable measurement in a trap of similar size; transport over up to 250 μm shows no evidence of motional excitation beyond natural heating.

Methods

  • Single ^9Be^+ ions were trapped in a cryogenic, ultrahigh-vacuum surface-electrode Penning trap inside a 3 T superconducting magnet; the trap was fabricated with 25 electrodes on a planar sapphire substrate and operated at 6.5 K.
  • Quantum control used stimulated Raman transitions and microwave fields for qubit operations, Doppler cooling, sideband cooling, Ramsey spectroscopy, and sideband thermometry.
  • The main analyses included spin-coherence measurements, motional heating measurements, motional Ramsey/echo sequences, and adiabatic 2D ion transport with fluorescence imaging.

Limitations

  • The study is restricted to a single trap site and a single ion, so multi-site QCCD operation is not yet demonstrated.
  • The paper states that scaling to large numbers of sites will require better loading, improved light delivery, and further studies of heating versus ion-electrode distance.
  • Evident from the text: several reported values are stated qualitatively or are partially omitted in the provided excerpt (for example some mean occupations/temperatures and some heating-rate expressions), so the summary is limited to the explicitly stated numbers.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41586-024-07111-x

Cites

73 of 73 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Surface-electrode Penning trap. a, Schematic showing the middle section of the micro-fabricated surface-electrode trap. The trap chip is embedded in a uniform magnetic field along the z axis, and the application of d.c. voltages on the electrodes leads to 3D confinement of the ion at a height h ≃ 152 μm above the surface. Electrodes labelled ‘d.c. + rf’ are used for coupling the radial modes during Doppler cooling. b, Micrographic image of the trap chip, with an overlay of the direction of the laser beams (all near 313 nm) and microwave radiation (near ω0 ≃ 2π × 83.2 GHz) required for manipulating the spin and motion of the ion. All laser beams run parallel to the surface of the trap and are switched on or off using acousto-optic modulators, whereas microwave radiation is delivered to the ion by a horn antenna close to the chip. Scale bar, 100 μm. c, Epicyclic motion of the ion in the radial plane (x–y) resulting from the sum of the two circular eigenmodes, the cyclotron and the magnetron modes. d, Electronic structure of the 9Be+ ion, with the relevant transitions used for coherent and incoherent operations on the ion. Only the levels with nuclear spin mI = +3/2 are shown. The virtual level (dashed line) used for Raman excitation is detuned ΔR ≃ +2π × 150 GHz from the 2p 2P3/2 |mI = +3/2, mJ = +3/2⟩ state.
Fig. 1 Surface-electrode Penning trap. a, Schematic showing the middle section of the micro-fabricated surface-electrode trap. The trap chip is embedded in a uniform magnetic field along the z axis, and the application of d.c. voltages on the electrodes leads to 3D confinement of the ion at a height h ≃ 152 μm above the surface. Electrodes labelled ‘d.c. + rf’ are used for coupling the radial modes during Doppler cooling. b, Micrographic image of the trap chip, with an overlay of the direction of the laser beams (all near 313 nm) and microwave radiation (near ω0 ≃ 2π × 83.2 GHz) required for manipulating the spin and motion of the ion. All laser beams run parallel to the surface of the trap and are switched on or off using acousto-optic modulators, whereas microwave radiation is delivered to the ion by a horn antenna close to the chip. Scale bar, 100 μm. c, Epicyclic motion of the ion in the radial plane (x–y) resulting from the sum of the two circular eigenmodes, the cyclotron and the magnetron modes. d, Electronic structure of the 9Be+ ion, with the relevant transitions used for coherent and incoherent operations on the ion. Only the levels with nuclear spin mI = +3/2 are shown. The virtual level (dashed line) used for Raman excitation is detuned ΔR ≃ +2π × 150 GHz from the 2p 2P3/2 |mI = +3/2, mJ = +3/2⟩ state.CC BY · PubMed Central
Fig. 2 Motional coherence. a, Bright-state population P↑ measured after applying the first red or blue axial sideband probe-pulse to the sideband-cooled ion. As the bright state |↑⟩ has a higher energy than the dark state |↓⟩, the blue sideband cannot be driven when the ion is in the ground state of the axial mode. b, Average phonon number n¯ calculated using the sideband-ratio method44 for all three modes as a function of increasing twait. The purple and orange points indicate data taken with the trap connected and detached, respectively. The heating rates are extracted from the slopes of the linear fits. c, Motional dephasing of the axial mode observed by Ramsey spectroscopy. The purple points indicate data taken with an echo pulse in the sequence. The orange points indicate data taken with an echo pulse, in which, additionally, the trap was detached between Doppler cooling and the detection pulse. Whereas the dataset with the voltage sources detached is taken at ωz ≃ 2π × 2.5 MHz, the two data series with the trap attached are taken at an axial mode frequency ωz ≃ 2π × 3.1 MHz. The dashed lines show the 1/e line normalized to the Gaussian fits. All error bars indicate the standard error.
Fig. 2 Motional coherence. a, Bright-state population P↑ measured after applying the first red or blue axial sideband probe-pulse to the sideband-cooled ion. As the bright state |↑⟩ has a higher energy than the dark state |↓⟩, the blue sideband cannot be driven when the ion is in the ground state of the axial mode. b, Average phonon number n¯ calculated using the sideband-ratio method44 for all three modes as a function of increasing twait. The purple and orange points indicate data taken with the trap connected and detached, respectively. The heating rates are extracted from the slopes of the linear fits. c, Motional dephasing of the axial mode observed by Ramsey spectroscopy. The purple points indicate data taken with an echo pulse in the sequence. The orange points indicate data taken with an echo pulse, in which, additionally, the trap was detached between Doppler cooling and the detection pulse. Whereas the dataset with the voltage sources detached is taken at ωz ≃ 2π × 2.5 MHz, the two data series with the trap attached are taken at an axial mode frequency ωz ≃ 2π × 3.1 MHz. The dashed lines show the 1/e line normalized to the Gaussian fits. All error bars indicate the standard error.CC BY · PubMed Central
Fig. 3 Demonstration of 2D transport. A single ion is transported adiabatically in the x–z plane (normal to the imaging optical axis). The ion is illuminated for 500 μs at a total of 58 positions, here defined by the ETH Zürich logo (see inset for reference image). The red circle indicates the initial position in which the ion is Doppler-cooled. The ion is moved across a region spanning approximately 40 μm and 75 μm along the x (radial) and z (axial) directions, respectively. The sequence is repeated 172 times to accumulate the image.
Fig. 3 Demonstration of 2D transport. A single ion is transported adiabatically in the x–z plane (normal to the imaging optical axis). The ion is illuminated for 500 μs at a total of 58 positions, here defined by the ETH Zürich logo (see inset for reference image). The red circle indicates the initial position in which the ion is Doppler-cooled. The ion is moved across a region spanning approximately 40 μm and 75 μm along the x (radial) and z (axial) directions, respectively. The sequence is repeated 172 times to accumulate the image.CC BY · PubMed Central
Extended Data Fig. 1 Spin coherence. Population in the |↑⟩ state a. as a function of the wait time twait in the detuned Ramsey experiment, and b. for the first three odd orders of the Uhrig dynamical decoupling sequence performed using the Raman beams. In the Uhrig sequence, the phase of the final pulse is chosen to maximise population at 0 wait time. As there is always a π-pulse in the centre of the wait time, any static detuning offsets are cancelled and the population in the |↑⟩ state is proportional to the contrast. The coherence time is extracted from an empirical fit to an exponential function in a. and a Gaussian in b. All error bars in this figure indicate the standard error.
Extended Data Fig. 1 Spin coherence. Population in the |↑⟩ state a. as a function of the wait time twait in the detuned Ramsey experiment, and b. for the first three odd orders of the Uhrig dynamical decoupling sequence performed using the Raman beams. In the Uhrig sequence, the phase of the final pulse is chosen to maximise population at 0 wait time. As there is always a π-pulse in the centre of the wait time, any static detuning offsets are cancelled and the population in the |↑⟩ state is proportional to the contrast. The coherence time is extracted from an empirical fit to an exponential function in a. and a Gaussian in b. All error bars in this figure indicate the standard error.CC BY · PubMed Central
Extended Data Fig. 2 Heating during transport. Bright-state population P↑ measured after applying the first red or blue axial sideband probe-pulse before and after a number of shuttling events. In panel a, the ion is moved along the z-axis (axial direction), while in panel b, the ion is moved along the x-axis (in-plane radial direction) - in both cases, the distance moved is approximately 30 μm. For the axial mode, the transport sequence between the initial and final locations is repeated 10 times before the temperature is probed. A single one-way transport sequence has a duration of approximately 300 μs. The temperature is then compared to the case where the ion is held at the initial position for an equivalent total waiting time; this case is labelled as ‘No Transport’ in the figure. In the case of the magnetron and cyclotron modes, the transport-sequence is repeated 4 times instead. We see no appreciable change in the ion temperature when the transport time is increased. All error bars in this figure indicate the standard error.
Extended Data Fig. 2 Heating during transport. Bright-state population P↑ measured after applying the first red or blue axial sideband probe-pulse before and after a number of shuttling events. In panel a, the ion is moved along the z-axis (axial direction), while in panel b, the ion is moved along the x-axis (in-plane radial direction) - in both cases, the distance moved is approximately 30 μm. For the axial mode, the transport sequence between the initial and final locations is repeated 10 times before the temperature is probed. A single one-way transport sequence has a duration of approximately 300 μs. The temperature is then compared to the case where the ion is held at the initial position for an equivalent total waiting time; this case is labelled as ‘No Transport’ in the figure. In the case of the magnetron and cyclotron modes, the transport-sequence is repeated 4 times instead. We see no appreciable change in the ion temperature when the transport time is increased. All error bars in this figure indicate the standard error.CC BY · PubMed Central
Extended Data Fig. 3 Cryogenic vacuum apparatus. Rendering of the cryogenic vacuum apparatus placed inside the magnet bore. Laser light is delivered along the bore to the trap enclosure, passing focusing lenses and a vacuum viewport. Ion fluorescence is collected using a Schwarzschild objective and directed out of the apparatus and the magnet bore using a mirror.
Extended Data Fig. 3 Cryogenic vacuum apparatus. Rendering of the cryogenic vacuum apparatus placed inside the magnet bore. Laser light is delivered along the bore to the trap enclosure, passing focusing lenses and a vacuum viewport. Ion fluorescence is collected using a Schwarzschild objective and directed out of the apparatus and the magnet bore using a mirror.CC BY · PubMed Central
Extended Data Fig. 4 Trap enclosure. Top view of the trap enclosure with the Schwarzschild objective and lid removed. The laser beams are directed across the trap chip by an array of mirrors. A horn antenna delivers microwave radiation across the trap.
Extended Data Fig. 4 Trap enclosure. Top view of the trap enclosure with the Schwarzschild objective and lid removed. The laser beams are directed across the trap chip by an array of mirrors. A horn antenna delivers microwave radiation across the trap.CC BY · PubMed Central
Extended Data Fig. 5 Trap detachment. Schematic of the switch arrangement used to detach a trap electrode from the external DAC. Three MOSFET-based switches with an on-state resistance of 11 Ω and off-state capacitance Coff = 0.45 pF are chained and interleaved with capacitors C = 560 pF, forming capacitive dividers for improved isolation at radio frequencies. The voltage last applied by the DAC is retained by the combined capacitance of the trap electrode and an RC filter(R = 1 kΩ, C = 560 pF) placed within the vacuum apparatus.
Extended Data Fig. 5 Trap detachment. Schematic of the switch arrangement used to detach a trap electrode from the external DAC. Three MOSFET-based switches with an on-state resistance of 11 Ω and off-state capacitance Coff = 0.45 pF are chained and interleaved with capacitors C = 560 pF, forming capacitive dividers for improved isolation at radio frequencies. The voltage last applied by the DAC is retained by the combined capacitance of the trap electrode and an RC filter(R = 1 kΩ, C = 560 pF) placed within the vacuum apparatus.CC BY · PubMed Central

Verification

Claims the paper makes

13 Valid · 2 Not valid · 9 Not checked · 47 Own results and interpretations

38 more claims

Create a free account to see all 71 claims and to verify the 14 references still open.

See all claims — free account
  • Probably not a substantial claim. 14
  • It may state two separate claims as one. 16
  • Borderline: one of the tests for a substantial claim is unclear. 1
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 88 references

Cited by

See all 33

Metadata

Authors
Jain, S., Sägesser, T., Hrmo, P., Torkzaban, C., Stadler, M., Oswald, R., Axline, C., Bautista-Salvador, A., Ospelkaus, C., Kienzler, D., & Home, J.
Affiliations
  • ETH Zurich (CH)
  • Leibniz University Hannover (DE)
Corresponding author
Jain, Shreyans
Venue
Nature
Published
2024-03-13
Volume
627
Issue
8004
Pages
510-514
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4392762830
Cited by
33
References
88
Citations by year
2026: 10 · 2025: 14 · 2024: 9
FWCI
4.85
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
  • RePEc: Research Papers in Economics (submittedVersion)
  • arXiv (Cornell University)
Funders
  • European Commission (801285, 820495, EU-H2020, HORIZON2020, H2020, H2020 FET, H2020-FETFLAG-2018-03)
  • Deutsche Forschungsgemeinschaft (CRC 1227)
  • Eidgenössische Technische Hochschule Zürich
  • Horizon 2020 Framework Programme (EU‐H2020, 801285, 818195, 820495, H2020-FETFLAG-2018-03)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
Keywords
Penning ion trap, trapped-ion quantum computing, magnetic trapping, ion transport, quantum charge-coupled device, quantum simulation, quantum sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash and gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Penning micro-trap for quantum computing. https://app.cochat.ai/papers/10.1038/s41586-024-07111-x
The paper
Jain, S., Sägesser, T., Hrmo, P., Torkzaban, C., Stadler, M., Oswald, R., Axline, C., Bautista-Salvador, A., Ospelkaus, C., Kienzler, D., & Home, J. (2024). Penning micro-trap for quantum computing. Nature. https://doi.org/10.1038/s41586-024-07111-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.