Abstract

We present the design, fabrication and experimental implementation of surface ion traps with Y-shaped junctions. The traps are designed to minimize the pseudopotential variations in the junction region at the symmetric intersection of three linear segments. We experimentally demonstrate robust linear and junction shuttling with greater than 10 6 round-trip shuttles without ion loss. By minimizing the direct line of sight between trapped ions and dielectric surfaces, negligible day-to-day and trap-to-trap variations are observed. In addition to high-fidelity single-ion shuttling, multiple-ion chains survive splitting, ion-position swapping and recombining routines. The development of two-dimensional trapping structures is an important milestone for ion-trap quantum computing and quantum simulations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1367-2630/13/7/075018

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Figure 1 Scanning electron microscope (SEM) image of a YH-junction trap. In each trap, 47 independent dc electrodes are routed for wire bonding to the ceramic pin grid array (CPGA). The rf electrodes are ≈ 42 . 5 µ m wide with a nominal center-to-center spacing of ≈ 142 . 9 µ m. All gaps between electrodes are 7 µ m. Inset: image of seven ions trapped above the loading hole. The average ion-ion spacing in this image is ≈ 3 . 5 µ m.
Figure 1 Scanning electron microscope (SEM) image of a YH-junction trap. In each trap, 47 independent dc electrodes are routed for wire bonding to the ceramic pin grid array (CPGA). The rf electrodes are ≈ 42 . 5 µ m wide with a nominal center-to-center spacing of ≈ 142 . 9 µ m. All gaps between electrodes are 7 µ m. Inset: image of seven ions trapped above the loading hole. The average ion-ion spacing in this image is ≈ 3 . 5 µ m.CC-BY · From the PDF
Figure 2 SEM image of the central region of the YH-junction trap (left) and the YL-junction trap (right). Note especially the sharp edges in YH that are rounded in YL.
Figure 2 SEM image of the central region of the YH-junction trap (left) and the YL-junction trap (right). Note especially the sharp edges in YH that are rounded in YL.CC-BY · From the PDF
Figure 3 Left: BE simulation of the trap pseudopotential from the junction center ( x = 0 µ m) outward along a linear segment of the YH trap. The loading hole is centered at x = 853 µ m. Right: height of the pseudopotential minimum above the trap surface as a function of x . The minimum of the pseudopotential follows this trajectory. The lateral position perpendicular to the trap axis does not vary significantly from zero.
Figure 3 Left: BE simulation of the trap pseudopotential from the junction center ( x = 0 µ m) outward along a linear segment of the YH trap. The loading hole is centered at x = 853 µ m. Right: height of the pseudopotential minimum above the trap surface as a function of x . The minimum of the pseudopotential follows this trajectory. The lateral position perpendicular to the trap axis does not vary significantly from zero.CC-BY · From the PDF
Figure 4 SEM image showing the detail of the loading hole and the modulated edges of nearby electrodes.
Figure 4 SEM image showing the detail of the loading hole and the modulated edges of nearby electrodes.CC-BY · From the PDF
Figure 5 Left: direct image of the ion (upper) and indirect image of the ion reflected by the aluminum trap surface (lower). Right: elapsed-time image of an ion shuttling ≈ 40 µ m up each arm in a YH trap. This 10 s image captures ≈ 40 000 round-trip junction shuttles. Rather than shuttling into the exact center of the junction, the ions are intentionally steered along a smooth path between the linear sections.
Figure 5 Left: direct image of the ion (upper) and indirect image of the ion reflected by the aluminum trap surface (lower). Right: elapsed-time image of an ion shuttling ≈ 40 µ m up each arm in a YH trap. This 10 s image captures ≈ 40 000 round-trip junction shuttles. Rather than shuttling into the exact center of the junction, the ions are intentionally steered along a smooth path between the linear sections.CC-BY · From the PDF
Figure 6 Left: ions within the same harmonic well separated by approximately 6 µ m. Right: ions separated by four electrodes (approximately 370 µ m). The splitting and recombining of two ions was explicitly observed hundreds of times without error.
Figure 6 Left: ions within the same harmonic well separated by approximately 6 µ m. Right: ions separated by four electrodes (approximately 370 µ m). The splitting and recombining of two ions was explicitly observed hundreds of times without error.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 95

Metadata

Authors
Moehring, D. L., Highstrete, C., Stick, D., Fortier, K. M., Haltli, R., Tigges, C., & Blain, M. G.
Affiliations
Sandia National Laboratories (US)
Corresponding author
Highstrete, C
Venue
New Journal of Physics
Published
2011-07-29
Volume
13
Issue
7
Pages
075018
ISSN
1367-2630 (ISSN-L)
OpenAlex
W2120080758
Cited by
93
References
25
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 3 · 2019: 11 · 2018: 6 · 2017: 8 · 2016: 4 · 2015: 6 · 2014: 10 · 2013: 13 · 2012: 7
FWCI
10.02
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • New Journal of Physics (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University) (public-domain)
Funders
  • U.S. Department of Energy (DE–AC04–94AL85000, AC04-94AL85000)
  • National Nuclear Security Administration (DE-AC04- 94AL85000)
  • Intelligence Advanced Research Projects Activity
  • Sandia National Laboratories (94AL85000, DEAC04-94AL85000, AC04-94AL85000)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
Keywords
surface-electrode ion trap, Y-junction, pseudopotentials, ion shuttling, linear ion trap, ion trap quantum computing, quantum simulation, ion recombination

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design, fabrication and experimental demonstration of junction surface ion traps. https://app.cochat.ai/papers/10.1088/1367-2630/13/7/075018
The paper
Moehring, D. L., Highstrete, C., Stick, D., Fortier, K. M., Haltli, R., Tigges, C., & Blain, M. G. (2011). Design, fabrication and experimental demonstration of junction surface ion traps. New Journal of Physics. https://doi.org/10.1088/1367-2630/13/7/075018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.