Tailoring cryo-electron microscopy grids by photo-micropatterning for in-cell structural studies
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Spatially controlled cell adhesion on electron microscopy supports remains a bottleneck in specimen preparation for cellular cryo-electron tomography. Here, we describe contactless and mask-free photo-micropatterning of electron microscopy grids for site-specific deposition of extracellular matrix-related proteins. We attained refined cell positioning for micromachining by cryo-focused ion beam milling. Complex micropatterns generated predictable intracellular organization, allowing direct correlation between cell architecture and in-cell three-dimensional structural characterization of the underlying molecular machinery. Micropatterning of cryo-EM grids enables controlled adhesion of mammalian cells for cryo-ET-based structural studies. This approach leads to reproducible cellular morphology and improves focused ion beam thinning of cells for in-cell structural analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Micropatterning as a tool to decipher cell morphogenesis and functions
Théry, M. (2010) · Journal of Cell Science · doi:10.1242/jcs.075150 · Cited by 730
Self-citationSite-specific cryo-focused ion beam sample preparation guided by 3D correlative microscopy
Arnold, J., Mahamid, J., Lucic, V., de Marco, A., Fernandez, J.-J., Laugks, T., Mayer, T., Hyman, A. A., Baumeister, W., & Plitzko, J. M. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2015.10.053 · Cited by 221
Self-citationThe Human Nuclear Pore Complex as Revealed by Cryo-Electron Tomography
Maimon, T., Elad, N., Dahan, I., & Medalia, O. (2012) · Structure · doi:10.1016/j.str.2012.03.025 · Cited by 196
Cited by
The promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
The In Situ Structure of Parkinson’s Disease-Linked LRRK2
Watanabe, R., Buschauer, R., Böhning, J., Audagnotto, M., Lasker, K., Lu, T.-W., Boassa, D., Taylor, S., & Villa, E. (2020) · Cell · doi:10.1016/j.cell.2020.08.004 · Cited by 207
Preparing samples from whole cells using focused-ion-beam milling for cryo-electron tomography
Wagner, F. R., Watanabe, R., Schampers, R., Singh, D., Persoon, H., Schaffer, M., Fruhstorfer, P., Plitzko, J., & Villa, E. (2020) · Nature Protocols · doi:10.1038/s41596-020-0320-x · Cited by 195
Mind the gap: Micro-expansion joints drastically decrease the bending of FIB-milled cryo-lamellae
Wolff, G., Limpens, R. W. A. L., Zheng, S., Snijder, E. J., Agard, D. A., Koster, A. J., & Bárcena, M. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.09.006 · Cited by 115
Recent advances in gene therapy for neurodevelopmental disorders with epilepsy
Turner, T. J., Zourray, C., Schorge, S., & Lignani, G. (2021) · Journal of Neurochemistry · doi:10.1111/jnc.15168 · Cited by 71
Metadata
- Authors
- Toro-Nahuelpan, M., Zagoriy, I., Senger, F., Blanchoin, L., Théry, M., & Mahamid, J.
- Venue
- Nature Methods
- Published
- 2019-11-18
- Volume
- 17
- Issue
- 1
- Pages
- 50-54
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2982838216
- Cited by
- 120
- References
- 4
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.