CoChat

High-resolution structural and functional deep brain imaging using adaptive optics three-photon microscopy

Open access
Streich, Lina, Boffi, Juan Carlos, Wang, Ling, Alhalaseh, Khaleel, Barbieri, Matteo, Rehm, Ronja, Deivasigamani, Senthilkumar, Gross, Cornelius T., Agarwal, Amit, Prevedel, Robert · 2021 · Nature Methods
Cited by 185

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Multiphoton microscopy has become a powerful tool with which to visualize the morphology and function of neural cells and circuits in the intact mammalian brain. However, tissue scattering, optical aberrations and motion artifacts degrade the imaging performance at depth. Here we describe a minimally invasive intravital imaging methodology based on three-photon excitation, indirect adaptive optics (AO) and active electrocardiogram gating to advance deep-tissue imaging. Our modal-based, sensorless AO approach is robust to low signal-to-noise ratios as commonly encountered in deep scattering tissues such as the mouse brain, and permits AO correction over large axial fields of view. We demonstrate near-diffraction-limited imaging of deep cortical spines and (sub)cortical dendrites up to a depth of 1.4 mm (the edge of the mouse CA1 hippocampus). In addition, we show applications to deep-layer calcium imaging of astrocytes, including fibrous astrocytes that reside in the highly scattering corpus callosum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41592-021-01257-6

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

  • Live-cell imaging powered by computation

    Shroff, H., Testa, I., Jug, F., & Manley, S. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00702-6 · Cited by 75

    “…sensing tends to be faster, while indirect methods are better suited to imaging in opaque tissue; both have been applied to substantially improve image quality in live imaging studies conducted with confocal 70 , light-sheet 71 , multiphoton 72,73 and structured illumination 74,75 microscopy.”

See all 185

Metadata

Authors
Streich, L., Boffi, J. C., Wang, L., Alhalaseh, K., Barbieri, M., Rehm, R., Deivasigamani, S., Gross, C. T., Agarwal, A., & Prevedel, R.
Venue
Nature Methods
Published
2021-09-30
Volume
18
Issue
10
Pages
1253-1258
ISSN
  • 1548-7091 (ISSN-L)
  • 1548-7105
OpenAlex
W3176940597
Cited by
185
References
7
FWCI
11.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-resolution structural and functional deep brain imaging using adaptive optics three-photon microscopy. https://app.cochat.ai/papers/10.1038/s41592-021-01257-6
The paper
Streich, L., Boffi, J. C., Wang, L., Alhalaseh, K., Barbieri, M., Rehm, R., Deivasigamani, S., Gross, C. T., Agarwal, A., & Prevedel, R. (2021). High-resolution structural and functional deep brain imaging using adaptive optics three-photon microscopy. Nature Methods. https://doi.org/10.1038/s41592-021-01257-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.