The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)
Open accessAbstract
Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membranes. Temporal studies were performed using both infrared spectroscopic, dynamic light scattering, and impedimetric spectroscopy to demonstrate stability in detection of analytes, Interleukin-6 (IL-6) and Cortisol, from human sweat in RTILs. Temporal stability in sensor performance was performed as follows: (a) detection of target analytes after 0, 24, 48, 96, and 168 hours post-antibody sensor functionalization; and (b) continuous detection of target analytes post-antibody sensor functionalization. Limit of detection of IL-6 in human sweat was 0.2 pg/mL for 0–24 hours and 2 pg/mL for 24–48 hours post-antibody sensor functionalization. Continuous detection of IL-6 over 0.2–200 pg/mL in human sweat was demonstrated for a period of 10 hours post-antibody sensor functionalization. Furthermore, combinatorial detection of IL-6 and Cortisol in human sweat was established with minimal cross-talk for 0–48 hours post-antibody sensor functionalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, a wearable immunosensor for detecting cortisol and interleukin 6 (IL-6) in sweat has diagnostic potential (Fig. 3g)43.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [43]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Limit of blank, limit of detection and limit of quantitation.
Armbruster, D., & Pry, T. (2008) · PubMed Central · doi:10.1111/aji.13807 · Cited by 2,092
Inflammation, obesity, stress and coronary heart disease: is interleukin-6 the link?
Yudkin, J. S., Kumari, M., Humphries, S. E., & Mohamed-Ali, V. (2000) · Atherosclerosis · doi:10.1016/s0021-9150(99)00463-3 · Cited by 1,775
van Rantwijk, F., & Sheldon, R. A. (2007) · Chemical Reviews · doi:10.1021/cr050946x · Cited by 1,573
Ionic Liquids at Electrified Interfaces
Fedorov, M. V., & Kornyshev, A. A. (2014) · Chemical Reviews · doi:10.1021/cr400374x · Cited by 1,413
Bankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,304
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2012) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 816
Analytical applications of room-temperature ionic liquids: A review of recent efforts
Pandey, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.038 · Cited by 761
Sheldon, R. A., Lau, R. M., Sorgedrager, M. J., van Rantwijk, F., & Seddon, K. R. (2002) · Green Chemistry · doi:10.1039/b110008b · Cited by 737
Applications of ionic liquids in electrochemical sensors
Wei, D., & Ivaska, A. U. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.011 · Cited by 726
Cited by
Sorted by citations
Items 101–149 of 149
The Potential Role of Ionic Liquid as a Multifunctional Dental Biomaterial
Hossain, M. I., Shams, A. B., Gupta, S. D., Blanchard, G. J., Mobasheri, A., & Apu, E. H. (2023) · Biomedicines · doi:10.3390/biomedicines11113093 · Cited by 8
Lee, S., Lee, J., & Kang, S. H. (2023) · The Analyst · doi:10.1039/d2an01734b · Cited by 8
Integrated Sensing Arrays Based on Organic Electrochemical Transistors
Wen, J., Xu, J., Huang, W., Chen, C., Bai, L., & Cheng, Y. (2022) · IEEE Open Journal of Nanotechnology · doi:10.1109/ojnano.2022.3215135 · Cited by 7
Gubin, D. G. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781839167553-00536 · Cited by 7
Dhamu, V. N., Paul, A., Muthukumar, S., & Prasad, S. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abe8e9 · Cited by 6
Self-citationMeira, D. I., Barbosa, A. I., Proença, M., Pereira‐Silva, P., Borges, J., Correlo, V. M., Reis, R. L., & Vaz, F. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad60d7 · Cited by 6
Wang, B., Wilhelm, A., Wilhelm, A., Pilehvar, S., Moshfeghi, S., Stout, P., Salahi, K., & Emaminejad, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00003-5 · Cited by 6
Combinatorial Sensors: An Integrated Approach to Lifestyle Management and Environmental Surveillance
Dhamu, V. N., Banga, I. K., Paul, A., Ganguly, A., Bhide, A., Telang, C., Muthukumar, S., & Prasad, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00044-3 · Cited by 6
Self-citationMetal‐oxide Semiconductors for Noninvasive Diagnosis of Breast Cancer
Velumani, M., Banga, I. K., Paul, A., Prasanth, A., Meher, S. R., Rufus, E., Muthukumar, S., Prasad, S., & Alex, Z. C. (2022) · Wiley eBooks · doi:10.1002/9783527824229.ch8 · Cited by 6
Self-citationJanardhanan, J. A., She, J.-W., & Yu, H. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c01229 · Cited by 5
Surface Biochemical Modification of Poly(dimethylsiloxane) for Specific Immune Cytokine Response
Laborie, E., Bayle, F., Bouville, D., Smadja, C., Dufour‐Gergam, E., & Ammar, M. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01188 · Cited by 5
Mathew, M. T., Chaudhary, T., Jacobs, M., Bijukumar, D. R., Wimmer, M. A., Hallab, N. J., Jacobs, J. J., & Prasad, S. (2018) · Journal of Bio- and Tribo-Corrosion · doi:10.1007/s40735-018-0188-2 · Cited by 5
Self-citationRegalia, G., Resnati, D., & Tognetti, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00130-8 · Cited by 9
Ganguly, A., Basu, U., Gunda, V., Krishnan, A., Ramesh, P., Jivnani, K., Raghuram, A., Bhagavatula, S., Khan, S. A., Zimmern, P. E., et al. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70038 · Cited by 4
Self-citationReview—Electrochemical Immunosensors for Depression Markers Detection: Development in Recent Years
Guo, M., Chen, Y., Mo, X., Wei, H., Li, Y., Jia, Y., Hu, F., & Du, Y. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad1c79 · Cited by 5
Battery-less lactate monitoring system using a non-enzymatic sensor with selectivity
Lin, S., Lefeuvre, É., & Wang, H.-Y. A. (2024) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2024.105393 · Cited by 4
Paul, A., Muthukumar, S., & Prasad, S. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abba8f · Cited by 4
Self-citationCosta‐Rama, E., & Fernández-Abedul, M. T. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00008-2 · Cited by 6
Sensor Ecosystems for Health Self‐Monitoring: Focus on Diabetes Management
Ganguly, A., Churcher, N. K. M., Upasham, S., Dhamu, V. N., & Prasad, S. (2023) · Wiley eBooks · doi:10.1002/9783527834266.ch44 · Cited by 4
Self-citationAn analytical review of biosensor-based chronic pain quantification in healthcare
Kannan, A., West, D. W. D., Kumbhare, D. A., Ting, W., Ali, M. Y., Kawsar, H. I., Singh, G., Shanthanna, H., Hapidou, E. G., & Howlader, M. M. R. (2025) · Healthcare Analytics · doi:10.1016/j.health.2025.100419 · Cited by 3
From lab to field: progress and prospect of sweat sensing technology in sports monitoring
Gao, N., Deng, X., Lei, Y., Jiang, P., & Wu, Y. (2026) · Microchimica Acta · doi:10.1007/s00604-026-07835-9 · Cited by 3
Colmena-Rubil, V., Zuaznabar‐Gardona, J. C., Muñoz‐Berbel, X., Aznar‐Cervantes, S. D., Muñoz‐Berbel, X., & Guirado, G. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118949 · Cited by 3
Meander-gated dual cap GaN HEMT-based portable noninvasive COVID-19 detection platform
Thakur, R. R., Saini, A. K., Taliyan, R., & Chaturvedi, N. (2024) · Applied Physics Letters · doi:10.1063/5.0198047 · Cited by 3
Shahub, S., Ramasubramanya, A. H., Singh, P., Kumar, R. M., Lin, K., Muthukumar, S., & Prasad, S. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100622 · Cited by 3
Self-citationFLOCK -flare clock: Passive sweat-based eczematous flare detection system
Upasham, S., Rice, P., Pali, M. L., & Prasad, S. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100120 · Cited by 4
Self-citationBiocompatible Sensors Are Revolutionizing Healthcare Technologies
Yang, Q., Jin, W., Lu, T., Liu, S., Yin, J., Zhou, T., & Ren, T. (2022) · Springer eBooks · doi:10.1007/978-981-16-9897-2_10 · Cited by 3
Identification of end‐stage renal disease metabolic signatures from human perspiration
Shankar, V., Michael, B., Celli, A., Zhou, Z., Ashland, M. D., Tibshirani, R. J., Snyder, M. P., & Zare, R. N. (2023) · Natural Sciences · doi:10.1002/ntls.20220048 · Cited by 3
Yaman, Y. T., & Abacı, S. (2022) · Düzce Üniversitesi Bilim ve Teknoloji Dergisi · doi:10.29130/dubited.1003867 · Cited by 1
Innovative Biomedical and Clinical Approaches in Ionic Liquids, Nanofluids, and Nanoparticles
Ashwini, A. (2026) · Lecture notes in nanoscale science and technology · doi:10.1007/978-3-032-04008-4_8 · Cited by 1
Zhang, Y., Zhong, B., Yuan, Y., Xu, K., Yu, Y., Lou, Z., & Wang, L. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502662 · Cited by 2
Rahman, M. S., Rahman, H., Alam, F., Huq, H. F., Islam, N., & Jalal, A. H. (2026) · Biosensors and Biomolecular Electronics · doi:10.1186/s44510-026-00010-7 · Cited by 1
Sankhala, D., Rice, P., Muthukumar, S., & Prasad, S. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180901 · Cited by 1
Self-citationWatkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Yan, R., Lakshmipriya, T., Gopinath, S. C. B., Ismail, I., Subramanıam, S., & Chen, Y. (2025) · Arabian Journal of Chemistry · doi:10.25259/ajc_123_2024 · Cited by 1
Emerging wearable technologies for personalized health and performance monitoring
Emaminejad, S., Pilehvar, S., Wilhelm, A., Wilhelm, A., & King, K. (2018) · Micro- and Nanotechnology Sensors, Systems, and Applications · doi:10.1117/12.2305693 · Cited by 1
Electrochemical Wearable Devices
Lee, B. H., & Daniele, M. A.-A. (2021) · Wiley eBooks · doi:10.1002/9783527610426.bard030113 · Cited by 1
Lu, Y., & Guo, W. (2021) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.739247947.793582503
Effect of Ionic Liquids on Electrochemical Biosensors and Other Bioelectrochemical Devices
Borah, H., Dutta, U., & Dutta, R. R. (2023) · doi:10.1002/9783527839520.ch8
Electrochemical analysis of biological fluids
Brown, M. S., Kelly, M., & Koh, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99147-6.00003-x
Skin-derived biofluid sampling for analytical approaches
Sekine, Y., & Oikawa, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00034-5
Future applications of contact lenses
Phan, C., Walsh, K., & Jones, L. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-87929-3.00034-7
Huang, X., Jiao, Y., Yang, Y., & Li, J. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch2
Development of a selective and energy-autonomous lactic acid monitoring system
Lin, S.-H. (2024) · theses.fr (ABES) · doi:10.70675/4cf84d2cz15b0z4e58z8e1fz23980ac846ec
Cai, H., He, Y. F., Wang, C., Zhao, Y., & Yang, C. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1885022 · Cited by 1
Zhu, L., Xie, X., Mao, X., Tao, M., Li, F., Gu, G., Wu, Z., & Liu, Y. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.119237
Kumar, A., Karmakar, S., Kothari, N. P., Giddaluru, S. G., Singh, P., Lin, K., Muthukumar, S., & Prasad, S. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.6c00139
Self-citationWearable sweat sensors for arthritis monitoring
Tiwari, A., Xu, B. B., & Zhang, X. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182747
Kavruk, M., Menfaatli, E., Kösemen, A., Öztürk, S., & Özalp, V. C. (2026) · Biosensors · doi:10.3390/bios16110604
Metadata
- Authors
- Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Prasad, Shalini
- Venue
- Scientific Reports
- Published
- 2017-05-16
- Volume
- 7
- Issue
- 1
- Pages
- 1950-1950
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5434046
- OpenAlex
- W2612250156
- Cited by
- 149
- References
- 46
- Citations by year
- 2026: 13 · 2025: 16 · 2024: 24 · 2023: 16 · 2022: 23 · 2021: 19 · 2020: 12 · 2019: 12 · 2018: 12 · 2017: 2
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, room temperature ionic liquids, interleukin-6 detection, cortisol detection, nanoporous membranes, sensor stability
- MeSH terms
- Dynamic Light Scattering, Wearable Electronic Devices, Humans, Hydrocortisone, Nylons, Sweat, Temperature, Zinc Oxide, Biosensing Techniques, Porosity, Spectroscopy, Fourier Transform Infrared, Ionic Liquids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review