The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)
Open accessAbstract
Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membranes. Temporal studies were performed using both infrared spectroscopic, dynamic light scattering, and impedimetric spectroscopy to demonstrate stability in detection of analytes, Interleukin-6 (IL-6) and Cortisol, from human sweat in RTILs. Temporal stability in sensor performance was performed as follows: (a) detection of target analytes after 0, 24, 48, 96, and 168 hours post-antibody sensor functionalization; and (b) continuous detection of target analytes post-antibody sensor functionalization. Limit of detection of IL-6 in human sweat was 0.2 pg/mL for 0–24 hours and 2 pg/mL for 24–48 hours post-antibody sensor functionalization. Continuous detection of IL-6 over 0.2–200 pg/mL in human sweat was demonstrated for a period of 10 hours post-antibody sensor functionalization. Furthermore, combinatorial detection of IL-6 and Cortisol in human sweat was established with minimal cross-talk for 0–48 hours post-antibody sensor functionalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, a wearable immunosensor for detecting cortisol and interleukin 6 (IL-6) in sweat has diagnostic potential (Fig. 3g)43.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [43]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Limit of blank, limit of detection and limit of quantitation.
Armbruster, D., & Pry, T. (2008) · PubMed Central · doi:10.1111/aji.13807 · Cited by 2,092
Inflammation, obesity, stress and coronary heart disease: is interleukin-6 the link?
Yudkin, J. S., Kumari, M., Humphries, S. E., & Mohamed-Ali, V. (2000) · Atherosclerosis · doi:10.1016/s0021-9150(99)00463-3 · Cited by 1,775
van Rantwijk, F., & Sheldon, R. A. (2007) · Chemical Reviews · doi:10.1021/cr050946x · Cited by 1,573
Ionic Liquids at Electrified Interfaces
Fedorov, M. V., & Kornyshev, A. A. (2014) · Chemical Reviews · doi:10.1021/cr400374x · Cited by 1,413
Bankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,304
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2012) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 816
Analytical applications of room-temperature ionic liquids: A review of recent efforts
Pandey, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.038 · Cited by 761
Sheldon, R. A., Lau, R. M., Sorgedrager, M. J., van Rantwijk, F., & Seddon, K. R. (2002) · Green Chemistry · doi:10.1039/b110008b · Cited by 737
Applications of ionic liquids in electrochemical sensors
Wei, D., & Ivaska, A. U. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.011 · Cited by 726
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 854
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. F. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 752
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2019) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2019.100523 · Cited by 391
Vo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 275
Metadata
- Authors
- Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Prasad, Shalini
- Venue
- Scientific Reports
- Published
- 2017-05-16
- Volume
- 7
- Issue
- 1
- Pages
- 1950-1950
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5434046
- OpenAlex
- W2612250156
- Cited by
- 149
- References
- 46
- Citations by year
- 2026: 13 · 2025: 16 · 2024: 24 · 2023: 16 · 2022: 23 · 2021: 19 · 2020: 12 · 2019: 12 · 2018: 12 · 2017: 2
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, room temperature ionic liquids, interleukin-6 detection, cortisol detection, nanoporous membranes, sensor stability
- MeSH terms
- Dynamic Light Scattering, Wearable Electronic Devices, Humans, Hydrocortisone, Nylons, Sweat, Temperature, Zinc Oxide, Biosensing Techniques, Porosity, Spectroscopy, Fourier Transform Infrared, Ionic Liquids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review