The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)
Open accessAbstract
Successful commercialization of wearable diagnostic sensors necessitates stability in detection of analytes over prolonged and continuous exposure to sweat. Challenges are primarily in ensuring target disease specific small analytes (i.e. metabolites, proteins, etc.) stability in complex sweat buffer with varying pH levels and composition over time. We present a facile approach to address these challenges using RTILs with antibody functionalized sensors on nanoporous, flexible polymer membranes. Temporal studies were performed using both infrared spectroscopic, dynamic light scattering, and impedimetric spectroscopy to demonstrate stability in detection of analytes, Interleukin-6 (IL-6) and Cortisol, from human sweat in RTILs. Temporal stability in sensor performance was performed as follows: (a) detection of target analytes after 0, 24, 48, 96, and 168 hours post-antibody sensor functionalization; and (b) continuous detection of target analytes post-antibody sensor functionalization. Limit of detection of IL-6 in human sweat was 0.2 pg/mL for 0–24 hours and 2 pg/mL for 24–48 hours post-antibody sensor functionalization. Continuous detection of IL-6 over 0.2–200 pg/mL in human sweat was demonstrated for a period of 10 hours post-antibody sensor functionalization. Furthermore, combinatorial detection of IL-6 and Cortisol in human sweat was established with minimal cross-talk for 0–48 hours post-antibody sensor functionalization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, a wearable immunosensor for detecting cortisol and interleukin 6 (IL-6) in sweat has diagnostic potential (Fig. 3g)43.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [43]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Limit of blank, limit of detection and limit of quantitation.
Armbruster, D., & Pry, T. (2008) · PubMed Central · doi:10.1111/aji.13807 · Cited by 2,092
Inflammation, obesity, stress and coronary heart disease: is interleukin-6 the link?
Yudkin, J. S., Kumari, M., Humphries, S. E., & Mohamed-Ali, V. (2000) · Atherosclerosis · doi:10.1016/s0021-9150(99)00463-3 · Cited by 1,775
van Rantwijk, F., & Sheldon, R. A. (2007) · Chemical Reviews · doi:10.1021/cr050946x · Cited by 1,573
Ionic Liquids at Electrified Interfaces
Fedorov, M. V., & Kornyshev, A. A. (2014) · Chemical Reviews · doi:10.1021/cr400374x · Cited by 1,413
Bankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,304
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2012) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 816
Analytical applications of room-temperature ionic liquids: A review of recent efforts
Pandey, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.038 · Cited by 761
Sheldon, R. A., Lau, R. M., Sorgedrager, M. J., van Rantwijk, F., & Seddon, K. R. (2002) · Green Chemistry · doi:10.1039/b110008b · Cited by 737
Applications of ionic liquids in electrochemical sensors
Wei, D., & Ivaska, A. U. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.011 · Cited by 726
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 854
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. F. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 752
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2019) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2019.100523 · Cited by 391
Vo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 275
Portable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231
Self-citationWearable Chemical Sensors: Emerging Systems for On-Body Analytical Chemistry
Sempionatto, J. R., Jeerapan, I., Krishnan, S., & Wang, J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04668 · Cited by 235
Basatneh, R., Najafi, B., & Armstrong, D. G. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818768618 · Cited by 196
Keene, S. T., Fogarty, D., Cooke, R., Casadevall, C., Salleo, A., & Parlak, O. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201901321 · Cited by 185
Lu, T., Ji, S., Jin, W., Yang, Q., Luo, Q., & Ren, T. (2023) · Sensors · doi:10.3390/s23062991 · Cited by 183
Flexible plastic, paper and textile lab-on-a chip platforms for electrochemical biosensing
Economou, A., Kokkinos, C., & Prodromidis, M. I. (2018) · Lab on a Chip · doi:10.1039/c8lc00025e · Cited by 144
Nanobiosensors: Point-of-care approaches for cancer diagnostics
Shandilya, R., Bhargava, A., Bunkar, N., Tiwari, R. R., Goryacheva, I. Y., & Mishra, P. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.034 · Cited by 137
Recent Advances in Portable Biosensors for Biomarker Detection in Body Fluids
Senf, B., Yeo, W., & Kim, J. (2020) · Biosensors · doi:10.3390/bios10090127 · Cited by 133
Tuteja, S., Ormsby, C., & Neethirajan, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0193-5 · Cited by 119
Tanak, A. S., Jagannath, B., Tamrakar, Y., Muthukumar, S., & Prasad, S. (2019) · Analytica Chimica Acta X · doi:10.1016/j.acax.2019.100029 · Cited by 118
Self-citationSweat as a Source of Next-Generation Digital Biomarkers
Brasier, N., & Eckstein, J. (2019) · Digital Biomarkers · doi:10.1159/000504387 · Cited by 120
Poudineh, M., Maikawa, C. L., Ma, Y., Pan, J., Mamerow, D., Hang, Y., Baker, S. W., Beirami, A., Yoshikawa, A. M., Eisenstein, M. S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00661-1 · Cited by 117
Review—Energy Autonomous Wearable Sensors for Smart Healthcare: A Review
Dahiya, A. S., Thireau, J., Boudaden, J., Lal, S., Gulzar, U., Zhang, Y., Gil, T., Azémard, N., Ramm, P., Kiessling, T., et al. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0162003jes · Cited by 107
Hao, Z., Wang, Z., Li, Y., Zhu, Y., Wang, X., Moraes, C. G. D., Pan, Y., Zhao, X., & Lin, Q. (2018) · Nanoscale · doi:10.1039/c8nr04315a · Cited by 107
Jagannath, B., Lin, K., Pali, M. L., Sankhala, D., Muthukumar, S., & Prasad, S. (2021) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10220 · Cited by 104
Self-citationBCLA CLEAR – Contact lens technologies of the future
Jones, L., Hui, A., Phan, C., Read, M., Azar, D. T., Buch, J. R., Ciolino, J. B., Naroo, S. A., Pall, B., Romond, K., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.007 · Cited by 104
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96
Thermotropic Liquid Crystal-Assisted Chemical and Biological Sensors
Popov, N. I., Honaker, L. W., Popova, M., Usol'tseva, N. V., Mann, E. K., Jákli, A. I., & Popov, P. (2017) · Materials · doi:10.3390/ma11010020 · Cited by 97
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Upasham, S., Banga, I. K., Jagannath, B., Paul, A., Lin, K., Muthukumar, S., & Prasad, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112940 · Cited by 86
Self-citationA machine learning-based on-demand sweat glucose reporting platform
Sankhala, D., Sardesai, A. U., Pali, M. L., Lin, K., Jagannath, B., Muthukumar, S., & Prasad, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-06434-x · Cited by 84
Self-citationFlexible, wearable biosensors for digital health
Zhu, P., Peng, H., & Rwei, A. Y. (2022) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2022.100118 · Cited by 72
Thakur, A., & Kumar, A. (2023) · Results in Engineering · doi:10.1016/j.rineng.2023.101533 · Cited by 65
CortiWatch: Watch-Based Cortisol Tracker
Rice, P., Upasham, S., Jagannath, B., Manuel, R., Pali, M., & Prasad, S. (2019) · Future Science OA · doi:10.2144/fsoa-2019-0061 · Cited by 63
Self-citationPérez, D., & Orozco, J. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05228-2 · Cited by 67
Khan, M. S., Dighe, K., Wang, Z., Srivastava, I., Schwartz‐Duval, A. S., Misra, S. K., & Pan, D. (2018) · The Analyst · doi:10.1039/c8an02085j · Cited by 63
Qureshi, A., & Niazi, J. H. (2023) · Materials Horizons · doi:10.1039/d2mh01517j · Cited by 63
Clinical applications of smart wearable sensors
Tao, Q., Liu, S., Zhang, J., Jiang, J., Jin, Z., Huang, Y., Liu, X., Lin, S., Zeng, X., Li, X., et al. (2023) · iScience · doi:10.1016/j.isci.2023.107485 · Cited by 65
Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids
Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020) · Sensors · doi:10.3390/s20216352 · Cited by 62
Cortisol Immunosensors: A Literature Review
Karachaliou, C., Koukouvinos, G., Goustouridis, D., Raptis, I., Kakabakos, S. E., Petrou, P. S., & Livaniou, E. (2023) · Biosensors · doi:10.3390/bios13020285 · Cited by 63
Jagannath, B., Muthukumar, S., & Prasad, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.013 · Cited by 56
Self-citationCATCH (Cortisol Apta WATCH): ‘Bio-mimic alarm’ to track Anxiety, Stress, Immunity in human sweat
Pali, M. L., Jagannath, B., Lin, K., Upasham, S., Sankhalab, D., Upashama, S., Muthukumar, S., & Prasad, S. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.138834 · Cited by 56
Self-citationDevelopment of a flexible, sweat-based neuropeptide Y detection platform
Churcher, N. K. M., Upasham, S., Rice, P., Bhadsavle, S., & Prasad, S. (2020) · RSC Advances · doi:10.1039/d0ra03729j · Cited by 56
Self-citationHao, Z., Pan, Y., Huang, C., Wang, Z., & Zhao, X. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0409-6 · Cited by 52
Rapid and Selective Biomarker Detection with Conductometric Sensors
Perera, G. S., Ahmed, T., Heiss, L., Walia, S., Bhaskaran, M. C., & Sriram, S. (2021) · Small · doi:10.1002/smll.202005582 · Cited by 49
Development of ultra-low volume, multi-bio fluid, cortisol sensing platform
Upasham, S., Tanak, A., Jagannath, B., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-35199-5 · Cited by 50
Self-citationFlexible and stretchable inorganic optoelectronics
Li, H., Cao, Y. K., Wang, Z., & Feng, X. (2019) · Optical Materials Express · doi:10.1364/ome.9.004023 · Cited by 47
Hirten, R. P., Lin, K., Whang, J. K., Shahub, S., Helmus, D. S., Muthukumar, S., Sands, B. E., & Prasad, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-53522-1 · Cited by 47
Self-citationGnanasekaran, B., Umapathy, S., & Salvador, A. L. (2024) · Analytical Biochemistry · doi:10.1016/j.ab.2024.115578 · Cited by 44
Wearable biosensors for human fatigue diagnosis: A review
Zhang, J., Chen, M., Peng, Y., Li, S., Han, D., Ren, S., Qin, K., Li, S., Han, T., Wang, Y., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10318 · Cited by 44
Jagannath, B., Pali, M. L., Lin, K., Sankhala, D., Naraghi, P., Muthukumar, S., & Prasad, S. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202101356 · Cited by 39
Self-citationSLOCK (sensor for circadian clock): passive sweat-based chronobiology tracker
Upasham, S., & Prasad, S. (2020) · Lab on a Chip · doi:10.1039/d0lc00134a · Cited by 38
Self-citationRecent Advances in Two-Dimensional MXene-Based Electrochemical Biosensors for Sweat Analysis
Ganesan, S., Ramajayam, K., Kokulnathan, T., & Palaniappan, A. (2023) · Molecules · doi:10.3390/molecules28124617 · Cited by 37
Optical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 39
Noninvasive On-Skin Biosensors for Monitoring Diabetes Mellitus
Sedighi, A., Kou, T., Huang, H., & Li, Y. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01843-9 · Cited by 36
The Evolving Role of Proteins in Wearable Sweat Biosensors
Saldanha, D. J., Cai, A., & Courchesne, N. D. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00699 · Cited by 34
Ma, R., Shao, R., An, X., Zhang, Q., & Sun, S. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00749e · Cited by 34
Upasham, S., Bhide, A., Lin, K., & Prasad, S. (2020) · Future Science OA · doi:10.2144/fsoa-2020-0097 · Cited by 30
Self-citationYaman, Y. T., Vural, O. A., Bolat, G., & Abacı, S. (2022) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2022.108053 · Cited by 29
Zhao, G., Li, Z.-Y., Huang, X., Zhang, Q., Liu, Y., & Yu, X. (2024) · Soft Science · doi:10.20517/ss.2024.04 · Cited by 28
Design and Testing of Autonomous Chargeable and Wearable Sweat/Ionic Liquid‐Based Supercapacitors
Selvam, S., Park, Y., & Yim, J. (2022) · Advanced Science · doi:10.1002/advs.202201890 · Cited by 27
Passive Sweat-Based Pruritic Cytokine Detection and Monitoring System
Upasham, S., Rice, P., Shahub, S., Dhamu, V. N., & Prasad, S. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac82bc · Cited by 28
Self-citationElectrochemical Sensors for Cortisol: A Review
Naeem, A. N., Guldin, S., & Ghoreishizadeh, S. S. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3349293 · Cited by 29
Sensing patches for biomarker identification in skin-derived biofluids
Chen, W., Fu, D., Ma, T., Chen, M., Wang, F., Chen, G., & Wang, Z. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116326 · Cited by 27
Sayyad, P. W., Park, S., & Ha, T. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116407 · Cited by 27
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 34
Vigneshvar, S., & Senthilkumaran, B. (2018) · Medical Devices & Sensors · doi:10.1002/mds3.10011 · Cited by 26
Greyling, C. F., Ganguly, A., Sardesai, A. U., Churcher, N. K. M., Lin, K., Muthukumar, S., & Prasad, S. (2023) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1912 · Cited by 25
Self-citationSheffield, Z., Paul, P., Krishnakumar, S., & Pan, D. (2024) · Advanced Science · doi:10.1002/advs.202411339 · Cited by 24
Ploner, M., Shkodra, B., Franchin, L., Altana, A., Petrelli, M., Angeli, M. A. C., Ciccone, G., Antrack, T., Vanzetti, L., Nair, R. R., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117734 · Cited by 25
A comprehensive review on electrochemical cytokine detection in sweat
Ploner, M., Petrelli, M., Shkodra, B., Tagliaferri, A., Lugli, P., Resnati, D., Petti, L., & Angeli, M. A. C. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101985 · Cited by 23
Islam, M. A., Hassen, W., Tayabali, A. F., & Dubowski, J. J. (2021) · ACS Omega · doi:10.1021/acsomega.0c04753 · Cited by 21
Davis, B., Lin, K., Shahub, S., Ramasubramanya, A. H., Fagan, A., Muthukumar, S., Prasad, S., & Bajaj, J. S. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01404-1 · Cited by 21
Self-citationBiomarkers and detection methods of bipolar disorder
Hu, X., Yu, C., Dong, T., Yang, Z., Fang, Y., & Jiang, Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114842 · Cited by 21
Ganguly, A., Ebrahimzadeh, T., Zimmern, P. E., Nisco, N. J. D., & Prasad, S. (2021) · Chemosensors · doi:10.3390/chemosensors9090271 · Cited by 19
Self-citationLee, S., Lee, J., & Kang, S. H. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00752 · Cited by 19
Lenar, N., & Paczosa‐Bator, B. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26115001 · Cited by 19
Non-Invasive Wearables in Inflammation Monitoring: From Biomarkers to Biosensors
Wu, T., & Liu, G. (2025) · Biosensors · doi:10.3390/bios15060351 · Cited by 22
Singh, P., Kumar, A., Mishra, K. K., Lin, K., Muthukumar, S., & Prasad, S. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03728 · Cited by 18
Self-citationAdvances in Impedimetric Biosensors: Current Applications and Future Directions
Verma, A., Arqam, M., & Fraiwan, A. (2025) · Micromachines · doi:10.3390/mi16111244 · Cited by 18
Upasham, S., Osborne, O., & Prasad, S. (2021) · RSC Advances · doi:10.1039/d0ra10561a · Cited by 19
Self-citationFetal programming of human energy homeostasis brain networks: Issues and considerations
Rasmussen, J. M., Thompson, P. M., Entringer, S., Buß, C., & Wadhwa, P. D. (2021) · Obesity Reviews · doi:10.1111/obr.13392 · Cited by 20
Oh, D. Y., Na, H., Song, S. W., Kim, J., In, H., Lee, A. C., Jeong, Y., Lee, D., Jang, J., & Kwon, S. (2018) · Biomicrofluidics · doi:10.1063/1.5032170 · Cited by 18
Electrochemical Detection of Cancer Biomarkers: From Molecular Sensing to Clinical Translation
Nadeem-Tariq, A., Rafanan, J., Kang, N., Zhang, S., Kanniyappan, H., & Merchant, A. (2026) · Biosensors · doi:10.3390/bios16010044 · Cited by 17
Upasham, S., Bhadsavle, S., & Prasad, S. (2019) · Analytical Methods · doi:10.1039/c8ay02620c · Cited by 17
Self-citationBenjamin, M., Manoj, D., Karnan, M., Saravanakumar, D., Thenmozhi, K., Ariga, K., Sathish, M., & Senthilkumar, S. (2020) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2020.12.033 · Cited by 17
Noushin, T., & Tabassum, S. (2022) · doi:10.1117/12.2606248 · Cited by 16
Duke, K., Dhungana, P., Richards, C., Preusser, K., Romeo, A. A., Gonzalez‐Garcia, J., Mummareddy, B., Cortes, P., Li, F., & Park, B. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401040 · Cited by 15
Upasham, S., & Prasad, S. (2021) · ACS Omega · doi:10.1021/acsomega.1c02414 · Cited by 15
Self-citationLee, J., Lee, S., Lee, G., & Kang, S. H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114894 · Cited by 15
Fully Electronic Urine Dipstick Probe for Combinatorial Detection of Inflammatory Biomarkers
Kamakoti, V., Kinnamon, D., Choi, K. H., Jagannath, B., & Prasad, S. (2018) · Future Science OA · doi:10.4155/fsoa-2017-0142 · Cited by 14
Self-citationChen, C., Gopinath, S. C. B., & Anbu, P. (2021) · Nanoscale Research Letters · doi:10.1186/s11671-021-03527-w · Cited by 13
Kothari, A., Jagannath, B., Muthukumar, S., & Prasad, S. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100122 · Cited by 13
Self-citationElectrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Facure, M. H. M., Sampaio, B. S., Mercante, L. A., & Correa, D. S. (2024) · Materials Today Communications · doi:10.1016/j.mtcomm.2024.111197 · Cited by 12
Elgharbawy, A. A. M., Noor, N. M., Azmi, N. A. N., & Dewanti, B. S. D. (2026) · Molecules · doi:10.3390/molecules31020305 · Cited by 11
Sareło, P., Sobieszczańska, B., Wysokińska, E., Gąsior‐Głogowska, M., Kałas, W., Podbielska, H., Wawrzyńska, M., & Kopaczyńska, M. (2023) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2023.02.001 · Cited by 11
Transdermal drug delivery systems: Analysis of adhesion failure
Brooks, Z., Goswami, T., Neidhard-Doll, A. T., & Goswami, T. (2022) · Journal of Pharmaceutical and Biopharmaceutical Research · doi:10.25082/jpbr.2022.01.003 · Cited by 11
Progresses and Perspectives of 1D Soft Sensing Devices for Healthcare Applications
Kim, J., Kim, H.-J., Lee, M., Lee, J., Lee, Y., Kim, D., & Lee, J. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202406651 · Cited by 10
Organic ionic fluid-based wearable sensors for healthcare
Chen, Z., & Wang, Y. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00077f · Cited by 10
Noushin, T., Hossain, N. I., Tahrin, R., Islam, M. N., & Tabassum, S. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100772 · Cited by 10
Taylor, M. R., Knight, J. M., & Rosenberg, A. R. (2021) · Brain Behavior & Immunity - Health · doi:10.1016/j.bbih.2021.100321 · Cited by 9
Arias, Y. A. M., García, R. R., Agudelo, M. A. G., Pareja, N. M., & Orozco, C. P. O. (2024) · Materials Today Communications · doi:10.1016/j.mtcomm.2024.110109 · Cited by 8
Toward Reagentless and Universal Biomolecular Sensing: Molecular Pendulum-Based Bioanalysis
Wu, Z., Isaacson, S. E., Flynn, C. D., Das, J., & Kelley, S. O. (2025) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5c00573 · Cited by 8
Advances and Challenges in Wearable Sensors for Health Monitoring
Brazaca, L. C., Lozano, A. M., Mayol, B., Scheidt, D. T., Fazio, D. D., Kim, E., Maroli, G., Rosati, G., Ates, H. C., Wang, H., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04520 · Cited by 9
Metadata
- Authors
- Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Prasad, Shalini
- Venue
- Scientific Reports
- Published
- 2017-05-16
- Volume
- 7
- Issue
- 1
- Pages
- 1950-1950
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5434046
- OpenAlex
- W2612250156
- Cited by
- 149
- References
- 46
- Citations by year
- 2026: 13 · 2025: 16 · 2024: 24 · 2023: 16 · 2022: 23 · 2021: 19 · 2020: 12 · 2019: 12 · 2018: 12 · 2017: 2
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, room temperature ionic liquids, interleukin-6 detection, cortisol detection, nanoporous membranes, sensor stability
- MeSH terms
- Dynamic Light Scattering, Wearable Electronic Devices, Humans, Hydrocortisone, Nylons, Sweat, Temperature, Zinc Oxide, Biosensing Techniques, Porosity, Spectroscopy, Fourier Transform Infrared, Ionic Liquids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review