Beyond the Debye length in high ionic strength solution: direct protein detection with field-effect transistors (FETs) in human serum
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In this study, a new type of field-effect transistor (FET)-based biosensor is demonstrated to be able to overcome the problem of severe charge-screening effect caused by high ionic strength in solution and detect proteins in physiological environment. Antibody or aptamer-immobilized AlGaN/GaN high electron mobility transistors (HEMTs) are used to directly detect proteins, including HIV-1 RT, CEA, NT-proBNP and CRP, in 1X PBS (with 1%BSA) or human sera. The samples do not need any dilution or washing process to reduce the ionic strength. The sensor shows high sensitivity and the detection takes only 5 minutes. The designs of the sensor, the methodology of the measurement, and the working mechanism of the sensor are discussed and investigated. A theoretical model is proposed based on the finding of the experiments. This sensor is promising for point-of-care, home healthcare, and mobile diagnostic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436 · cited 1×
“The advantages and the features of our EDL AlGaN/GaN HEMTs include, (1) direct protein detection in physiological salt environment, such as in 1X PBS and human serum, (2) no dilution and no washing process, which will not affect protein activity and will be suitable for studying biological reactions in real-time, (3)…”
MethodElectrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782 · cited 1×
“The advantages and the features of our EDL AlGaN/GaN HEMTs include, (1) direct protein detection in physiological salt environment, such as in 1X PBS and human serum, (2) no dilution and no washing process, which will not affect protein activity and will be suitable for studying biological reactions in real-time, (3)…”
MethodChen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645 · cited 1×
“The advantages and the features of our EDL AlGaN/GaN HEMTs include, (1) direct protein detection in physiological salt environment, such as in 1X PBS and human serum, (2) no dilution and no washing process, which will not affect protein activity and will be suitable for studying biological reactions in real-time, (3)…”
MethodSelf-citationLabel-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543 · cited 1×
“The advantages and the features of our EDL AlGaN/GaN HEMTs include, (1) direct protein detection in physiological salt environment, such as in 1X PBS and human serum, (2) no dilution and no washing process, which will not affect protein activity and will be suitable for studying biological reactions in real-time, (3)…”
MethodElectric-double-layer field-effect transistors with ionic liquids
Fujimoto, T., & Awaga, K. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50755f · Cited by 392
C-reactive protein, inflammation and coronary heart disease
Shrivastava, A. K., Singh, H. V., Raizada, A., & Singh, S. K. (2015) · The Egyptian Heart Journal · doi:10.1016/j.ehj.2014.11.005 · Cited by 320
Yuan, H., Shimotani, H., Ye, J., Yoon, S., Aliah, H., Tsukazaki, A., Kawasaki, M., & Iwasa, Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja108912x · Cited by 271
Electric double-layer transistors: a review of recent progress
Du, H., Lin, X., Xu, Z., & Chu, D. (2015) · Journal of Materials Science · doi:10.1007/s10853-015-9121-y · Cited by 261
Detection beyond the Debye Screening Length in a High-Frequency Nanoelectronic Biosensor
Kulkarni, G. S., & Zhong, Z. (2012) · Nano Letters · doi:10.1021/nl203666a · Cited by 208 · cited 1×
“The advantages and the features of our EDL AlGaN/GaN HEMTs include, (1) direct protein detection in physiological salt environment, such as in 1X PBS and human serum, (2) no dilution and no washing process, which will not affect protein activity and will be suitable for studying biological reactions in real-time, (3)…”
Method
Research works printed but not linked: 10
- Kamalakar, M. V., Madhushankar, B. N., Dankert, A. & Dash, S. P. Effect of high-k dielectric and ionic liquid gate on nanolayer black-phosphorus field effect transistors. Applied Physics Letters 107, 113103 (2015). · doi:10.1063/1.4930236
- Ye, P. D. et al. GaN metal-oxide-semiconductor high-electron-mobility-transistor with atomic layer deposited Al2O3 as gate dielectric. Applied Physics Letters 86, 063501 (2005). · doi:10.1063/1.1861122
- Ohshima, H. Theory of Colloid and Interfacial Electric Phenomena, 1–38 (Elsevier, 2006).
- Holmes, D. L. & Stellwagen, N. C. The electric field dependence of DNA mobilities in agarose gels: A reinvestigation. Electrophoresis 11, 5–15 (1990). · doi:10.1002/elps.1150110103
- Jameson, E. & Alvarez-Tostado, C. A Study of Blood Serum Proteins by Electrophoresis. The Journal of Physical Chemistry 43, 1165–1172 (1939). · doi:10.1021/j150396a007
- Davis, A. J. et al. Human Immunodeficiency Virus type-1 reverse transcriptase exists as post-translationally modified forms in virions and cells. Retrovirology 5, 1–12 (2008). · doi:10.1186/1742-4690-5-115
- Casey, B. J. & Kofinas, P. Selective binding of carcinoembryonic antigen using imprinted polymeric hydrogels. Journal of Biomedical Materials Research Part A 87A, 359–363 (2008). · doi:10.1002/jbm.a.31757
- Tsujimoto, M., Inoue, K. & Nojima, S. Purification and Characterization of Human Serum C-Reactive Protein. Journal of Biochemistry 94, 1367–1373 (1983). · doi:10.1093/oxfordjournals.jbchem.a134483
- Long, H., Kudlay, A. & Schatz, G. C. Molecular Dynamics Studies of Ion Distributions for DNA Duplexes and DNA Clusters: Salt Effects and Connection to DNA Melting. The Journal of Physical Chemistry B 110, 2918–2926 (2006). · doi:10.1021/jp0556815
- Hsu, C.-P., Huang, Y.-F. & Wang, Y.-L. Investigation of the Non-Faradaic Current of DNA-Immobilized Microelectrodes in Concentrated Salt Environment for Biosensors. ECS Journal of Solid State Science and Technology 5, Q149–Q154 (2016). · doi:10.1149/2.0141606jss
Cited by
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Recent advances in biosensor for detection of lung cancer biomarkers
Yang, G., Xiao, Z., Tang, C., Deng, Y., Huang, H., & He, Z. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111416 · Cited by 330
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects
Vu, C.-A., & Chen, W.-Y. (2019) · Sensors · doi:10.3390/s19194214 · Cited by 238
“8 pg/mL, 1848 pg/mL, 3008 pg/mL, 4596 pg/mL and 5000 pg/mL [74,75,77].”
BackgroundSarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chen, P.-C., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Shiesh, S.-C., Lee, G.-B., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.018 · Cited by 169
Self-citationField-Effect Transistor Biosensor for Rapid Detection of Ebola Antigen
Chen, Y., Ren, R., Pu, H., Guo, X., Chang, J., Zhou, G., Mao, S., Kron, M., & Chen, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-11387-7 · Cited by 162
Self-citationExtended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158
Lin, S.-P., Lee, W.-J., Sun, M.-C., Yang, Y.-H., Vinzons, L. U., Lin, Y.-M., & Wei, Y.-T. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c12766 · Cited by 11
Metadata
- Authors
- Chu, C.-H., Sarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Chen, C.-C., Shiesh, S.-C., Lee, G.-B., & Wang, Y.-L.
- Venue
- Scientific Reports
- Published
- 2017-07-12
- Volume
- 7
- Issue
- 1
- Pages
- 5256-5256
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2731814899
- Cited by
- 245
- References
- 24
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.