CoChat

Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography

Open access
Mei, Kai, Schwaiger, Benedikt J., Kopp, Felix K., Ehn, Sebastian, Gersing, Alexandra S., Kirschke, Jan S., Muenzel, Daniela, Fingerle, Alexander A., Rummeny, Ernst J., Pfeiffer, Franz, Baum, Thomas, Noël, Peter B. · 2017 · Scientific Reports
Cited by 42

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

To assess whether phantomless calcium-hydroxyapatite (HA) specific bone mineral density (BMD) measurements with dual-layer spectral computed tomography are accurate in phantoms and vertebral specimens. Ex-vivo human vertebrae (n = 13) and a phantom containing different known HA concentrations were placed in a semi-anthropomorphic abdomen phantom with different extension rings simulating different degrees of obesity. Phantomless dual-layer spectral CT was performed at different tube current settings (500, 250, 125 and 50 mAs). HA-specific BMD was derived from spectral-based virtual monoenergetic images at 50 keV and 200 keV. Values were compared to the HA concentrations of the phantoms and conventional qCT measurements using a reference phantom, respectively. Above 125 mAs, errors for phantom measurements ranged between −1.3% to 4.8%, based on spectral information. In vertebral specimens, high correlations were found between BMD values assessed with spectral CT and conventional qCT (r ranging between 0.96 and 0.99; p < 0.001 for all) with different extension rings, and a high agreement was found in Bland Altman plots. Different degrees of obesity did not have a significant influence on measurements (P > 0.05 for all). These results suggest a high validity of HA-specific BMD measurements based on dual-layer spectral CT examinations in setups simulating different degrees of obesity without the need for a reference phantom, thus demonstrating their feasibility in clinical routine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-17855-4

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 42

Metadata

Authors
Mei, K., Schwaiger, B. J., Kopp, F. K., Ehn, S., Gersing, A. S., Kirschke, J. S., Muenzel, D., Fingerle, A. A., Rummeny, E. J., Pfeiffer, F., Baum, T., & Noël, P. B.
Venue
Scientific Reports
Published
2017-12-13
Volume
7
Issue
1
Pages
17519-17519
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2771633437
Cited by
42
References
6
FWCI
2.21
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography. https://app.cochat.ai/papers/10.1038/s41598-017-17855-4
The paper
Mei, K., Schwaiger, B. J., Kopp, F. K., Ehn, S., Gersing, A. S., Kirschke, J. S., Muenzel, D., Fingerle, A. A., Rummeny, E. J., Pfeiffer, F., Baum, T., & Noël, P. B. (2017). Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography. Scientific Reports. https://doi.org/10.1038/s41598-017-17855-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.