CoChat

Near-Field Scanning Microwave Microscopy in the Single Photon Regime

Open access

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

The microwave properties of nano-scale structures are important in a wide variety of applications in quantum technology. Here we describe a low-power cryogenic near-field scanning microwave microscope (NSMM) which maintains nano-scale dielectric contrast down to the single microwave photon regime, up to 10 9 times lower power than in typical NSMMs. We discuss the remaining challenges towards developing nano-scale NSMM for quantum coherent interaction with two-level systems as an enabling tool for the development of quantum technologies in the microwave regime.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-019-48780-3

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) Diagram of the set-up of the NSMM microscope. A superconducting fractal resonator, with average photon occupancy 〈n〉 ~ 1, is adhered to a quartz tuning fork. A movable CPW is used to inductively couple to the resonator for excitation and readout. (b) Illustration of the NSMM suspended by springs and kevlar wire inside a dilution refrigerator. Feed-throughs at the 800 mK plate are designed to reduce the amount of thermal photons from hotter stages reaching the NSMM.
Figure 1 (a) Diagram of the set-up of the NSMM microscope. A superconducting fractal resonator, with average photon occupancy 〈n〉 ~ 1, is adhered to a quartz tuning fork. A movable CPW is used to inductively couple to the resonator for excitation and readout. (b) Illustration of the NSMM suspended by springs and kevlar wire inside a dilution refrigerator. Feed-throughs at the 800 mK plate are designed to reduce the amount of thermal photons from hotter stages reaching the NSMM.CC BY · PubMed Central
Figure 2 (a) The intrinsic quality factor of the resonator probe as a function of average photon number 〈n〉, for three different temperatures. The data (•) is fitted (—) to Qi(〈n〉) (see text). (b) The frequency shift of the resonator probe as a function of tip-to-sample distance. Inset: The frequency shift at small distances with a linear approximation. The gradient of 0.84 kHz/nm from this data is what we use to convert from frequency noise to tip-to-sample displacement noise. (c) The intrinsic (left axis) and coupling (right axis) quality factors as a function of the number of steps made by the coupling piezo-stepper (coupling distance).
Figure 2 (a) The intrinsic quality factor of the resonator probe as a function of average photon number 〈n〉, for three different temperatures. The data (•) is fitted (—) to Qi(〈n〉) (see text). (b) The frequency shift of the resonator probe as a function of tip-to-sample distance. Inset: The frequency shift at small distances with a linear approximation. The gradient of 0.84 kHz/nm from this data is what we use to convert from frequency noise to tip-to-sample displacement noise. (c) The intrinsic (left axis) and coupling (right axis) quality factors as a function of the number of steps made by the coupling piezo-stepper (coupling distance).CC BY · PubMed Central
Figure 3 PSD of the microwave frequency shift Δfr, from the superconducting resonator. The peak at 1.4 Hz is the pulse tube. Red line: When the tip is in contact at low power (〈n〉 ~ 1). Purple line: When the tip is in contact at high power. Blue line: When the tip is retracted 5 nm from the surface at high power. The kink in the data from ~101 Hz is the roll-off of the PID bandwidth in the PDH loop.
Figure 3 PSD of the microwave frequency shift Δfr, from the superconducting resonator. The peak at 1.4 Hz is the pulse tube. Red line: When the tip is in contact at low power (〈n〉 ~ 1). Purple line: When the tip is in contact at high power. Blue line: When the tip is retracted 5 nm from the surface at high power. The kink in the data from ~101 Hz is the roll-off of the PID bandwidth in the PDH loop.CC BY · PubMed Central
Figure 4 Scans of an interdigitated capacitor with adjacent metallic pads taken at 30 mK. (a) AFM Topography scan. (b) Single photon regime microwave scan (〈n〉 ~ 1) showing the frequency shift of the microwave resonator. The images were acquired using a scan speed of 0.67 μm/s. (c) Microwave scan at high power (〈n〉 ~ 270). (d) The PDH error signal demodulated at the tuning fork frequency (30 kHz), proportional to dfr/dz (〈n〉 ~ 270). (e) The signal-to-noise ratio (SNR) obtained from scans as a function of the average photon number 〈n〉.
Figure 4 Scans of an interdigitated capacitor with adjacent metallic pads taken at 30 mK. (a) AFM Topography scan. (b) Single photon regime microwave scan (〈n〉 ~ 1) showing the frequency shift of the microwave resonator. The images were acquired using a scan speed of 0.67 μm/s. (c) Microwave scan at high power (〈n〉 ~ 270). (d) The PDH error signal demodulated at the tuning fork frequency (30 kHz), proportional to dfr/dz (〈n〉 ~ 270). (e) The signal-to-noise ratio (SNR) obtained from scans as a function of the average photon number 〈n〉.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Cited by

See all 43

Metadata

Authors
Geaney, S., Cox, D., Hönigl-Decrinis, T., Shaikhaidarov, R., Kubatkin, S. E., Lindström, T., Danilov, A. V., & de Graaf, S. E.
Affiliations
  • National Physical Laboratory (GB)
  • University of Surrey (GB)
  • Royal Holloway University of London (GB)
  • Chalmers University of Technology (SE)
Corresponding author
Geaney, S.
Venue
Scientific Reports
Published
2019-08-29
Volume
9
Issue
1
Pages
12539-12539
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2971342552
Cited by
37
References
45
Citations by year
2025: 5 · 2024: 3 · 2023: 6 · 2022: 6 · 2021: 6 · 2020: 11
FWCI
2.07
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • Chalmers Research (Chalmers University of Technology) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Vetenskapsrådet
  • Engineering and Physical Sciences Research Council (EP/P001521/1)
  • Royal Holloway, University of London
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
Keywords
near-field scanning microwave microscopy, single-photon detection, two-level system

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Near-Field Scanning Microwave Microscopy in the Single Photon Regime. https://app.cochat.ai/papers/10.1038/s41598-019-48780-3
The paper
Geaney, S., Cox, D., Hönigl-Decrinis, T., Shaikhaidarov, R., Kubatkin, S. E., Lindström, T., Danilov, A. V., & de Graaf, S. E. (2019). Near-Field Scanning Microwave Microscopy in the Single Photon Regime. Scientific Reports. https://doi.org/10.1038/s41598-019-48780-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.