Quantification for non-targeted LC/MS screening without standard substances
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Non-targeted and suspect analyses with liquid chromatography/electrospray/high-resolution mass spectrometry (LC/ESI/HRMS) are gaining importance as they enable identification of hundreds or even thousands of compounds in a single sample. Here, we present an approach to address the challenge to quantify compounds identified from LC/HRMS data without authentic standards. The approach uses random forest regression to predict the response of the compounds in ESI/HRMS with a mean error of 2.2 and 2.0 times for ESI positive and negative mode, respectively. We observe that the predicted responses can be transferred between different instruments via a regression approach. Furthermore, we applied the predicted responses to estimate the concentration of the compounds without the standard substances. The approach was validated by quantifying pesticides and mycotoxins in six different cereal samples. For applicability, the accuracy of the concentration prediction needs to be compatible with the effect (e.g. toxicology) predictions. We achieved the average quantification error of 5.4 times, which is well compatible with the accuracy of the toxicology predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regularization Paths for Generalized Linear Models via Coordinate Descent
Friedman, J., Hastie, T., & Tibshirani, R. (2010) · Journal of Statistical Software · doi:10.18637/jss.v033.i01 · Cited by 19,927
DrugBank 5.0: a major update to the DrugBank database for 2018
Wishart, D. S., Feunang, Y. D., Guo, A. C., Lo, E. J., Marcu, A., Grant, J. R., Sajed, T., Johnson, D., Li, C., Sayeeda, Z., et al. (2018) · Nucleic Acids Research · doi:10.1093/nar/gkx1037 · Cited by 8,404
HMDB 4.0: the human metabolome database for 2018
Wishart, D. S., Feunang, Y. D., Marcu, A., Guo, A. C., Liang, K., Vázquez-Fresno, R., Sajed, T., Johnson, D., Li, C., Karu, N., et al. (2018) · Nucleic Acids Research · doi:10.1093/nar/gkx1089 · Cited by 3,438
PaDEL‐descriptor: An open source software to calculate molecular descriptors and fingerprints
Yap, C. W. (2011) · Journal of Computational Chemistry · doi:10.1002/jcc.21707 · Cited by 2,962
Introduction to Modern Liquid Chromatography
Snyder, L. R., Kirkland, J. J., & Dolan, J. W. (2009) · Wiley eBooks · doi:10.1002/9780470508183 · Cited by 2,460
MetFrag relaunched: incorporating strategies beyond in silico fragmentation
Ruttkies, C., Schymanski, E. L., Wolf, S., Hollender, J., & Neumann, S. (2016) · Journal of Cheminformatics · doi:10.1186/s13321-016-0115-9 · Cited by 1,052
Neonicotinoids in bees: a review on concentrations, side-effects and risk assessment
Blacquière, T., Smagghe, G., van Gestel, C. A. M., & Mommaerts, V. (2012) · Ecotoxicology · doi:10.1007/s10646-012-0863-x · Cited by 1,039
Cajka, T., & Fiehn, O. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04491 · Cited by 830 · cited 3×
“To minimize the influence of possible differences in conditions when measuring M1 and anchor compound, two steps were taken: (1) each compound was measured on at least three different runs (on three different days) and the results were averaged, and (2) anchor compound was measured in the beginning and the end of each…”
MethodAn overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Schymanski, E. L., Singer, H. P., Slobodnik, J., Ipolyi, I. M., Oswald, P., Krauss, M., Schulze, T., Haglund, P., Letzel, T., Grosse, S., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8681-7 · Cited by 703 · cited 1×
“= ⋅ + RF slope IE intercept log log (5) pred pred”
BackgroundResidue analysis of 500 high priority pesticides: Better by GC–MS or LC–MS/MS?
Alder, L., Greulich, K., Kempe, G., & Vieth, B. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20091 · Cited by 623
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530 · cited 4×
“= + IE RIE M M IE log log ( / ) log (2) M 1 2 anchor 1”
MethodInfluentialDjoumbou-Feunang, Y., Fiamoncini, J., Gil-de-la-Fuente, A., Greiner, R., Manach, C., & Wishart, D. S. (2019) · Journal of Cheminformatics · doi:10.1186/s13321-018-0324-5 · Cited by 508
Allen, F., Pon, A., Wilson, M., Greiner, R., & Wishart, D. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku436 · Cited by 464
ChemDes: an integrated web-based platform for molecular descriptor and fingerprint computation
Dong, J., Cao, D.-S., Miao, H.-Y., Liu, S., Deng, B.-C., Yun, Y.-H., Wang, N.-N., Lu, A.-P., Zeng, W.-B., & Chen, A. F. (2015) · Journal of Cheminformatics · doi:10.1186/s13321-015-0109-z · Cited by 404
Relating Electrospray Ionization Response to Nonpolar Character of Small Peptides
Cech, N. B., & Enke, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac9914869 · Cited by 342
Self-citationLiquid chromatography–mass spectrometry in food safety
Malik, A. K., Blasco, C., & Picó, Y. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.03.015 · Cited by 318
Electrospray Ionization Efficiency Scale of Organic Compounds
Oss, M., Kruve, A., Herodes, K., & Leito, I. (2010) · Analytical Chemistry · doi:10.1021/ac902856t · Cited by 309
Self-citationFeature selection via regularized trees
Deng, H., & Runger, G. (2012) · The 2012 International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2012.6252640 · Cited by 180
Henriksen, T., Juhler, R. K., Svensmark, B., & Cech, N. B. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.11.021 · Cited by 166
Self-citationThink Negative: Finding the Best Electrospray Ionization/MS Mode for Your Analyte
Liigand, P., Kaupmees, K., Haav, K., Liigand, J., Leito, I., Girod, M., Antoine, R., & Kruve, A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00096 · Cited by 159
Self-citationSodium adduct formation efficiency in ESI source
Kruve, A., Kaupmees, K., Liigand, J., Oss, M., & Leito, I. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3218 · Cited by 153
Self-citationChalcraft, K. R., Lee, R., Mills, C., & Britz-McKibbin, P. (2009) · Analytical Chemistry · doi:10.1021/ac802272u · Cited by 139
Džuman, Z., Stranska-Zachariasova, M., Veprikova, Z., Godula, M., & Hajšlová, J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.01.021 · Cited by 135
Automatic recalibration and processing of tandem mass spectra using formula annotation
Stravs, M. A., Schymanski, E., Singer, H., & Hollender, J. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3131 · Cited by 125
Du, K.-L., & Swamy, M. N. S. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5571-3_16 · Cited by 110
Ehrmann, B. M., Henriksen, T., & Cech, N. B. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.01.003 · Cited by 102
Self-citationHuffman, B. A., Poltash, M. L., & Hughey, C. A. (2012) · Analytical Chemistry · doi:10.1021/ac302397b · Cited by 87
Effect of Mobile Phase on Electrospray Ionization Efficiency
Liigand, J., Kruve, A., Leito, I., Girod, M., & Antoine, R. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0969-x · Cited by 85
Self-citationHermans, J. H., Ongay, S., Markov, V. V., & Bischoff, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01899 · Cited by 59
Cited by
NORMAN guidance on suspect and non-target screening in environmental monitoring
Hollender, J., Schymanski, E. L., Ahrens, L., Alygizakis, N., Béen, F., Bijlsma, L., Brunner, A. M., Celma, A., Fildier, A., Fu, Q., et al. (2023) · Environmental Sciences Europe · doi:10.1186/s12302-023-00779-4 · Cited by 278
Self-citationPlastic Products Leach Chemicals That Induce In Vitro Toxicity under Realistic Use Conditions
Zimmermann, L., Bartosova, Z., Braun, K., Oehlmann, J., Völker, C., & Wagner, M. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c01103 · Cited by 268
Ruan, T., Li, P., Wang, H., Li, T., & Jiang, G. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00056 · Cited by 212
Manz, K. E., Feerick, A., Braun, J. M., Feng, Y.-L., Hall, A., Koelmel, J., Manzano, C., Newton, S. R., Pennell, K. D., Place, B. J., et al. (2023) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-023-00574-6 · Cited by 195
Hu, J., Lyu, Y., Chen, H., Cai, L., Li, J., Cao, X., & Sun, W. (2023) · Water Research · doi:10.1016/j.watres.2023.119735 · Cited by 121
Metadata
- Authors
- Liigand, J., Wang, T., Kellogg, J., Smedsgaard, J., Cech, N., & Kruve, A.
- Venue
- Scientific Reports
- Published
- 2020-04-02
- Volume
- 10
- Issue
- 1
- Pages
- 5808-5808
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3014785674
- Cited by
- 183
- References
- 30
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.