CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Cardiac CINE magnetic resonance imaging is the gold-standard for the assessment of cardiac function. Imaging accelerations have shown to enable 3D CINE with left ventricular (LV) coverage in a single breath-hold. However, 3D imaging remains limited to anisotropic resolution and long reconstruction times. Recently deep learning has shown promising results for computationally efficient reconstructions of highly accelerated 2D CINE imaging. In this work, we propose a novel 4D (3D + time) deep learning-based reconstruction network, termed 4D CINENet, for prospectively undersampled 3D Cartesian CINE imaging. CINENet is based on (3 + 1)D complex-valued spatio-temporal convolutions and multi-coil data processing. We trained and evaluated the proposed CINENet on in-house acquired 3D CINE data of 20 healthy subjects and 15 patients with suspected cardiovascular disease. The proposed CINENet network outperforms iterative reconstructions in visual image quality and contrast (+ 67% improvement). We found good agreement in LV function (bias ± 95% confidence) in terms of end-systolic volume (0 ± 3.3 ml), end-diastolic volume (− 0.4 ± 2.0 ml) and ejection fraction (0.1 ± 3.2%) compared to clinical gold-standard 2D CINE, enabling single breath-hold isotropic 3D CINE in less than 10 s scan and ~ 5 s reconstruction time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
A Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2017) · arXiv · doi:10.48550/arxiv.1711.11248 · Cited by 3,664
A Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00675 · Cited by 3,516
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Self-citationImage reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
A deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Self-citationAdvances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning
Ravishankar, S., & Bresler, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2090538 · Cited by 1,059
Deep ADMM-Net for compressive sensing MRI
Yang, Y., Sun, J. Z., Li, H., & Xu, Z. (2016) · neural information processing systems · Cited by 1,024
Design and validation of Segment - freely available software for cardiovascular image analysis
Heiberg, E., Sjögren, J., Ugander, M., Carlsson, M., Engblom, H., & Arheden, H. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-1 · Cited by 929
Accelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23639 · Cited by 606
Convolutional Recurrent Neural Networks for Dynamic MR Image Reconstruction
Qin, C., Schlemper, J., Caballero, J., Price, A. N., Hajnal, J. V., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2863670 · Cited by 603
Self-citationDeep Generative Adversarial Neural Networks for Compressive Sensing MRI
Mardani, M., Gong, E., Cheng, J. Y., Vasanawala, S. S., Zaharchuk, G., Xing, L., & Pauly, J. M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2858752 · Cited by 552
Eo, T., Jun, Y., Kim, T., Jang, J., Lee, H., & Hwang, D. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27201 · Cited by 455
Deep learning for undersampled MRI reconstruction
Hyun, C. M., Kim, H. P., Lee, S. M., Lee, S., & Seo, J. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aac71a · Cited by 428
${k}$ -Space Deep Learning for Accelerated MRI
Han, Y., Sunwoo, L., & Ye, J. C. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2927101 · Cited by 344
Deep Residual Learning for Accelerated MRI Using Magnitude and Phase Networks
Lee, D., Yoo, J., Tak, S., & Ye, J. C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2821699 · Cited by 340
Artificial Intelligence for MR Image Reconstruction: An Overview for Clinicians
Lin, D. J., Johnson, P. M., Knoll, F., & Lui, Y. W. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27078 · Cited by 291
Better than real: Complex-valued neural nets for MRI fingerprinting
Virtue, P., Yu, S. X., & Lustig, M. S. (2017) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2017.8297024 · Cited by 171
Feng, L., Coppo, S., Piccini, D., Yerly, J., Lim, R. P., Masci, P. G., Stuber, M., Sodickson, D. K., & Otazo, R. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26745 · Cited by 171
Self-citationCompressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass
Vincenti, G. M., Monney, P. A., Chaptinel, J., Rutz, T., Coppo, S., Zenge, M. O., Schmidt, M., Nadar, M. S., Piccini, D., Chèvre, P., et al. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.04.016 · Cited by 165
Complex-Valued Neural Networks With Nonparametric Activation Functions
Scardapane, S., Vaerenbergh, S. V., Hussain, A., & Uncini, A. (2018) · IEEE Transactions on Emerging Topics in Computational Intelligence · doi:10.1109/tetci.2018.2872600 · Cited by 139
Chen, F., Taviani, V., Malkiel, I., Cheng, J. Y., Tamir, J. I., Shaikh, J., Chang, S. T., Hardy, C. J., Pauly, J. M., & Vasanawala, S. S. (2018) · Radiology · doi:10.1148/radiol.2018180445 · Cited by 129
Hansen, M. S., Sørensen, T. S., Arai, A. E., & Kellman, P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23284 · Cited by 106
Complex-valued Neural Networks
Hirose, A. (2011) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.131.2 · Cited by 103
Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory
Usman, M., Ruijsink, B., Nazir, M. S., da Cruz, G. J. L., & Prieto, C. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.12.021 · Cited by 89
Self-citationComplex Fully Convolutional Neural Networks for MR Image Reconstruction
Dedmari, M. A., Conjeti, S., Estrada, S., Ehses, P., Stöcker, T., & Reuter, M. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-00129-2_4 · Cited by 60
Reconstruction techniques for cardiac cine MRI
Menchón-Lara, R.-M., Simmross‐Wattenberg, F., Casaseca‐de‐la‐Higuera, P., Martín‐Fernández, M., & Alberola‐López, C. (2019) · Insights into Imaging · doi:10.1186/s13244-019-0754-2 · Cited by 58
Super-resolution reconstruction of cardiac MRI using coupled dictionary learning
Bhatia, K. K., Price, A. N., Shi, W., Hajnal, J. V., & Rueckert, D. (2014) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6868028 · Cited by 58
Self-citationMalavé, M. O., Baron, C. A., Koundinyan, S. P., Sandino, C. M., Ong, F., Cheng, J. Y., & Nishimura, D. G. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28177 · Cited by 50
Highly Scalable Image Reconstruction using Deep Neural Networks with Bandpass FilteringPreprint
Cheng, J. Y., Chen, F., Alley, M. T., Pauly, J. M., & Vasanawala, S. S. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1805.03300 · Cited by 46 · cited 1×
“Cropping of the 4D volume into smaller chunks would hence (a) loose dynamic information if cropped along temporal dimension or (b) demand consideration of band-pass filtering in data consistency 48 implying a more complicated data fidelity block if cropped along spatial dimension.”
BackgroundHosseini, S. A. H., Zhang, C., Weingärtner, S., Moeller, S., Stuber, M., Uǧurbil, K., & Akçakaya, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0229418 · Cited by 45
Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling
Wetzl, J., Schmidt, M., Pontana, F., Longère, B., Lugauer, F., Maier, A., Hornegger, J., & Forman, C. (2017) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0624-1 · Cited by 44
Deep Learning Methods for Parallel Magnetic Resonance Image ReconstructionPreprint
Knöll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akçakaya, M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.01112 · Cited by 37
Self-citationKüstner, T., Bustin, A., Jaubert, O., Hajhosseiny, R., Masci, P. G., Neji, R., Botnar, R. M., & Prieto, C. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28267 · Cited by 37
Self-citationBarkauskas, K. J., Rajiah, P. S., Ashwath, R. C., Hamilton, J., Chen, Y., Ma, D., Wright, K. L., Gulani, V., Griswold, M. A., & Seiberlich, N. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0065-1 · Cited by 33
Makowski, M. R., Wiethoff, A. J., Jansen, C. H. P., Uribe, S. A., Parish, V., Schuster, A., Botnar, R. M., Bell, A., Kiesewetter, C., Razavi, R., et al. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-53 · Cited by 29
Self-citationChen, F., Cheng, J. Y., Taviani, V., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26871 · Cited by 26
Odille, F., Bustin, A., Liu, S., Chen, B., Vuissoz, P., Felblinger, J., & Bonnemains, L. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26923 · Cited by 26
Self-citationFerrazzi, G., Bassenge, J. P., Wink, C., Ruh, A., Markl, M., Moeller, S., Metzger, G. J., Ittermann, B., & Schmitter, S. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27460 · Cited by 18
Non‐Cartesian slice‐GRAPPA and slice‐SPIRiT reconstruction methods for multiband spiral cardiac MRI
Sun, C., Yang, Y., Cai, X., Salerno, M., Meyer, C. H., Weller, D. S., & Epstein, F. H. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28002 · Cited by 16
Complex Fully Convolutional Neural Networks for MR Image ReconstructionPreprint
Dedmari, M. A., Conjeti, S., Estrada, S., Ehses, P., Stöcker, T., & Reuter, M. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.03343 · Cited by 7 · cited 1×
“…multi-coil data consistency is given as a one-step proximal gradient which is defined in the forward pass as with the scaled undersampling mask We use Wirtinger calculus 55–57 during backpropagation to update the complex-valued weights of each layer with respect to the real-valued loss function.”
MethodAccelerating cardiac cine MRI beyond compressed sensing using DL-ESPIRiT.Preprint
Sandino, C. M., Lai, P., Vasanawala, S. S., et al. (2019) · arXiv (Cornell University) · Cited by 1
Cited by
Adaptive diffusion priors for accelerated MRI reconstruction
Güngör, A., Dar, S. U., Öztürk, Ş., Korkmaz, Y., Bedel, H. A., Elmas, G., Ozbey, M., & Çukur, T. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102872 · Cited by 246
“de-aliasing prior to suppress undersampling artifacts, so they have explicit knowledge of the imaging operator that reflects the choice of sampling patterns and coil sensitivities for acceleration (Polak et al., 2020; Feng et al., 2021; Küstner et al., 2020; Sriram et al., 2020).”
BackgroundMastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Metadata
- Authors
- Küstner, T., Fuin, N., Hammernik, K., Bustin, A., Qi, H., Hajhosseiny, R., Masci, P. G., Neji, R., Rueckert, D., Botnar, R. M., & Prieto, C.
- Venue
- Scientific Reports
- Published
- 2020-08-13
- Volume
- 10
- Issue
- 1
- Pages
- 13710-13710
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3048384642
- Cited by
- 233
- References
- 48
- FWCI
- 13.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.