The limit of tolerable micromotion for implant osseointegration: a systematic review
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Much research effort is being invested into the development of porous biomaterials that enhance implant osseointegration. Large micromotions at the bone-implant interface impair this osseointegration process, resulting in fibrous capsule formation and implant loosening. This systematic review compiled all the in vivo evidence available to establish if there is a universal limit of tolerable micromotion for implant osseointegration. The protocol was registered with the International Prospective Register for Systematic Reviews (ID: CRD42020196686). Pubmed, Scopus and Web of Knowledge databases were searched for studies containing terms relating to micromotion and osseointegration. The mean value of micromotion for implants that osseointegrated was 32% of the mean value for those that did not (112 ± 176 µm versus 349 ± 231 µm, p < 0.001). However, there was a large overlap in the data ranges with no universal limit apparent. Rather, many factors were found to combine to affect the overall outcome including loading time, the type of implant and the material being used. The tables provided in this review summarise these factors and will aid investigators in identifying the most relevant micromotion values for their biomaterial and implant development research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009) · doi:10.1002/9780470743386 · Cited by 14,225
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2_v1 · Cited by 8,090
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2 · Cited by 5,177
Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants
PILLIAR, R. M., LEE, J. M., & MANIATOPOULOS, C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198607000-00023 · Cited by 1,182
Perren, S. M. (2002) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.84b8.0841093 · Cited by 916
Claes, L. E., & Heigele, C. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00153-5 · Cited by 802
Mechanobiology of Skeletal Regeneration
Carter, D. R., Beaupr??, G. S., Giori, N. J., & Helms, J. A. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00006 · Cited by 758
Søballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100216 · Cited by 506
Osseointegration and current interpretations of the bone-implant interface
Shah, F. A., Thomsen, P., & Palmquist, A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.018 · Cited by 381
Recovery periods restore mechanosensitivity to dynamically loaded bone
Robling, A. G., Burr, D. B., & Turner, C. H. (2001) · Journal of Experimental Biology · doi:10.1242/jeb.204.19.3389 · Cited by 376
Implant micromotion is related to peak insertion torque and bone density
Trisi, P., Perfetti, G., Baldoni, E., Berardi, D., Colagiovanni, M., & Scogna, G. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01679.x · Cited by 285 · cited 3×
“analysis (FEA) or computational studies; (4) cemented implants; (5) cadaveric bone in vitro experiments where prostheses were inserted post-mortem; and (6) synthetic bone in vitro experiments.”
MethodUtilization rates of hip arthroplasty in OECD countries
Pabinger, C., & Geissler, A. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2014.04.009 · Cited by 265
Apostu, D., Lucaciu, O., Berce, C., Lucaciu, D., & Cosma, D. (2018) · Journal of International Medical Research · doi:10.1177/0300060517732697 · Cited by 236
Utilization rates of knee-arthroplasty in OECD countries
Pabinger, C., Lothaller, H., & Geissler, A. (2015) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2015.05.008 · Cited by 212 · cited 4×
“Studies which fulfilled the following criteria were included: (1) in vivo animal research or post-mortem human data where the implant was inserted pre-mortem.”
BackgroundMethodInfluentialNano hydroxyapatite structures influence early bone formation
Meirelles, L., Arvidsson, A., Andersson, M., Kjellin, P., Albrektsson, T., & Wennerberg, A. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31744 · Cited by 212
Bone remodelling in vitro: Where are we headed?
Kohli, N., Ho, S., Brown, S. J., Sawadkar, P., Sharma, V., Snow, M., & García‐Gareta, E. (2018) · Bone · doi:10.1016/j.bone.2018.01.015 · Cited by 173
Self-citationThe costs of removing the unsanctioned import of marine plastic litter to small island states
Burt, A., Raguain, J., Sanchez, C. L., Brice, J., Fleischer‐Dogley, F., Goldberg, R. L., Talma, S., Syposz, M., Mahony, J., Letori, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-71444-6 · Cited by 167
Micromotion-induced strain fields influence early stages of repair at bone–implant interfaces
Wazen, R. M., Currey, J. A., Guo, H., Brunski, J., Helms, J. A., & Nanci, A. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.014 · Cited by 165
Effect of mechanical stimuli on skeletal regeneration around implants
Leucht, P., Kim, J.-B., Wazen, R., Currey, J. A., Nanci, A., Brunski, J. B., & Helms, J. A. (2007) · Bone · doi:10.1016/j.bone.2006.10.027 · Cited by 163
Duyck, J. A. J., Vandamme, K., Geris, L., Oosterwyck, H. V., Cooman, M. D., VanderSloten, J., Puers, R., & Naert, I. E. (2005) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2005.04.003 · Cited by 150
Intermittent micromotion inhibits bone ingrowth
Aspenberg, P., Goodman, S. B., Toksvig‐Larsen, S., Ryd, L., & Albrektsson, T. O. (1992) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679209154809 · Cited by 147
Haïat, G., Wang, H., & Brunski, J. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104854 · Cited by 140 · cited 1×
“analysis (FEA) or computational studies; (4) cemented implants; (5) cadaveric bone in vitro experiments where prostheses were inserted post-mortem; and (6) synthetic bone in vitro experiments.”
Saxon, L. K., Robling, A. G., Alam, I., & Turner, C. H. (2005) · Bone · doi:10.1016/j.bone.2004.12.001 · Cited by 109
Vandamme, K., Naert, I. E., Geris, L., Sloten, J. V., Puers, R., & Duyck, J. A. J. (2007) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2007.00416.x · Cited by 107
Overgaard, S., Søballé, K., Josephsen, K., Hansen, E. S., & Bünger, C. E. (1996) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100140607 · Cited by 86
Osseointegration under Immediate Loading: Biomechanical Stress–Strain and Bone Formation–Resorption
Kawahara, H., Kawahara, D., Hayakawa, M., Tamai, Y., Kuremoto, T., & Matsuda, S. (2003) · Implant Dentistry · doi:10.1097/01.id.0000034394.75768.e3 · Cited by 83 · cited 1×
“…Every gait cycle 500 Jasty 1997 20 Dogs 5 4 Titanium None Femur 6 Unloaded N/A Unloaded 9.3 ± 2.3 6 20 µm micro-motion 8 h/day 20 9.0 ± 3.1 6 40 µm micro-motion 8 h/day 40 11.8 ± 3.9 6 150 µm micro-motion 8 h/day 150 10.4 ± 3.0 Kawahara 2003 Beagles Titanium None Mandi-ble 6 8 N 10 s 30 580,…”
InfluentialThe interplay between bone healing and remodeling around dental implants
Irandoust, S., & Müftü, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-60735-7 · Cited by 81 · cited 4×
“Articles were excluded if: (1) micromotion was measured indirectly and/or reported as implant stability quotient (ISQ) or resonance frequency analysis (RFA); (2) Study duration less than 3 weeks; (3) Finite element 0 5 10 15 20 0 20 40 60 80”
BackgroundMethodInfluentialEffect of Implant Surface Roughness and Loading on Peri‐Implant Bone Formation
Vandamme, K., Naert, I. E., Sloten, J. V., Puers, R., & Duyck, J. A. J. (2007) · Journal of Periodontology · doi:10.1902/jop.2008.060413 · Cited by 77
In silicobiology of bone modelling and remodelling: regeneration
Geris, L., Sloten, J. V., & Oosterwyck, H. V. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0293 · Cited by 73
Goodman, S. B., Wang, J., Doshi, A., & Aspenberg, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271109 · Cited by 58
Breding, K., Jimbo, R., Hayashi, M. K., Xue, Y., Mustafa, K., & Andersson, M. (2014) · International Journal of Dentistry · doi:10.1155/2014/171305 · Cited by 38
Piuzzi, N. S. (2020) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.19.01155 · Cited by 38
Ovesy, M., Voumard, B., & Zysset, P. K. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1038-3 · Cited by 36
Micromotion and Migration of Cementless Tibial Trays Under Functional Loading Conditions
Han, S., Patel, R. V., Ismaily, S. K., Jones, H. L., Gold, J. E., & Noble, P. C. (2020) · The Journal of Arthroplasty · doi:10.1016/j.arth.2020.07.017 · Cited by 26 · cited 1×
“analysis (FEA) or computational studies; (4) cemented implants; (5) cadaveric bone in vitro experiments where prostheses were inserted post-mortem; and (6) synthetic bone in vitro experiments.”
Goodman, S. B., Aspenberg, P., Song, Y., Regula, D. P., & Lidgren, L. (1995) · Journal of Applied Biomaterials · doi:10.1002/jab.770060303 · Cited by 22
Chen, J., Zhang, X., Yangpeng, S., Deng, F., & Zhang, Z. (2020) · Journal of Biomaterials Applications · doi:10.1177/0885328219899523 · Cited by 21
Chanda, S., Mukherjee, K., Gupta, S., & Pratihar, D. K. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919890998 · Cited by 18
Goodman, S. B., Song, Y., Doshi, A., & Aspenberg, P. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90112-0 · Cited by 15
O’Rourke, D., & Taylor, M. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24636 · Cited by 11
A finite element analysis of tibial tritanium cones without stems in varying bone defects
Xie, S., Conlisk, N., Hamilton, D. F., Scott, C. E. H., Burnett, R., & Pankaj, P. (2020) · The Knee · doi:10.1016/j.knee.2020.02.019 · Cited by 11
Sheep Hip Arthroplasty Model of Failed Implant Osseointegration
Jakobsen, T., Kold, S., Baas, J., Søballé, K., & Rahbek, O. (2015) · The Open Orthopaedics Journal · doi:10.2174/1874325001509010525 · Cited by 6
Bueno, R. D. B. E. L., Dias, A. P. S., Ponce, K. J., Brunski, J., & Nanci, A. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34449 · Cited by 5
Parithimarkalaignan, S., & Padmanabhan, T. V. (2013) · The Journal of Indian Prosthodontic Society · doi:10.1007/s13191-013-0252-z
Cited by
Advances in guided bone regeneration membranes: a comprehensive review of materials and techniques
Ali, M., Mohd Noor, S. N. F., Mohamad, H., Ullah, F., Javed, F., & Abdul Hamid, Z. A. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad1e75 · Cited by 19
Metadata
- Authors
- Kohli, N., Stoddart, J. C., & van Arkel, R. J.
- Venue
- Scientific Reports
- Published
- 2021-05-24
- Volume
- 11
- Issue
- 1
- Pages
- 10797-10797
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3164319870
- Cited by
- 165
- References
- 44
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.