Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict Study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Early detection of diseases such as COVID-19 could be a critical tool in reducing disease transmission by helping individuals recognize when they should self-isolate, seek testing, and obtain early medical intervention. Consumer wearable devices that continuously measure physiological metrics hold promise as tools for early illness detection. We gathered daily questionnaire data and physiological data using a consumer wearable (Oura Ring) from 63,153 participants, of whom 704 self-reported possible COVID-19 disease. We selected 73 of these 704 participants with reliable confirmation of COVID-19 by PCR testing and high-quality physiological data for algorithm training to identify onset of COVID-19 using machine learning classification. The algorithm identified COVID-19 an average of 2.75 days before participants sought diagnostic testing with a sensitivity of 82% and specificity of 63%. The receiving operating characteristic (ROC) area under the curve (AUC) was 0.819 (95% CI [0.809, 0.830]). Including continuous temperature yielded an AUC 4.9% higher than without this feature. For further validation, we obtained SARS CoV-2 antibody in a subset of participants and identified 10 additional participants who self-reported COVID-19 disease with antibody confirmation. The algorithm had an overall ROC AUC of 0.819 (95% CI [0.809, 0.830]), with a sensitivity of 90% and specificity of 80% in these additional participants. Finally, we observed substantial variation in accuracy based on age and biological sex. Findings highlight the importance of including temperature assessment, using continuous physiological features for alignment, and including diverse populations in algorithm development to optimize accuracy in COVID-19 detection from wearables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissecting racial bias in an algorithm used to manage the health of populations
Obermeyer, Z., Powers, B., Vogeli, C., & Mullainathan, S. (2019) · Science · doi:10.1126/science.aax2342 · Cited by 7,137
Coordination of circadian timing in mammals
Reppert, S. M., & Weaver, D. R. (2002) · Nature · doi:10.1038/nature00965 · Cited by 4,379
Pre-symptomatic detection of COVID-19 from smartwatch data
Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00640-6 · Cited by 463
Wearable sensor data and self-reported symptoms for COVID-19 detection
Quer, G., Radin, J. M., Gadaleta, M., Baca-Motes, K., Ariniello, L., Ramos, E., Kheterpal, V., Topol, E. J., & Steinhubl, S. R. (2021) · Nature Medicine · doi:10.1038/s41591-020-1123-x · Cited by 447
Radin, J. M., Wineinger, N. E., Topol, E. J., & Steinhubl, S. R. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30222-5 · Cited by 300
Ahmad, S., Tejuja, A., Newman, K. D., Zarychanski, R., & Seely, A. J. (2009) · Critical Care · doi:10.1186/cc8132 · Cited by 151
Feasibility of continuous fever monitoring using wearable devices
Smarr, B. L., Aschbacher, K., Fisher, S. M., Chowdhary, A., Dilchert, S., Puldon, K., Rao, A., Hecht, F. M., & Mason, A. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-78355-6 · Cited by 133
Self-citation
Cited by
Kim, E. H., Jenness, J. L., Miller, A. B., Halabi, R., de Zambotti, M., Bagot, K. S., Baker, F. C., & Pratap, A. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.5681 · Cited by 53
Elevated body temperature is associated with depressive symptoms: results from the TemPredict Study
Mason, A. E., Kasl, P., Soltani, S., Green, A., Hartogensis, W., Dilchert, S., Chowdhary, A., Pandya, L. S., Siwik, C. J., Foster, S. L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-51567-w · Cited by 31
“The TemPredict Study 26,27 was a prospective, worldwide, cohort study that continuously collected physiological metrics (e.g., body temperature) using an off-the-shelf wearable device (Oura Ring) with the primary aim of developing an algorithm to identify the onset of COVID-19.”
Self-citationFive million nights: temporal dynamics in human sleep phenotypes
Viswanath, V. K., Hartogenesis, W., Dilchert, S., Pandya, L., Hecht, F. M., Mason, A. E., Wang, E. J., & Smarr, B. L. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01125-5 · Cited by 20
Self-citationUtilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach
Kasl, P., Keeler Bruce, L., Hartogensis, W., Dasgupta, S., Pandya, L. S., Dilchert, S., Hecht, F. M., Gupta, A., Altintas, I., Mason, A. E., et al. (2024) · Sensors · doi:10.3390/s24061818 · Cited by 13
“We previously reported on data collected for these analyses by Mason et al. [6].”
BackgroundMethodSelf-citationSoltani, S., Viswanath, V. K., Kasl, P., Hartogensis, W., Dilchert, S., Hecht, F. M., Mason, A. E., & Smarr, B. L. (2025) · Journal of Medical Internet Research · doi:10.2196/60284 · Cited by 3
Self-citation
Metadata
- Authors
- Mason, A. E., Hecht, F. M., Davis, S. K., Natale, J. L., Hartogensis, W., Damaso, N., Claypool, K. T., Dilchert, S., Dasgupta, S., Purawat, S., Viswanath, V. K., Klein, A., Chowdhary, A., Fisher, S. M., Anglo, C., Puldon, K. Y., Veasna, D., Prather, J. G., Pandya, L. S., Fox, L. M., Busch, M., Giordano, C., Mercado, B. K., Song, J., Jaimes, R., Baum, B. S., Telfer, B. A., Philipson, C. W., Collins, P. P., Rao, A. A., Wang, E. J., Bandi, R. H., Choe, B. J., Epel, E. S., Epstein, S. K., Krasnoff, J. B., Lee, M. B., Lee, S.-W., Lopez, G. M., Mehta, A., Melville, L. D., Moon, T. S., Mujica-Parodi, L. R., Noel, K. M., Orosco, M. A., Rideout, J. M., Robishaw, J. D., Rodriguez, R. M., Shah, K. H., Siegal, J. H., Gupta, A., Altintas, I., & Smarr, B. L.
- Venue
- Scientific Reports
- Published
- 2022-03-02
- Volume
- 12
- Issue
- 1
- Pages
- 3463-3463
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W4214931945
- Cited by
- 73
- References
- 7
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict Study. https://app.cochat.ai/papers/10.1038/s41598-022-07314-0
- The paper
- Mason, A. E., Hecht, F. M., Davis, S. K., Natale, J. L., Hartogensis, W., Damaso, N., Claypool, K. T., Dilchert, S., Dasgupta, S., Purawat, S., Viswanath, V. K., Klein, A., Chowdhary, A., Fisher, S. M., Anglo, C., Puldon, K. Y., Veasna, D., Prather, J. G., Pandya, L. S., . . . Smarr, B. L. (2022). Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict Study. Scientific Reports. https://doi.org/10.1038/s41598-022-07314-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.