CoChat

Safety of transcutaneous auricular vagus nerve stimulation (taVNS): a systematic review and meta-analysis

Open access
Kim, Angela Yun, Marduy, Anna, de Melo, Paulo S., Gianlorenco, Anna Carolyna, Kim, Chi Kyung, Choi, Hyuk, Song, Jae-Jun, Fregni, Felipe · 2022 · Scientific Reports
Cited by 195

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Transcutaneous auricular vagus nerve stimulation (taVNS) has been investigated as a novel neuromodulation tool. Although taVNS is generally considered safe with only mild and transient adverse effects (AEs), those specifically caused by taVNS have not yet been investigated. This systematic review and meta-analysis on taVNS aimed to (1) systematically analyze study characteristics and AE assessment, (2) characterize and analyze possible AEs and their incidence, (3) search for predictable risk factors, (4) analyze the severity of AE, and (5) suggest an evidence-based taVNS adverse events questionnaire for safety monitoring. The articles searched were published through April 7, 2022, in Medline, Embase, Web of Science, Cochrane, and Lilacs databases. In general, we evaluated 177 studies that assessed 6322 subjects. From these, 55.37% of studies did not mention the presence or absence of any AEs; only 24.86% of the studies described that at least one adverse event occurred. In the 35 studies reporting the number of subjects with at least one adverse event, a meta-analytic approach to calculate the risk differences of developing an adverse event between active taVNS and controls was used. The meta-analytic overall adverse events incidence rate was calculated for the total number of adverse events reported on a 100,000 person-minutes-days scale. There were no differences in risk of developing an adverse event between active taVNS and controls. The incidence of AE, in general, was 12.84/100,000 person-minutes-days of stimulation, and the most frequently reported were ear pain, headache, and tingling. Almost half of the studies did not report the presence or absence of any AEs. We attribute this to the absence of AE in those studies. There was no causal relationship between taVNS and severe adverse events. This is the first systematic review and meta-analysis of transcutaneous auricular stimulation safety. Overall, taVNS is a safe and feasible option for clinical intervention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-022-25864-1

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Metadata

Authors
Kim, A. Y., Marduy, A., de Melo, P. S., Gianlorenco, A. C., Kim, C. K., Choi, H., Song, J.-J., & Fregni, F.
Venue
Scientific Reports
Published
2022-12-21
Volume
12
Issue
1
Pages
22055-22055
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4312129236
Cited by
195
References
16
FWCI
5.20
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety of transcutaneous auricular vagus nerve stimulation (taVNS): a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1038/s41598-022-25864-1
The paper
Kim, A. Y., Marduy, A., de Melo, P. S., Gianlorenco, A. C., Kim, C. K., Choi, H., Song, J.-J., & Fregni, F. (2022). Safety of transcutaneous auricular vagus nerve stimulation (taVNS): a systematic review and meta-analysis. Scientific Reports. https://doi.org/10.1038/s41598-022-25864-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.