Safety of transcutaneous auricular vagus nerve stimulation (taVNS): a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Transcutaneous auricular vagus nerve stimulation (taVNS) has been investigated as a novel neuromodulation tool. Although taVNS is generally considered safe with only mild and transient adverse effects (AEs), those specifically caused by taVNS have not yet been investigated. This systematic review and meta-analysis on taVNS aimed to (1) systematically analyze study characteristics and AE assessment, (2) characterize and analyze possible AEs and their incidence, (3) search for predictable risk factors, (4) analyze the severity of AE, and (5) suggest an evidence-based taVNS adverse events questionnaire for safety monitoring. The articles searched were published through April 7, 2022, in Medline, Embase, Web of Science, Cochrane, and Lilacs databases. In general, we evaluated 177 studies that assessed 6322 subjects. From these, 55.37% of studies did not mention the presence or absence of any AEs; only 24.86% of the studies described that at least one adverse event occurred. In the 35 studies reporting the number of subjects with at least one adverse event, a meta-analytic approach to calculate the risk differences of developing an adverse event between active taVNS and controls was used. The meta-analytic overall adverse events incidence rate was calculated for the total number of adverse events reported on a 100,000 person-minutes-days scale. There were no differences in risk of developing an adverse event between active taVNS and controls. The incidence of AE, in general, was 12.84/100,000 person-minutes-days of stimulation, and the most frequently reported were ear pain, headache, and tingling. Almost half of the studies did not report the presence or absence of any AEs. We attribute this to the absence of AE in those studies. There was no causal relationship between taVNS and severe adverse events. This is the first systematic review and meta-analysis of transcutaneous auricular stimulation safety. Overall, taVNS is a safe and feasible option for clinical intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 34,787
Cochrane Handbook for Systematic Reviews of Interventions
(2019) · doi:10.1002/9781119536604 · Cited by 14,828
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2_v1 · Cited by 8,090
Cumpston, M., Li, T., Page, M. J., Chandler, J., Welch, V. A., Higgins, J. P., & Thomas, J. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.ed000142 · Cited by 7,218
How to perform a meta-analysis with R: a practical tutorial
Balduzzi, S., Rücker, G., & Schwarzer, G. (2019) · Evidence Based Mental Health · doi:10.1136/ebmental-2019-300117 · Cited by 5,827
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J., Bossuyt, P., Boutron, I., Hoffmann, T., mulrow, C., Shamseer, L., Tetzlaff, J., Akl, E., Brennan, S. E., et al. (2020) · doi:10.31222/osf.io/v7gm2 · Cited by 5,177
Purposeful selection of variables in logistic regression
Bursac, Z., Gauss, C. H., Williams, D. K., & Hosmer, D. W. (2008) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-3-17 · Cited by 4,035 · cited 1×
“A "purposeful selection" method was used to create the multivariate model; covariates that were not statistically or clinically significant as well as confounders were removed from the model 22 .”
The vagus nerve at the interface of the microbiota-gut-brain axis
Bonaz, B., Bazin, T., & Pellissier, S. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00049 · Cited by 1,397
A review of vagus nerve stimulation as a therapeutic intervention
Johnson, R. L., & Wilson, C. G. (2018) · Journal of Inflammation Research · doi:10.2147/jir.s163248 · Cited by 562
Nemeroff, C. B., Mayberg, H. S., Krahl, S. E., McNamara, J., Frazer, A., Henry, T. R., George, M. S., Charney, D. S., & Brannan, S. K. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301082 · Cited by 496 · cited 1×
“It is generally believed that taVNS must not be administered to the right ear, since efferent vagal fibers on the right side regulate heart rate 41,42 .”
Chronic vagus nerve stimulation in Crohn's disease: a 6‐month follow‐up pilot study
Bonaz, B., Sinniger, V., Hoffmann, D., Clarençon, D., Mathieu, N., Dantzer, C., Vercueil, L., Picq, C., Trocmé, C., Faure, P., et al. (2016) · Neurogastroenterology & Motility · doi:10.1111/nmo.12792 · Cited by 492
Ben‐Menachem, E., Revesz, D., Simon, B. J., & Silberstein, S. (2015) · European Journal of Neurology · doi:10.1111/ene.12629 · Cited by 344
Hein, E., Nowak, M., Kiess, O., Biermann, T., Bayerlein, K., Kornhuber, J., & Kraus, T. (2013) · Journal of Neural Transmission · doi:10.1007/s00702-012-0908-6 · Cited by 282 · cited 1×
“The NET-1000 and NET-2000 (Auri-Stim Medical, CO, USA) used four 3 mm electrodes placed crosswise to stimulate the bilateral outer ear canals 28 , while 35 studies (43.8”
InfluentialGolder, S., Loke, Y. K., Wright, K., & Norman, G. (2016) · PLOS Medicine · doi:10.1371/journal.pmed.1002127 · Cited by 277
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258
Analysis and reporting of adverse events in randomised controlled trials: a review
Phillips, R., Hazell, L., Sauzet, O., & Cornelius, V. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-024537 · Cited by 228
The effect of transcutaneous vagus nerve stimulation on cortical excitability
Capone, F., Assenza, G., Di Pino, G., Musumeci, G., Ranieri, F., Florio, L., Barbato, C., & Di Lazzaro, V. (2015) · Journal of Neural Transmission · doi:10.1007/s00702-014-1299-7 · Cited by 147
Hasan, A., Wolff-Menzler, C., Pfeiffer, S., Falkai, P., Weidinger, E., Jobst, A., Hoell, I., Malchow, B., Yeganeh-Doost, P., Strube, W., et al. (2015) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-015-0618-9 · Cited by 80 · cited 4×
“One study used the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use: Guidance for Good Clinical Practice to define adverse event severity, while two studies from the same author defined an adverse event as severe if the patient was hospitalized 31,32…”
Influential
Metadata
- Authors
- Kim, A. Y., Marduy, A., de Melo, P. S., Gianlorenco, A. C., Kim, C. K., Choi, H., Song, J.-J., & Fregni, F.
- Venue
- Scientific Reports
- Published
- 2022-12-21
- Volume
- 12
- Issue
- 1
- Pages
- 22055-22055
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W4312129236
- Cited by
- 195
- References
- 19
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.