EEG is better left alone
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Automated preprocessing methods are critically needed to process the large publicly-available EEG databases, but the optimal approach remains unknown because we lack data quality metrics to compare them. Here, we designed a simple yet robust EEG data quality metric assessing the percentage of significant channels between two experimental conditions within a 100 ms post-stimulus time range. Because of volume conduction in EEG, given no noise, most brain-evoked related potentials (ERP) should be visible on every single channel. Using three publicly available collections of EEG data, we showed that, with the exceptions of high-pass filtering and bad channel interpolation, automated data corrections had no effect on or significantly decreased the percentage of significant channels. Referencing and advanced baseline removal methods were significantly detrimental to performance. Rejecting bad data segments or trials could not compensate for the loss in statistical power. Automated Independent Component Analysis rejection of eyes and muscles failed to increase performance reliably. We compared optimized pipelines for preprocessing EEG data maximizing ERP significance using the leading open-source EEG software: EEGLAB, FieldTrip, MNE, and Brainstorm. Only one pipeline performed significantly better than high-pass filtering the data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 1×
“(2) For HAPPE, we used a 150-microvolt threshold.”
MethodThe PREP pipeline: standardized preprocessing for large-scale EEG analysis
Bigdely-Shamlo, N., Mullen, T., Kothe, C., Su, K.-M., & Robbins, K. A. (2015) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2015.00016 · Cited by 1,351
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Chronux: A platform for analyzing neural signals
Bokil, H., Andrews, P., Kulkarni, J. E., Mehta, S., & Mitra, P. P. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.06.020 · Cited by 865
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Real-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Autoreject: Automated artifact rejection for MEG and EEG data
Jas, M., Engemann, D. A., Bekhti, Y., Raimondo, F., & Gramfort, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.030 · Cited by 598
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
A Limit to the Speed of Processing in Ultra-Rapid Visual Categorization of Novel Natural Scenes
Fabre-Thorpe, M., Delorme, A., Marlot, C., & Thorpe, S. (2001) · Journal of Cognitive Neuroscience · doi:10.1162/089892901564234 · Cited by 339
Self-citationThe quest for the EEG reference revisited: A glance from brain asymmetry research
HAGEMANN, D., NAUMANN, E., & THAYER, J. F. (2001) · Psychophysiology · doi:10.1017/s0048577201001081 · Cited by 244
A multi-subject, multi-modal human neuroimaging dataset
Wakeman, D. G., & Henson, R. N. (2015) · Scientific Data · doi:10.1038/sdata.2015.1 · Cited by 190
Interaction of top-down and bottom-up processing in the fast visual analysis of natural scenes
Delorme, A., Rousselet, G. A., Macé, M. J.-M., & Fabre-Thorpe, M. (2004) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2003.11.010 · Cited by 167
Self-citationThe ICLabel dataset of electroencephalographic (EEG) independent component (IC) features
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · Data in Brief · doi:10.1016/j.dib.2019.104101 · Cited by 154
Klug, M., & Kloosterman, N. A. (2022) · Human Brain Mapping · doi:10.1002/hbm.25832 · Cited by 148
Understanding the Influences of EEG Reference: A Large-Scale Brain Network Perspective
Lei, X., & Liao, K. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00205 · Cited by 120
Clayson, P. E., Baldwin, S. A., Rocha, H. A., & Larson, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118712 · Cited by 106
Candia‐Rivera, D., Catrambone, V., & Valenza, G. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109269 · Cited by 85
Tanner, D., Norton, J. J. S., Morgan‐Short, K., & Luck, S. J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.01.002 · Cited by 70
Fló, A., Gennari, G., Benjamin, L., & Dehaene‐Lambertz, G. (2022) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2022.101077 · Cited by 64
A neuroscience gateway: software and implementation
Sivagnanam, S., Astakhov, V., Yoshimoto, K., Carnevale, T., Martone, M., Majumdar, A., & Bandrowski, A. (2013) · Proceedings of the Conference on Extreme Science and Engineering Discovery Environment: Gateway to Discovery · doi:10.1145/2484762.2484816 · Cited by 63
Perez‐Valero, E., Morillas, C. A., López-Gordo, M. A., Carrera-Muñoz, I., López-Alcalde, S., & Vílchez-Carrillo, R. M. (2022) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.924547 · Cited by 29
Zheng, G., Qi, X., Li, Y., Zhang, W., & Yu, Y. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00158 · Cited by 24
Automated Data Cleaning for the Muse EEG
Arnaud Delorme, A., & Martin, J. A. (2021) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm52615.2021.9669415 · Cited by 18
Shirk, S. D., McLaren, D. G., Bloomfield, J., Powers, A. E., Duffy, A., Mitchell, M. B., Ezzati, A., Ally, B. A., & Atri, A. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00322 · Cited by 13
Tools for Importing and Evaluating BIDS-EEG Formatted Data
Arnaud Delorme, A., Truong, D., Martínez-Cancino, R., Pernet, C. R., Sivagnanam, S., Yoshimoto, K. K., Poldrack, R. A., Majumdar, A., & Makeig, S. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441399 · Cited by 13
Bring a map when exploring the ERP data processing multiverse: A commentary on Clayson et al. 2021
Feuerriegel, D., & Bode, S. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119443 · Cited by 12
Metadata
- Authors
- Delorme, A.
- Venue
- Scientific Reports
- Published
- 2023-02-09
- Volume
- 13
- Issue
- 1
- Pages
- 2372-2372
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W4319826315
- Cited by
- 260
- References
- 30
- FWCI
- 36.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.