Electronic neural interfaces
The DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The former is less invasiveness and easier to implant. But the latter one have a better stimulation effect.[547]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [547]
In the citing paper
“Current-controlled stimulation can specify the injected charge, improving safety and efficacy, though at the cost of lower efficiency.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [8]
In the citing paper
“To address lower stimulation efficiency, switched-capacitor stimulating topologies have been developed to maintain high efficiency with adequate control over the charge; however, the circuit implementation requires large capacitors, which may exceed the available area of an implantable device [8].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [8]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Single-channel currents recorded from membrane of denervated frog muscle fibres
NEHER, E., & SAKMANN, B. (1976) · Nature · doi:10.1038/260799a0 · Cited by 2,570
Currents carried by sodium and potassium ions through the membrane of the giant axon of Loligo
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004717 · Cited by 2,491
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Transcranial Magnetic Stimulation: A Primer
Hallett, M. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.026 · Cited by 1,891
Research works printed but not linked: 1
- Rozgić, D. et al. A 0.338cm3, artifact-free, 64-contact neuromodulation platform for simultaneous stimulation and sensing. IEEE Trans. Biomed. Circ. Syst. 13, 38–55 (2018).
Cited by
Items 101–200 of 237
Lee, Y., Park, S. J., Kwon, J., Song, K., & Jung, S. (2025) · Science Advances · doi:10.1126/sciadv.ady0279 · Cited by 14
Biohybrid catalysis in biomedicine
Li, X., Zhang, Y., He, A., Li, Q., Wang, S., Shan, J., Li, S., Yang, D., Wu, G., Xiu, W., et al. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.217003 · Cited by 14
Danesh, A. R., Pu, H., Safiallah, M., Do, A. H., Nenadić, Z., & Heydari, P. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3391190 · Cited by 15
“The amplitude of ECoG signals is approximately in the range of 10-to 500-μ V [10].”
Functional‐Nanochannel‐Based Artificial Postsynaptic Membrane for Neural Signal Transduction
Wang, S., Zhang, W., Wu, M., Wu, Y., Xu, G., Liu, W., Mei, T., Lü, C., & Xiao, K. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202410597 · Cited by 13
Sun, L., Du, Y., Zhang, Z., Qin, S., Wang, Z., Li, Y., Qu, S., Xu, Z., Guo, Y., & Xu, W. (2024) · SmartMat · doi:10.1002/smm2.1290 · Cited by 13
Electrical characterisation of conductive hydrogels for biomedical applications
Briggs, E., Mendes, A. X., do Nascimento, A. T., Moulton, S. E., Blaker, J. J., & Cartmell, S. H. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.11.057 · Cited by 12
An Ultra-Low-Noise, Low Power and Miniaturized Dual-Channel Wireless Neural Recording Microsystem
Wang, H., Ma, Q., Chen, K., Zhang, H., Yang, Y., Zheng, N., & Hong, H. (2022) · Biosensors · doi:10.3390/bios12080613 · Cited by 12
“The electrical neural recording has an incomparable ultra-high resolution in temporal scale, is well established for basic science and clinical research, and there are more approaches to realize the miniaturization of equipment [10–12].”
Soltani, N., Jafari, H. M., Abdelhalim, K., Kassiri, H., Liu, X., & Genov, R. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3225304 · Cited by 12
“applications [2], while maintaining flexibility and generality as needed to accommodate multiple applications.”
BackgroundSelf-citationColloidal Perspective on Targeted Drug Delivery to the Central Nervous System
Wang, W., Hassan, M. M., & Mao, G. (2023) · Langmuir · doi:10.1021/acs.langmuir.2c02949 · Cited by 12
Zhu, L., Zhou, Z., Wang, W., Xie, S., Meng, Q., & Wang, Z. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3311465 · Cited by 13
“1(b), have a relatively low amplitude with a low frequency range [32].”
BackgroundHou, Y., Zhu, Y. S., Ji, X., Richardson, A. G., & Liu, X. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3355809 · Cited by 13
“Specifically, V A , V B , and the potential just before the end of the stimulation phase V C are measured to estimate the electrode impedance using a simplified electrode-tissue interface model [17].”
MethodSelf-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“To address lower stimulation efficiency, switched-capacitor stimulating topologies have been developed to maintain high efficiency with adequate control over the charge; however, the circuit implementation requires large capacitors, which may exceed the available area of an implantable device [8].”
Wireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
Flexible and smart electronics for single-cell resolved brain–machine interfaces
Lee, A. J., Wang, W., & Liu, J. (2023) · Applied Physics Reviews · doi:10.1063/5.0115879 · Cited by 11
Wei, Z., Jin, F., Li, T., He, Y., Qian, L., Ma, J., Yuan, T., Yu, X., Zheng, W., Javanmardi, N., et al. (2025) · ACS Nano · doi:10.1021/acsnano.4c14320 · Cited by 11
A Wireless ECoG Recording System to Detect Brain Responses to Tactile Stimulation
Lee, K. J., Hong, D., Jang, J., Lee, K. Y., Park, B., Kim, J.-H., Kim, J. S., & Kim, S. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3272630 · Cited by 12
“potentials (APs) range in frequencies of 1–10 kHz [25].”
BackgroundSuzuki, Y., Hu, Q., Batchelor, B. L., Voit, W., & Ecker, M. (2022) · Smart Materials and Structures · doi:10.1088/1361-665x/aca576 · Cited by 11
Ding, Y., Kuai, Y., Li, R.-L., Xu, X., Wang, B., Wang, Z., Liu, Y., Dong, Y., Chen, S., Guo, M., et al. (2025) · Advanced Science · doi:10.1002/advs.202509545 · Cited by 11
Multi‐Channel Neural Interface for Neural Recording and Neuromodulation
Kim, E.-M., Chung, W. G., Kim, E., Oh, M., Paek, J., Lee, T., Kim, D., An, S. H., Kim, S., & Park, J. (2025) · Small Methods · doi:10.1002/smtd.202501227 · Cited by 9
Usman, M., Ashebir, S. E., Okey-Mbata, C., Yun, Y., & Kim, S. (2025) · Applied Sciences · doi:10.3390/app152111316 · Cited by 9
“Neural interfaces are bioelectronic systems that establish direct communication links between nervous system functions and digital technology platforms [92].”
Chen, Y., Ding, Y., Lin, H., & Shi, J. (2026) · Chemical Society Reviews · doi:10.1039/d5cs01323b · Cited by 11
Cepstral Analysis-Based Artifact Detection, Recognition, and Removal for Prefrontal EEG
Han, S., Zhang, C., Lei, J., Han, Q., Du, Y., Wang, A., Bai, S., & Zhang, M. (2023) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2023.3266594 · Cited by 11
Self-citationTransparent Intracellular Sensing Platform with Si Needles for Simultaneous Live Imaging
Park, W., Kim, E. M., Jeon, Y., Lee, J., Yi, J., Jeong, J., Kim, B., Jeong, B. G., Kim, D. R., Kong, H., et al. (2023) · ACS Nano · doi:10.1021/acsnano.3c07527 · Cited by 9
Habli, Z. S., Lahoud, R., Zantout, A., Abou-Kheir, W. G., & Khraiche, M. L. (2024) · Lab on a Chip · doi:10.1039/d3lc00984j · Cited by 9
Combining SNNs with filtering for efficient neural decoding in implantable brain-machine interfaces
Zhou, B., Sun, P.-S. V., & Basu, A. (2025) · Neuromorphic Computing and Engineering · doi:10.1088/2634-4386/adba82 · Cited by 12
“The majority of clinical iBMI systems have a wired connection from the implant to the outside world [1] that restrict’s the user’s mobility.”
InfluentialBridging the gap — biomimetic design of bioelectronic interfaces
Promiński, A., & Tian, B. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.005 · Cited by 11
Kim, G., Hong, Y., Lee, H., Kim, M., Eun, J., Lee, J., Lee, S., Chou, N., & Shin, H. (2025) · Small Methods · doi:10.1002/smtd.202501384 · Cited by 10
Extreme manufacturing of minimally invasive intracortical neural electrodes
Xu, M., Zhu, Z., Ma, H., Zhou, G., Iliasov, A., Chen, Z., Tsang, W. M., Wu, J., Li, C., Wei, X., et al. (2025) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ae2579 · Cited by 11
3D‐Printable, Honeycomb‐Inspired Tissue‐Like Bioelectrodes for Patient‐Specific Neural Interface
Momin, M., Feng, L., Chen, X., Ahmed, S., AlMahmood, B., Huang, L., Ren, J., Wang, X., Lee, H., Cramer, S. R., et al. (2026) · Advanced Materials · doi:10.1002/adma.202516291 · Cited by 9
“Conventional neural interfaces, including multi-channel elec-trocorticography (ECoG) systems [ 14, 15], often rely on rigid, lithography-fabricated electrodes standardized for mass production [16–18].”
Jain, A., Fogleman, E., Botros, P., Vatsyayan, R., Koruprolu, A., Pochet, C., Bourhis, A. M., Liu, Z., Chethan, S., Le, H., et al. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3508544 · Cited by 9
“These neural signals have spectral content from 1 mHz to 10 kHz with peak amplitudes up to 10 mV pp [9], requiring less than 10 µ V rms noise from the front end [10].”
Double‐Sided, Thin‐Film Microelectrode Array with Hemispheric Electrodes for Subretinal Stimulation
Kim, N., Hong, Y., Cha, S., Kang, Y. N., Seo, H. W., Moon, H., Ahn, J., Intisar, A., Kim, M. S., Kim, S., et al. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202302155 · Cited by 8
Micro-patterned cellulose films for flexible electrodes in medical implants
Joodaki, M., Müller, B., Schift, H., Nallathambi, A., & Osmani, B. (2022) · Micro and Nano Engineering · doi:10.1016/j.mne.2022.100162 · Cited by 8
Shin, C. J., Lee, K., Langford, L., & Bai, W. (2025) · Small Methods · doi:10.1002/smtd.202501330 · Cited by 10
Kim, K., Jeong, J. Y., Shin, J. H., & Kim, T. (2025) · Small Methods · doi:10.1002/smtd.202501708 · Cited by 11
Flexible wide-range, sensitive three-axis pressure sensor array for robotic grasping feedback
Yin, M., Guo, Y., An, J. W., Liu, T., Gou, G., Li, T., Chen, G., Ma, T., Sun, J., Han, M., et al. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100250 · Cited by 13
Artificially Intelligent Closed-Loop Neurostimulators: Trade-Offs between Local and Remote Computing
Filho, J. S., Kassiri, H., Liu, X., & Genov, R. (2024) · Custom Integrated Circuits Conference · doi:10.1109/cicc60959.2024.10529029 · Cited by 11
“Depending on the required spatial resolution, and the level of tolerance of invasiveness, various methods of electroencephalography (EEG) recording can be employed [16].”
MethodSelf-citationDevelopment of an electrical current stimulator for controlling biohybrid machines
Collu, R., Fuentes, J., Lezcano, M. F., Crespo‐Cuadrado, M., Bartolucci, A., Ricotti, L., Vannozzi, L., Sánchez, S., Lai, S., & Barbaro, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-06465-0 · Cited by 9
A biosensor that learns on the go
Tam, S., & Gosselin, B. J. (2021) · Nature Electronics · doi:10.1038/s41928-020-00526-0 · Cited by 7
Lei, J., Wu, Y., Liu, X., Zhang, B., Pei, R., Zhang, Y., Ma, X., & Zhang, M. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3580081 · Cited by 8
“By recording and modulating neural activities, these devices have become invaluable tools in neuroscience research and clinical applications [1], [2].”
Self-citationGraphene-based neural electrodes: from materials and device fabrication to properties
Doğan, M. Z., & Bayram, C. (2025) · Journal of Materials Chemistry B · doi:10.1039/d5tb01040c · Cited by 6
Abdulwahab, S., Khleaf, H. K., & Jasim, M. H. (2021) · Engineering and Technology Journal · doi:10.30684/etj.v39i7.1854 · Cited by 7
“Even with well pre-possessed EEG data, the BCI has limitations when the brain is used by itself to control the robot [5], [6].”
MethodSaleNet: A low-power end-to-end CNN accelerator for sustained attention level evaluation using EEG
Zhang, C., Tang, Z., Guo, T., Lei, J., Xiao, J., Wang, A., Bai, S., & Zhang, M. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937323 · Cited by 6
“INTRODUCTION Brain-machine interfaces (BMIs) aim to establish an efficient communication channel between the human brain and the external world [1].”
BackgroundSelf-citationSong, H., Liu, Y., Li, J., Liu, Z., Yang, A., Lu, B., Zhou, Y., Duan, J., Li, J., He, J., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202407537 · Cited by 6
Integrating living biomaterials into neuroelectronic systems
Hong, M., Ye, Y., Kim, J., Kim, J., Rah, J., & Tchoe, Y. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00557-0 · Cited by 8
“Brain interface technol - ogy has advanced for decades to capture reliable local-field potentials and single-unit spikes from host neurons [ 34].”
Brain Extracellular Matrix-Based Electronic Brain Biochip
Liu, X., Dong, R., Hang, C., Lim, C. T., & Jiang, X. (2026) · ACS Nano · doi:10.1021/acsnano.5c21848 · Cited by 5
Self-citationFlexible a‐IGZO TFT‐Based Circuit for Active Addressing in Neural Stimulation Electrode Arrays
Rodríguez-Lopez, O., Rocha-Flores, P. E., Maeng, J., Cogan, S. F., Pancrazio, J. J., Tamil, L. S., Voit, W., & Gutiérrez‐Heredia, G. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202301046 · Cited by 6
Cai, Y., Wang, F., Yang, L., Chen, L., Ying, J., Liu, Z., Wang, G., Ma, C., & Liu, J. (2024) · Journal of Materials Chemistry C · doi:10.1039/d4tc02801e · Cited by 5
Ma, H., Wang, Z., Pan, M., Hu, F., Sun, G., & He, X. (2025) · APL Materials · doi:10.1063/5.0272616 · Cited by 6
Directional Growth of cm-Long PLGA Nanofibers by a Simple and Fast Wet-Processing Method
Betz-Güttner, E., Righi, M., Micera, S., & Fraleoni‐Morgera, A. (2022) · Materials · doi:10.3390/ma15020687 · Cited by 5
Jafari, H. M., Liu, X., & Genov, R. (2023) · IEEE Open Journal of the Solid-State Circuits Society · doi:10.1109/ojsscs.2023.3236305 · Cited by 5
“Recently, several CMOS system-on-chip (SoC) designs for amperometric electrochemical DNA analysis have been developed [3], [4], [5], [6], [7], [8], [9], [10].”
BackgroundSelf-citationRecent progress on integrated neuromorphic chips
Gu, X., Bian, L., Lu, C., Song, C., Wang, Y., Zhang, J., & Zhao, Y. (2026) · The Innovation Informatics · doi:10.59717/j.xinn-inform.2026.100027 · Cited by 5
Hwang, S., Hwang, Y., Kim, D., Lee, J., Choe, H. K., Lee, J., Kang, H., & Kung, J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1161592 · Cited by 4
Cho, W., Jung, M., Yoon, S.-H., Jeon, J., Oh, M., Kim, J. Y., Park, M.-J., Kang, C. M., & Chung, T. D. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c13829 · Cited by 5
Gao, S., & Lei, T. (2025) · Scientia Sinica Chimica · doi:10.1360/ssc-2025-0083 · Cited by 5
Xu, J., Shirinkami, H., Hwang, S., Jeong, H. S., Kim, G., Jun, S. B., & Chun, H. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c21649 · Cited by 4
Invasive Brain Signal Acquisition Techniques: SUA, MUA, LFP, ECoG in Neuroimaging and Recording
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-76081-5_3 · Cited by 3
Ding, Q., Tong, C., Liu, D., Yan, B., Wang, F., & Han, S. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3556726 · Cited by 3
“Principles of proprioception [4]. nerves of amputees through neural interfaces, thereby restoring the natural flow of proprioceptive information [11], [12].”
Ultrasound-transparent neural interfaces for multimodal interaction
Panskus, R., Velea, A. I., Holzapfel, L., Pavlou, C., Li, Q. P., Qin, C., Nelissen, F., Waasdorp, R., Maresca, D., Gazzola, V., et al. (2026) · npj Flexible Electronics · doi:10.1038/s41528-025-00517-1 · Cited by 5
“Moreover, the resulting artifacts are typically confined to ultrasonic frequencies and therefore well outside the frequency range of the neuronal signals 59 , making them likely to affect low-frequency electrophysiological data.”
Won, C., Cho, Y. U., Kweon, S., Cho, S., Kwon, C., Kim, H. W., Lee, J. Y., Park, S. H., Han, S., Kim, Y. W., et al. (2026) · Science Advances · doi:10.1126/sciadv.aee2754 · Cited by 3
“The design of these interfaces enables the recording of intricate neural signals and high-precision delivery of therapeutic electrical stimulation ( 3 , 4 ).”
Chemically communicating with the brain through artificial neurons
(2022) · Nature Electronics · doi:10.1038/s41928-022-00806-x · Cited by 3
GHz ultrasonic sensor for ionic content with high sensitivity and localization
Balasubramanian, P. S., & Lal, A. (2023) · iScience · doi:10.1016/j.isci.2023.106907 · Cited by 3
A 16-channel Si probe monolithically integrated with CMOS chips for neural recording
Gou, G., You, C., Yao, P., Guo, Y.-S., Liu, T.-Z., Song, Z., He, B.-Y., Yin, M., Zhang, X., Liu, C., et al. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100206 · Cited by 3
Kang, V., Malak, A. A., Lau, K. S. K., Zhu, Y., Morshead, C. M., & Liu, X. (2023) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas46773.2023.10181551 · Cited by 3
“Electric fields can be generated using invasive electrodes for the treatment of a variety of neurological conditions via activating endogenous neural stem cells [2], [3].”
BackgroundSelf-citationAn 112-Ch Neural Signal Acquisition SoC With Full-Channel Read-Out and Processing Accelerators
Tang, Z., Guo, Y., Zheng, M., Sun, C., Wu, Y., Fang, R., Fang, Y. Z., & Zhang, M. (2024) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2024.3396774 · Cited by 3
“Recent custom-designed multichannel neural signal acquisition chips provide optimized solutions for frontier neuroscience study, offering reduced power consumption, miniaturized volume, and improved signal quality and tailored features for specific experimental needs [5].”
BackgroundSelf-citationXu, T. (2024) · Chemical Communications · doi:10.1039/d4cc01867b · Cited by 3
Jang, L., Kim, J.-H., Lee, W., Lee, J., Oh, G.-G., Jung, H., Kim, S., Jeon, D., Ha, T.-Y., Chang, K.-A., et al. (2025) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c01974 · Cited by 3
A Review of MXene Memristive Networks: Atomic‐Scale Engineering to Neuromorphic System Integration
Yang, S., Wang, J., Tan, D., Sun, N., Shi, H., Bi, S., & Jiang, C. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500685 · Cited by 2
Engineering aspects and materials for next generation neural implants
Mahato, K. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.07.001 · Cited by 2
Neural Interfaces: Applications, Innovative Approaches, Biocompatibility, Biomimetics
Zemlyanskov, M. S., Arsentiev, K. A., Shtol, V. S., Konovalova, S. P., Grinevich, V. P., & Евгеньевич, М. П. (2025) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093025040118 · Cited by 2
“LFPs represent recordings of synchronized activity from small groups of neurons (e.g., obtained via implanted electrodes), offering even a higher spatial resolution than EEG and ECoG signals [17, 19].”
Kim, Y., Lee, J., Kil, J., Kim, D. J., Jeong, T., & Lee, B. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00564-1 · Cited by 3
Maughan, J., Woods, I., O’Connor, C., Quintana-Sarti, P., Caffrey, E., Munuera, J., Carey, T., Dervan, A. G., Valdés, A. L., Mamad, O., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505076 · Cited by 2
Trzpil-Jurgielewicz, B., Dąbrowski, W., & Hottowy, P. (2021) · Sensors · doi:10.3390/s21093116 · Cited by 2
“Many designs based on this circuit idea, with excellent noise performance and low power consumption, have been reported; for a review see [29,30].”
BackgroundCognitive neural prosthetics – the way from experiment to clinical application
Kravchenko, S. V., Каде, А. Х., Трофименко, А. И., Вчерашнюк, С. П., & Malyshko, V. V. (2021) · Innovative medicine of Kuban · doi:10.35401/2500-0268-2021-23-3-64-72 · Cited by 3
Mazzetti, P., & Carbone, A. (2022) · Algorithms · doi:10.3390/a15110396 · Cited by 2
Single-channel EEG completion using Cascade Transformer
Zhang, C., Han, S., & Zhang, M. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948557 · Cited by 3
“A brain-machine interface (BMI) aims to establish a direct communication pathway between the nervous system of living creature and the external machine [1, 2].”
BackgroundSelf-citationChemically Mediated Artificial Neuron
Tian, Y., Cai, K., Zhao, X. Q., & Wang, T. (2022) · IEEE International Flexible Electronics Technology Conference (IFETC) · doi:10.1109/ifetc53656.2022.9948474 · Cited by 2
Reynolds-Cuéllar, P., & Salazar-Gómez, A. F. (2023) · ACM/IEEE International Conference on Human-Robot Interaction (HRI) · doi:10.1145/3568294.3580034 · Cited by 3
Mxene/Polydimethylsiloxane (PDMS) Based Implantable and Flexible Bioelectrodes for Neural Sensing
Khan, K. R. B., Al–Othman, A., Al-Nashash, H. A., & Al-Sayah, M. H. (2023) · Advances in Science and Engineering Technology International Conferences (ASET) · doi:10.1109/aset56582.2023.10180745 · Cited by 3
“Ever since bioelectricity was discovered it has served to efficiently monitor and understand the electrophysiological functions and properties of biological tissues by electronic devices [1].”
BackgroundMulti-channel Wireless Implantable Brain-Computer Interface System
Lin, C., Han, C. H., Mao, J., Yu, S. P., & Zhang, Z. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340603 · Cited by 2
“Implantable brain-computer interface (BCI) has developed rapidly in recent years by advances in flexible electronics and bio-compatible materials [1], which has made substantial contributions in the following three main applications.”
BackgroundMEDSA: A Memristive-passive Delta-Sigma ADC Circuit for Detecting Neural Signals
You, H., Xu, J., Amirsoleimani, A., Azghadi, M. R., & Genov, R. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389106 · Cited by 2
“This is particularly problematic in the context of neural signal detection, characterized by their low-amplitude and low-frequency nature [5], [6].”
BackgroundHigh-Porosity Sieve-Type Neural Electrodes for Motor Function Recovery and Nerve Signal Acquisition
Choi, W., Park, H., Oh, S., Seok, S., Yoon, D. S., & Kim, J. (2024) · Micromachines · doi:10.3390/mi15070862 · Cited by 2
Reconfigurable dielectric engineered WSe2/HZO mem-transistor
Tong, T., He, Y., Gao, Y., Liu, Y., Liao, K., & Li, W. (2024) · 2D Materials · doi:10.1088/2053-1583/ad70c9 · Cited by 2
Multifunctional neural probe for synchronized monitoring multiple brain signals
Cao, J., Wang, L., Tu, K., Xu, Q., Xu, M., Chen, H., Wang, X., Yang, B., & Liu, J. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116572 · Cited by 2
Qu, Y. N., Kong, X., Shen, S., Zhang, A., Bình, H. T. T., & Gao, L. (2025) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2025.3571956 · Cited by 2
“T HE RAPID proliferation of consumer electronics systems in our daily lives has led to an unprecedented accumulation of personal and sensitive data [1].”
Bo, W., Che, R., Jia, F., Sun, K., Liu, Q., Guo, L., Zhang, X., & Gong, Y. (2025) · Research · doi:10.34133/research.0755 · Cited by 2
“…via nerve cell membrane ion transport pathways as well as the accompanying generated electromagnetic signals are the bases for the information transmission and processing of human brain intelligence [ 23 – 26 ] and the information communication via brain–machine interfaces [ 11 – 13 , 27 , 28 ].”
Advances and Perspectives on Organic Materials for Neuroelectronic Interface Devices★
Jia, L., Zhan, Z., He, Z., Di, C., & Zhu, D. (2023) · 化学学报 · doi:10.6023/a23050213 · Cited by 3
Mneimneh, M., Quadir, N. A., & Albasha, L. (2024) · IEEE Access · doi:10.1109/access.2024.3441840 · Cited by 1
“Implantable neural devices are still under clinical studies where there is no further understanding of the communication system between the nerve and the interfaced device in terms of medical view, especially for severed nerves as well as the long-term implantation effect [84].”
BackgroundDesign and Modeling of Magnetoelectric Micro-Particles for Neuromodulation
Narayanan, R. P., & Khaleghi, A. (2024) · International Conference on Electromagnetics in Advanced Applications (ICEAA) · doi:10.1109/iceaa61917.2024.10701829 · Cited by 1
“Neurostimulation encompasses various therapies that utilize electrical stimulation to modulate neural function [1], [2], [3].”
Reliable transfer enabled by UV-curable stamp with tunable rigidity
Chen, L., Niu, Y., Liu, C., Fan, R., Liu, P., Ma, D., Zhang, X., Liu, C., & Duan, H. (2024) · Surfaces and Interfaces · doi:10.1016/j.surfin.2024.105348 · Cited by 1
Kim, T., Liu, H., Huang, C.-T., Wu, I., & Liu, X. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11589048 · Cited by 4
“Monitoring brain activity is critical to diagnosing neurological disorders and enhancing our understanding of human cognitive functions [1].”
Self-citationHu, D., Wang, H., Gao, F., Lou, X., Xie, Z., & Cao, J. (2025) · The Journal of Supercomputing · doi:10.1007/s11227-025-07932-1 · Cited by 1
Rokade, K. A., Bagade, A. A., Patil, S. A., Halagale, P. D., Rananavare, A. P., Jeffery, A. A., Ahn, Y.-H., & Dongale, T. D. (2025) · Materials Today Communications · doi:10.1016/j.mtcomm.2025.114341 · Cited by 2
Advance design for brain-inspired flexible computing: Materials, structures, models to applications
Cao, Y., Chung, K. Y., Guan, X., Chen, Y., Tian, X., Fan, X., Fu, H., & Xu, B. (2026) · Materials Today · doi:10.1016/j.mattod.2026.103262 · Cited by 1
Huang, J., Li, W., Zhou, Y., Wei, L., & Dong, C. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00580-2 · Cited by 2
“Multimaterial and multifunctional fi ber technologies have emerged as a powerful platform to address these requirements, offering fl exible, soft, and highly integrated probes capable of electrical, optical, chemical, and micro fl uidic functions within a single miniaturized strand 38,77,131,132 .”
Advances in neuroprostheses: interfaces, materials, and applications
He, E., Chen, K., Liu, S., Chen, H., Xiao, Y., Chen, R., Tu, P., Pan, G., & Lin, P. (2026) · Nano Convergence · doi:10.1186/s40580-026-00552-2 · Cited by 1
“Key research priorities include optimizing electrochemical properties, such as high charge-injection capacity and low interfacial impedance, while concurrently ensuring chemical stability to prevent coating degradation and biocompatibility to avoid neurotoxic effects [112].”
Impact of ClockΔ19 mutation on neural recording performance and neural inflammatory responses
Dhawan, V., Narayanan, S., Thompson, C. H., Shi, D., Patel, Y., McClung, C. A., & Cui, X. T. (2026) · Biomaterials · doi:10.1016/j.biomaterials.2026.124369 · Cited by 1
Active devices and systems for closed-loop neuromodulation
Wang, J., Xue, H., Li, J., Li, Y., Li, R., Mei, Y., & Song, E. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01357-3 · Cited by 1
Long, L. P., Hao, V. T. K., & Nguyen, T. N. (2026) · iScience · doi:10.1016/j.isci.2026.117083 · Cited by 1
“161 Such technologies are pivotal in the future of brain-machine interfaces (BMIs) to help patients with neurological disorders or injuries regain their sensory and motor activities.”
Dominguez, A. L., González‐Mayorga, A., López‐Dolado, E., & Serrano, M. C. (2021) · Springer eBooks · doi:10.1007/978-3-030-81400-7_1 · Cited by 2
Integrated Sensing Devices for Brain-Computer Interfaces
Do, T., Duong, N. M. H., & Lin, C. (2023) · Springer eBooks · doi:10.1007/978-3-031-21610-7_7 · Cited by 2
Metadata
- Authors
- Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J.
- Affiliations
- Tsinghua University (CN)
- University of Pennsylvania (US)
- Corresponding author
- Zhang, Milin
- Venue
- Nature Electronics
- Published
- 2020-04-13
- Volume
- 3
- Issue
- 4
- Pages
- 191-200
- ISSN
- 2520-1131 (ISSN-L)
- OpenAlex
- W3015809619
- Cited by
- 231
- References
- 138
- Citations by year
- 2026: 24 · 2025: 52 · 2024: 53 · 2023: 47 · 2022: 27 · 2021: 24 · 2020: 4
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (61674095)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- neural signal processing, patch clamp, implantable neural interfaces, neural sensing, human-machine communication
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.