Electronic neural interfaces
The DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The former is less invasiveness and easier to implant. But the latter one have a better stimulation effect.[547]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [547]
In the citing paper
“Current-controlled stimulation can specify the injected charge, improving safety and efficacy, though at the cost of lower efficiency.”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [8]
In the citing paper
“To address lower stimulation efficiency, switched-capacitor stimulating topologies have been developed to maintain high efficiency with adequate control over the charge; however, the circuit implementation requires large capacitors, which may exceed the available area of an implantable device [8].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [8]
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Single-channel currents recorded from membrane of denervated frog muscle fibres
NEHER, E., & SAKMANN, B. (1976) · Nature · doi:10.1038/260799a0 · Cited by 2,570
Currents carried by sodium and potassium ions through the membrane of the giant axon of Loligo
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004717 · Cited by 2,491
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Transcranial Magnetic Stimulation: A Primer
Hallett, M. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.026 · Cited by 1,891
Research works printed but not linked: 1
- Rozgić, D. et al. A 0.338cm3, artifact-free, 64-contact neuromodulation platform for simultaneous stimulation and sensing. IEEE Trans. Biomed. Circ. Syst. 13, 38–55 (2018).
Cited by
Items 201–237 of 237
A Comprehensive Study Of Metaverse Privacy And Security
Jacob, A. O., Biju, A., Sibichen, B. R., Varghese, C. R., & Varghese, A. R. (2023) · International Journal of Engineering Technology and Management Sciences · doi:10.46647/ijetms.2023.v07i04.059 · Cited by 1
Nicolini, G., Fava, A., Centurelli, F., & Scotti, G. (2024) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea14030038 · Cited by 1
“Although affordable and safe to perform, such techniques are hampered by limited spatial and temporal resolutions and exhibit a low signal-to-noise ratio (SNR) due to the filtering effect of the intermediate layers between the scalp and the source of the bio-signals [10,11].”
BackgroundExtreme Mechanics of Hydrogels Toward In Situ Hydrogel Bioelectronics
Wong, T. H., Zhao, X., & Lin, S. (2024) · Wiley eBooks · doi:10.1002/9783527842308.ch1 · Cited by 1
Li, M., Xu, W., Xu, Z., Mo, F., Yang, G., Lv, S., Cao, H., Liu, J., & Cai, X. (2024) · Electronics Letters · doi:10.1049/ell2.70013 · Cited by 1
“Microelectrode arrays (MEA) stand out for their ability to capture neural activities with high precision as brain–computer interface (BCI) [12, 13].”
Zhou, Z., Zhu, L., Wang, W., Xie, S., Zhou, Y., Su, R., Zheng, J., Zhu, Z., Luo, F., Warr, P. A., et al. (2025) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2025.3528014 · Cited by 1
“For instance, a high spatial resolution electromyography (EMG) detection studies the electrical behavior of the motor function for the muscle tissues, to increase the degrees of freedom for prosthetic control [6], [7], [8], [9].”
Study on Compressed Sensing of Action PotentialPreprint
Park, H., & Liu, X. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2102.00284
“Action potential is typically recorded at ten of kilohertz [1].”
BackgroundSelf-citationMind-Media System: A Consumer-Grade Brain-Computer Interface System for Media Applications
Liu, C., Zhou, Y., & Yu, D. (2022) · Smart innovation, systems and technologies · doi:10.1007/978-981-16-8048-9_8
Liang, S. (2021) · Digital Repository Service (Northeastern University) · doi:10.17760/d20409217
Subeh, I. (2022) · Studies in systems, decision and control · doi:10.1007/978-3-031-10212-7_59
Which Ethical Issues Need to Be Considered Related to Microwires or Utah Arrays?
Young, M. J. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_7 · Cited by 1
Developing Artificial Sensory Neurons for Large-Area Hybrid Electronics
Ng, S. E. (2024) · World Scientific Annual Review of Functional Materials · doi:10.1142/s2810922824300034
Political Neurotargeting: Ethical Challenges of Exploiting Intimate Data in Democratic ProcessesPreprint
García, C. S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4886089 · Cited by 1
Design and realization of a miniature high-bandwidth implantable brain-computer interface system
Junjie, T., Jin, W., Haochuan, W., Hanqing, Z., & Hui, H. (2024) · International Conference on Electronic Information Engineering, Big Data and Computer Technology (EIBDCT) · doi:10.1117/12.3031111
“…between the brain and external devices, BCI realizes the deep integration of the brain and the machine in a multilevel, bidirectional closed-loop [1] , which not only changes the traditional brain-computer communication that needs to rely on the muscles and the nervous system, but also produces…”
Efficient Metastability Mitigation and Sub-Band Filtering in VCO-Based EEG Recording
Tang, Z., Sun, C., Ma, Y., Zheng, M., Zhang, C., Ma, Z., Wang, T. A., & Zhang, M. (2024) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2024.3446187
“T HE RECORDING of EEG signals imposes stringent requirements on circuit designs, necessitating low-noise and power-efficient solutions [1].”
Self-citationEnhancement-Mode Ionic Transistor Architecture with an Entirely Ionic Gating Mechanism
Hassanpour, F., Kling, M., Negley, H., Hashemi, N. N., & Montazami, R. (2025) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.5c00125
Development and challenges of implantable neural electrodes in brain-computer interface technology
Tian, Y., Wang, A., Jing, Y., & Bai, S. (2025) · Scientia Sinica Chimica · doi:10.1360/ssc-2025-0107
Li, X., Ahmed, Z., Gupta, H., Sarna, K., Jain, V., & Chamanzar, M. (2024) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2024.5
Lin, X., Wang, B., Liu, L., Zhou, X., Yang, W., & Wang, H. (2025) · Circuits Systems and Signal Processing · doi:10.1007/s00034-025-03268-6
“The LFP includes lower-frequency neural waveforms in the range of 1–200 Hz with a peak amplitude of about 1 mV [ 31].”
Real-Time Artifact Suppression in Neuromodulation: A Model-Based Approach
Salimpour, Y., Arginteanu, T., Wyse‐Sookoo, K., Mills, K. A., & Anderson, W. S. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253281
“Neuromodulation systems must be able to actively remove artifacts from the digitized signals to perform real-time biomarker computation while simultaneously recording continuous brain activity [7].”
Nanosensors in Neural Health and Brain–Machine Interfaces
Raj, A., Yadav, S., Sehrawat, N., & Yadav, S. (2025) · Smart nanomaterials technology · doi:10.1007/978-981-96-6091-9_13
Digital Systems for Closed-Loop Neuromodulation Research
Ramesh, R. (2023) · TSpace (University of Toronto)
Liquid Metal-Enabled High-Robustness MEMS Flexible Neural Interface for Chronic Cortical Recording
Lai, S., Peng, C., Tao, T. H., & Zhou, Z. (2026) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems64181.2026.11419427
“Flexible neural interfaces constitute a critical technology for brain-computer interfaces (BCIs), serving as the primary conduit for acquiring high-fidelity electrophysiological signals from neural tissues [1,2].”
Eccentric Strain Sensor Arrays for Shear Force Sensing
Gao, Y., & Yu, X. (2025) · IEEE International Conference on Micro/Nano Sensors for AI, Healthcare, and Robotics (NSENS) · doi:10.1109/nsens65807.2025.11428056
Zhou, B., & Basu, A. (2026) · Neuromorphic Computing and Engineering · doi:10.1088/2634-4386/ae6728 · Cited by 2
“Implantable brain–machine interface (iBMI) depicted in figure 1(a) creates a connection between the brain and machines, serving as a promising technology for interpreting a patient’s intent to con-trol robotic arms [1], computer cursors [2], or an actuator [3].”
A modular, high-bandwidth, bidirectional implantable device for neural interrogation
Darie, R., Parker, S. R., Calvert, J. S., Tiwari, E., Abdelrahman, N. R., Syed, S. H., Shaaya, E. A., Fridley, J., Merlo, M. W., Halpern, I., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae7f52
“Neural interfaces have shown remarkable progress towards enabling the treatment of neurological disease, disorder, and injury [1].”
Research progress on MXene-based electrophysiological electrodes
Xinyun, L. I. N., Wenya, H. U., Song, D., & Nan, L. I. U. (2026) · Gongneng cailiao yu qijian xuebao · doi:10.3724/jfmd.2511093 · Cited by 1
Roadmap for neuromorphic organic devices
Lauro, M. D., Alibart, F., Bardagot, O., Belleri, P., Benwadih, M., Benyahia, A., Bongartz, L. M., Boys, A. J., Bruno, U., Caironi, M., et al. (2026) · Neuromorphic Computing and Engineering · doi:10.1088/2634-4386/ae9338 · Cited by 1
An artificial synapse-based neural interface with neurotransmitter-mediated communication function
Wang, M., Hao, H., Shi, L., & Zhu, Y. (2026) · Precision Manufacturing · doi:10.63823/pm2026070001
Bypass Injury with Memristive Intelligence: A Hardware-First Approach to Neural Repair
Matveeva, M., Mishchenko, M. A., Fedulina, A., Bolshakov, D. I., Bordanov, I., Владимирович, К. Л., Taran, D., Shchanikov, S., Mikhaylov, A. N., & Kazantsev, V. (2026) · BioNanoScience · doi:10.1007/s12668-026-02873-2
“In the future, neural interfaces that provide direct electrical communication between biologi - cal and artificial neural networks could become the primary channel for information exchange [33].”
Cai, R., Yang, B., Zheng, K., SHIN, S., Chen, W., Li, Y., Xiong, Y., & Hu, B. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.117144
Wireless bioelectronic control architectures for muscle-powered biohybrid robotic systems
Tetsuka, H., & Hirano, M. (2026) · APL Bioengineering · doi:10.1063/5.0339053
“36 Future development is better described as a branching design space than as a linear roadmap toward organoid integration.”
Galletta, V., Fiocchi, S., Verardo, C., Carbone, L., del Mercato, L. L., Romeni, S., & Chiaramello, E. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1951247
Insertion, biocompatibility and functionality of flexible neural implantable probes in vivo
Bartoletti, S., Ren, E., Raimondi, F., McGlynn, E., Cerezo-Sanchez, M., Casadei Garofani, B., Capodiferro, A., Heidari, H., & Curia, G. (2023) · IRIS UNIMORE (University of Modena and Reggio Emilia)
Neuromorphic Human Activity Recognition through LIF-based neurons
Vittorio, F., Enrico, M., & Gianvito, U. (2026) · PORTO@Iris
Riccardo, P., Vittorio, F., Forno, E., Enrico, M., & Gianvito, U. (2026) · PORTO@Iris
Kim, E., Kim, E., Lee, J., Jeong, I., Hong, Y., Oh, M., Lee, S., & Park, J. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71933
Metadata
- Authors
- Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J.
- Affiliations
- Tsinghua University (CN)
- University of Pennsylvania (US)
- Corresponding author
- Zhang, Milin
- Venue
- Nature Electronics
- Published
- 2020-04-13
- Volume
- 3
- Issue
- 4
- Pages
- 191-200
- ISSN
- 2520-1131 (ISSN-L)
- OpenAlex
- W3015809619
- Cited by
- 231
- References
- 138
- Citations by year
- 2026: 24 · 2025: 52 · 2024: 53 · 2023: 47 · 2022: 27 · 2021: 24 · 2020: 4
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (61674095)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- neural signal processing, patch clamp, implantable neural interfaces, neural sensing, human-machine communication
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.