The DOI matches its Crossref record; 60 of the 61 references it cites were found in a registry or an index.
Extended gate field-effect-transistor for sensing cortisol stress hormone
Open accessAbstract
Cortisol is a hormone released in response to stress and is a major glucocorticoid produced by adrenal glands. Here, we report a wearable sensory electronic chip using label-free detection, based on a platinum/graphene aptamer extended gate field effect transistor (EG-FET) for the recognition of cortisol in biological buffers within the Debye screening length. The device shows promising experimental features for real-time monitoring of the circadian rhythm of cortisol in human sweat. We report a hysteresis-free EG-FET with a voltage sensitivity of the order of 14 mV/decade and current sensitivity up to 80% over the four decades of cortisol concentration. The detection limit is 0.2 nM over a wide range, between 1 nM and 10 µM, of cortisol concentrations in physiological fluid, with negligible drift over time and high selectivity. The dynamic range fully covers those in human sweat. We propose a comprehensive analysis and a unified, predictive analytical mapping of current sensitivity in all regimes of operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Stress and the brain: from adaptation to disease
de Kloet, E. R., Joëls, M., & Holsboer, F. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1683 · Cited by 4,621
Stress and disorders of the stress system
Chrousos, G. P. (2009) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2009.106 · Cited by 3,215
The Concepts of Stress and Stress System Disorders: Overview of Physical and Behavioral Homeostasis
Chrousos, G. P. (1992) · JAMA · doi:10.1001/jama.1992.03480090092034 · Cited by 2,689
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Enz, C., Krummenacher, F., & Vittoz, E. A. (1995) · Analog Integrated Circuits and Signal Processing · doi:10.1007/bf01239381 · Cited by 1,272
Aptamers and Their Biological Applications
Song, K.-M., Lee, S., & Ban, C. (2012) · Sensors · doi:10.3390/s120100612 · Cited by 868
Reproducibility crisis: Blame it on the antibodies
Baker, M. (2015) · Nature · doi:10.1038/521274a · Cited by 830
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Enamel peptides reveal the sex of the Late Antique ‘Lovers of Modena’
Lugli, F., Rocco, G. D., Vazzana, A., Genovese, F., Pinetti, D., Cilli, E., Carile, M. C., Silvestrini, S., Gabanini, G., Arrighi, S., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49562-7 · Cited by 340
Ikenoue, T., Terakado, Y., Nakagawa, H., Hikiba, Y., Fujii, T., Matsubara, D., Noguchi, R., Zhu, C., Yamamoto, K., Kudo, Y., et al. (2017) · Scientific Reports · doi:10.1038/srep39567 · Cited by 331
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Intraindividual coupling of daily stress and cognition.
Sliwinski, M. J., Smyth, J. M., Hofer, S. M., & Stawski, R. S. (2006) · Psychology and Aging · doi:10.1037/0882-7974.21.3.545 · Cited by 306
Shinwari, M. W., Deen, M. J., & Landheer, D. (2006) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 273
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Dalirirad, S., & Steckl, A. J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.161 · Cited by 266
Chu, C.-H., Sarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chang, W.-H., Lee, G.-Y., Chyi, J., Chen, C.-C., Shiesh, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05426-6 · Cited by 248
Campos, R., Borme, J., Guerreiro, J. R. L., Machado, G., Cerqueira, M. F., Petrovykh, D. Y., & Alpuim, P. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00344 · Cited by 217
Chemical Sensors: An Introduction for Scientists and Engineers
Janata, J. (2010) · Cited by 198
Sanghavi, B. J., Moore, J. A., Chávez, J. L., Hagen, J. A., Kelley‐Loughnane, N., Chou, C., & Swami, N. S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.044 · Cited by 188
Carbon fiber based electrochemical sensor for sweat cortisol measurement
Sekar, M. K., Pandiaraj, M., Bhansali, S., Ponpandian, N., & Viswanathan, C. (2019) · Scientific Reports · doi:10.1038/s41598-018-37243-w · Cited by 167
Vabbina, P. K., Kaushik, A. K., Pokhrel, N., Bhansali, S., & Pala, N. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.026 · Cited by 155
Carbon nanotubes and graphene nano field-effect transistor-based biosensors
Tran, T., & Mulchandani, A. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.12.002 · Cited by 152
Highly sensitive palladium oxide thin film extended gate FETs as pH sensor
Das, A., Ko, D. H., Chen, C.-H., Chang, L., Lai, C., Chu, F.-C., Chow, L., & Lin, R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.08.057 · Cited by 142
Hansen, Å. M., Garde, A. H., Christensen, J., Eller, N. H., & Netterstrøm, B. (2003) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510310001942 · Cited by 120
Tuteja, S., Ormsby, C., & Neethirajan, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0193-5 · Cited by 119
Label-free, chemiresistor immunosensor for stress biomarker cortisol in saliva
Tlili, C., Myung, N. V., Shetty, V., & Mulchandani, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.045 · Cited by 117
Jo, S., Lee, W., Park, J., Kim, W., Kim, W., Lee, G., Lee, H., Hong, J., & Park, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127424 · Cited by 98
Field effect detection of biomolecular interactions
Estrela, P., Stewart, A., Yan, F., & Migliorato, P. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.075 · Cited by 92
Surface plasmon resonance immunosensor for cortisol and cortisone determination
Frasconi, M., Mazzarino, M., Botrè, F., & Mazzei, F. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2914-6 · Cited by 81
Electrochemical Sensing of Cortisol: A Recent Update
Singh, A., Kaushik, A. K., Kumar, R., Nair, M. G., & Bhansali, S. (2014) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-014-0894-2 · Cited by 80
Jang, H.-J., Lee, T., Song, J., Russell, L., Li, H., Dailey, J., Searson, P. C., & Katz, H. E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18855 · Cited by 80
Mitchell, J. S., Lowe, T. E., & Ingram, J. R. (2008) · The Analyst · doi:10.1039/b817083p · Cited by 79
Jayant, R. D., Yndart, A., Sagar, V., Bhansali, S., Nair, M. G., Kaushik, A. K., & Atluri, V. S. R. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s75514 · Cited by 78
Direct immune-detection of cortisol by chemiresistor graphene oxide sensor
Kim, Y., Lee, K., Jung, H., Kang, H. K., Jo, J., Park, I., & Lee, H. H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.017 · Cited by 75
Flexible ISFET Biosensor Using IGZO Metal Oxide TFTs and an ITO Sensing Layer
Smith, J. T., Shah, S. S., Goryll, M., Stowell, J. R., & Allee, D. R. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2295057 · Cited by 74
Fernandez, R. E., Umasankar, Y., Manickam, P., Nickel, J. C., Iwasaki, L. R., Kawamoto, B., Todoki, K. C., Scott, J. M., & Bhansali, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-17835-8 · Cited by 74 · cited 5×
“The models of Equation (2) and Equation (S3) show very good accuracy.”
BackgroundMethodInfluentialReconfigurable Carbon Nanotube Multiplexed Sensing Devices
Xu, X., Clément, P., Eklӧf, J., Kelley‐Loughnane, N., Moth‐Poulsen, K., Chávez, J. L., & Palma, M. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b00856 · Cited by 73
Adam, E. K. (2012) · Monographs of the Society for Research in Child Development · doi:10.1111/j.1540-5834.2012.00657.x · Cited by 68
Stability and predictors of change in salivary cortisol measures over six years: MESA
Wang, X., Sánchez, B. N., Golden, S. H., Shrager, S., Kirschbaum, C., Karlamangla, A. S., Seeman, T. E., & Roux, A. V. D. (2014) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2014.07.024 · Cited by 66
Kim, K. S., Ryeol, L. S., Kim, S., Lee, J. Y., Chung, C., Choe, W., & Yoo, P. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.135 · Cited by 66
Dielectric-Modulated Field Effect Transistors for DNA Detection: Impact of DNA Orientation
Kalra, S., Kumar, M. J., & Dhawan, A. (2016) · IEEE Electron Device Letters · doi:10.1109/led.2016.2613110 · Cited by 65
Palit, S., Singh, K., Lou, B., Her, J.-L., Pang, S., & Pan, T.-M. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.127850 · Cited by 58
Graphene oxide surface blocking agents can increase the DNA biosensor sensitivity
Liu, B., Huang, P. J., Kelly, E. Y., & Liu, J. (2016) · Biotechnology Journal · doi:10.1002/biot.201500540 · Cited by 55
Iskierko, Z., Sosnowska, M., Sharma, P. S., Benincori, T., D'Souza, F. W., Kamińska, I., Fronc, K., & Noworyta, K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.073 · Cited by 51
A fluorimetric assay for cortisol
Appel, D., Schmid, R. D., Drăgan, C.-A., Bureik, M., & Urlacher, V. B. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0022-9 · Cited by 51
Selection of high affinity aptamer-ligand for dexamethasone and its electrochemical biosensor
Mehennaoui, S., Poorahong, S., Jiménez, G. C., & Siaj, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-42671-3 · Cited by 51
Cortisol, Cushing's Syndrome, and a Shrinking Brain--New Evidence for Reversibility
McEwen, B. S. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.5.9999 · Cited by 47
Comparative Study of Field Effect Transistor Based Biosensors
Moon, D., Han, J., & Meyyappan, M. (2016) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2016.2615855 · Cited by 44
Fabrication of N-doped multidimensional carbon nanofibers for high-performance cortisol biosensors
Jeong, G., Oh, J., & Jang, J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.061 · Cited by 43
Synthesis of MUC1 aptamer-stabilized gold nanoclusters for cell-specific imaging
Feng, B., Xing, Y., Lan, J., Su, Z., & Wang, F. (2020) · Talanta · doi:10.1016/j.talanta.2020.120796 · Cited by 41
Real-time aptamer quantum dot fluorescent flow sensor
Bogomolova, A., & Aldissi, M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.001 · Cited by 37
Wang, Z., Xie, Z., Cui, G., Liu, L., Song, S., Kuang, H., & Xu, C. (2017) · Food and Agricultural Immunology · doi:10.1080/09540105.2017.1297779 · Cited by 35
Perceived stress and risk of colorectal cancer in men and women: a prospective cohort study
Nielsen, N. R., Kristensen, T. S., Strandberg‐Larsen, K., Zhang, Z., Schnohr, P., & Grønbæk, M. (2007) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2007.01826.x · Cited by 26
Adaptation of DELFIATM Cortisol Kit for Determination of Salivary Cortisol Concentration
Höferl, M., Krist, S., & Buchbauer, G. (2005) · Archiv der Pharmazie · doi:10.1002/ardp.200500116 · Cited by 26
Special Focus on Nanoscale Regeneration
Dalby, M. J., & Biggs, M. J. P. (2015) · Nanomedicine · doi:10.2217/nnm.15.34 · Cited by 15
Bellando, F., Garcia-Cordero, E., Wildhaber, F., Longo, J., Guérin, H., & Ionescu, A. M. (2017) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2017.8268413 · Cited by 15
Self-citationDhull, N., Kaur, G., Gupta, V., & Tomar, M. (2018) · Vacuum · doi:10.1016/j.vacuum.2018.09.034 · Cited by 15
Khalifa, A., Abdulateef, S. A., Kabaa, E. A., Ahmed, N. M., & Sabah, F. A. (2020) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2019.104911 · Cited by 12
Ionescu, A. M., Cristoloveanu, S., Rusu, A., Chovet, A., & Hassein-Bey, A. (2002) · IEEE International SOI Conference (SOI) · doi:10.1109/soi.1993.344559 · Cited by 4
Self-citationEinstein’s Struggles with Quantum Theory: A Reappraisal
Sauer, T. (2008) · Physics Today · doi:10.1063/1.2930739 · Cited by 1
Cited by
Sorted by citations
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. F. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 752
A physicochemical-sensing electronic skin for stress response monitoring
Xu, C., Song, Y., Sempionatto, J. R., Solomon, S. A., Yu, Y., Nyein, H. Y. Y., Tay, R. Y., Li, J., Heng, W., Min, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-023-01116-6 · Cited by 422
“…activity that can affect an individual’s stress; and despite recent progress on stress hormone analysis, continuous monitoring of sweat stress hormones at physiologically relevant levels using wearable sensors has not yet been achieved because of the hormones’ extremely low concentrations 35–37 .”
BackgroundTwo-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 312
Wearable Cortisol Aptasensor for Simple and Rapid Real-Time Monitoring
An, J. E., Kim, K. H., Park, S. J., Seo, S. E., Kim, J., Ha, S., Bae, J., & Kwon, O. S. (2022) · ACS Sensors · doi:10.1021/acssensors.1c01734 · Cited by 147
Metadata
- Authors
- Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M.
- Affiliations
- University of Tehran (IR)
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Ionescu, Adrian M.
- Venue
- Communications Materials
- Published
- 2021-01-19
- Volume
- 2
- Issue
- 1
- Pages
- 10-10
- ISSN
- 2662-4443 (ISSN-L)
- PMC
- PMC7815575
- OpenAlex
- W3123066175
- Cited by
- 158
- References
- 61
- Citations by year
- 2026: 17 · 2025: 30 · 2024: 40 · 2023: 28 · 2022: 28 · 2021: 15
- FWCI
- 13.06
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Communications Materials (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- H2020 European Research Council (695459)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- extended-gate field-effect transistor, wearable biosensors, label-free detection, human sweat, circadian rhythm, Debye screening, current sensitivity, detection limit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review