The DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index.
Photovoltaic retinal prosthesis restores high-resolution responses to single-pixel stimulation in blind retinas
Open accessPublished version of a preprint
Abstract
Abstract Retinal prostheses hold the promise of restoring vision in totally blind people. However, a decade of clinical trials highlighted quantitative limitations hampering the possibility of reaching this goal. A key challenge in retinal stimulation is to independently activate retinal neurons over a large portion of the subject’s visual field. Reaching such a goal would significantly improve the perception accuracy in retinal implants’ users, along with their spatial cognition, attention, ambient mapping and interaction with the environment. Here we show a wide-field, high-density and high-resolution photovoltaic epiretinal prosthesis for artificial vision (POLYRETINA). The prosthesis embeds 10,498 physically and functionally independent photovoltaic pixels, allowing for wide retinal coverage and high-resolution stimulation. Single-pixel illumination reproducibly induced network-mediated responses from retinal ganglion cells at safe irradiance levels. Furthermore, POLYRETINA allowed response discrimination with a high spatial resolution equivalent to the pixel pitch (120 µm) thanks to the network-mediated stimulation mechanism. This approach could allow mid-peripheral artificial vision in patients with retinitis pigmentosa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“POLYRETINA reported ex-vivo a spatial resolution of 120 µm (or 20/480) equivalent to the electrode separation [132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [132]
In the citing paper
“POLYRETINA is a high-density wide-field epiretinal prosthesis containing 10 498 photovoltaic pixels distributed over an active area of approximately 43 • [38,39,131,132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [132]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
The functional diversity of retinal ganglion cells in the mouse
Baden, T., Berens, P., Franke, K., Román Rosón, M., Bethge, M., & Euler, T. (2016) · Nature · doi:10.1038/nature16468 · Cited by 999
Hamel, C. (2006) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-1-40 · Cited by 962
Perceptual grouping and attention in visual search for features and for objects.
Treisman, A. (1982) · Journal of Experimental Psychology Human Perception & Performance · doi:10.1037/0096-1523.8.2.194 · Cited by 908
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Hot exciton dissociation in polymer solar cells
Grancini, G., Maiuri, M., Fazzi, D., Petrozza, A., Egelhaaf, H., Brida, D., Cerullo, G., & Lanzani, G. (2012) · Nature Materials · doi:10.1038/nmat3502 · Cited by 659
Gargini, C., Tozzini, E. T., Mazzoni, F., & Strettoi, E. (2006) · The Journal of Comparative Neurology · doi:10.1002/cne.21144 · Cited by 496
Dendritic field size and morphology of midget and parasol ganglion cells of the human retina.
Dacey, D. M., & Petersen, M. R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.20.9666 · Cited by 487
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 484
Research works printed but not linked: 1
- Weiland, J. D. & Humayun, M. S. Retinal prosthetic systems for the treatment of blindness. Bridge 42, 51–57 (2012).
Cited by
Sorted by citations
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 157
Metaverse Wearables for Immersive Digital Healthcare: A Review
Kim, K., Yang, H., Lee, J.-H., & Lee, W. G. (2023) · Advanced Science · doi:10.1002/advs.202303234 · Cited by 110
Monolithic silicon for high spatiotemporal translational photostimulation
Li, P., Zhang, J., Hayashi, H., Yue, J., Li, W., Yang, C., Sun, C., Shi, J., Huberman-Shlaes, J., Hibino, N., et al. (2024) · Nature · doi:10.1038/s41586-024-07016-9 · Cited by 100
Materials for Implantable Surface Electrode Arrays: Current Status and Future Directions
Tringides, C. M., & Mooney, D. J. (2021) · Advanced Materials · doi:10.1002/adma.202107207 · Cited by 73
Retinal Prostheses: Engineering and Clinical Perspectives for Vision Restoration
Wu, K. Y., Mina, M., Sahyoun, J.-Y., Kalevar, A., & Tran, S. D. (2023) · Sensors · doi:10.3390/s23135782 · Cited by 75
Metadata
- Authors
- Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Ghezzi, Diego
- Venue
- Communications Materials
- Published
- 2021-03-05
- Volume
- 2
- Issue
- 1
- ISSN
- 2662-4443 (ISSN-L)
- OpenAlex
- W3134642074
- Cited by
- 110
- References
- 107
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 32 · 2023: 17 · 2022: 18 · 2021: 10
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Communications Materials (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Velux Stiftung (1102)
- Gebert Rüf Stiftung (GRS-035/17)
- Fondation Pierre Mercier pour la Science Fondation Pro Visu
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Memory and Neural Computing
- Keywords
- retinal prosthesis, epiretinal implants, retinitis pigmentosa, retinal ganglion cells, spatial resolution, artificial vision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review