The DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index.
Photovoltaic retinal prosthesis restores high-resolution responses to single-pixel stimulation in blind retinas
Open accessPublished version of a preprint
Abstract
Abstract Retinal prostheses hold the promise of restoring vision in totally blind people. However, a decade of clinical trials highlighted quantitative limitations hampering the possibility of reaching this goal. A key challenge in retinal stimulation is to independently activate retinal neurons over a large portion of the subject’s visual field. Reaching such a goal would significantly improve the perception accuracy in retinal implants’ users, along with their spatial cognition, attention, ambient mapping and interaction with the environment. Here we show a wide-field, high-density and high-resolution photovoltaic epiretinal prosthesis for artificial vision (POLYRETINA). The prosthesis embeds 10,498 physically and functionally independent photovoltaic pixels, allowing for wide retinal coverage and high-resolution stimulation. Single-pixel illumination reproducibly induced network-mediated responses from retinal ganglion cells at safe irradiance levels. Furthermore, POLYRETINA allowed response discrimination with a high spatial resolution equivalent to the pixel pitch (120 µm) thanks to the network-mediated stimulation mechanism. This approach could allow mid-peripheral artificial vision in patients with retinitis pigmentosa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“POLYRETINA reported ex-vivo a spatial resolution of 120 µm (or 20/480) equivalent to the electrode separation [132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [132]
In the citing paper
“POLYRETINA is a high-density wide-field epiretinal prosthesis containing 10 498 photovoltaic pixels distributed over an active area of approximately 43 • [38,39,131,132].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [132]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
The functional diversity of retinal ganglion cells in the mouse
Baden, T., Berens, P., Franke, K., Román Rosón, M., Bethge, M., & Euler, T. (2016) · Nature · doi:10.1038/nature16468 · Cited by 999
Hamel, C. (2006) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-1-40 · Cited by 962
Perceptual grouping and attention in visual search for features and for objects.
Treisman, A. (1982) · Journal of Experimental Psychology Human Perception & Performance · doi:10.1037/0096-1523.8.2.194 · Cited by 908
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Hot exciton dissociation in polymer solar cells
Grancini, G., Maiuri, M., Fazzi, D., Petrozza, A., Egelhaaf, H., Brida, D., Cerullo, G., & Lanzani, G. (2012) · Nature Materials · doi:10.1038/nmat3502 · Cited by 659
Gargini, C., Tozzini, E. T., Mazzoni, F., & Strettoi, E. (2006) · The Journal of Comparative Neurology · doi:10.1002/cne.21144 · Cited by 496
Dendritic field size and morphology of midget and parasol ganglion cells of the human retina.
Dacey, D. M., & Petersen, M. R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.20.9666 · Cited by 487
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 484
Research works printed but not linked: 1
- Weiland, J. D. & Humayun, M. S. Retinal prosthetic systems for the treatment of blindness. Bridge 42, 51–57 (2012).
Cited by
Sorted by citations
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 157
Metaverse Wearables for Immersive Digital Healthcare: A Review
Kim, K., Yang, H., Lee, J.-H., & Lee, W. G. (2023) · Advanced Science · doi:10.1002/advs.202303234 · Cited by 110
Monolithic silicon for high spatiotemporal translational photostimulation
Li, P., Zhang, J., Hayashi, H., Yue, J., Li, W., Yang, C., Sun, C., Shi, J., Huberman-Shlaes, J., Hibino, N., et al. (2024) · Nature · doi:10.1038/s41586-024-07016-9 · Cited by 100
Materials for Implantable Surface Electrode Arrays: Current Status and Future Directions
Tringides, C. M., & Mooney, D. J. (2021) · Advanced Materials · doi:10.1002/adma.202107207 · Cited by 73
Retinal Prostheses: Engineering and Clinical Perspectives for Vision Restoration
Wu, K. Y., Mina, M., Sahyoun, J.-Y., Kalevar, A., & Tran, S. D. (2023) · Sensors · doi:10.3390/s23135782 · Cited by 75
POLYRETINA restores light responses in vivo in blind Göttingen minipigs
Vagni, P., Airaghi Leccardi, M. J. I., Vila, C.-H., Zollinger, E. G., Sherafatipour, G., Wolfensberger, T. J., & Ghezzi, D. (2022) · Nature Communications · doi:10.1038/s41467-022-31180-z · Cited by 62
Self-citationHan, M., Yıldız, E., Kaleli, H. N., Karaz, S., Eren, G. O., Dogru-Yuksel, I. B., Şenses, E., Şahin, A., & Nizamoğlu, S. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202102160 · Cited by 59
Karatum, O., Gwak, M.-J., Hyun, J., Önal, A., Koirala, G. R., Kim, T., & Nizamoğlu, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs01020h · Cited by 54
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Self-citationShi, J., Li, P., Kim, S., & Tian, B. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00285-7 · Cited by 45
Joseph, E., Ciocca, M., Wu, H., Marcozzi, S., Ucci, M. A., Keremane, K. S., Zheng, L., Poudel, B., Wu, C., Camaioni, A., et al. (2024) · npj Biosensing · doi:10.1038/s44328-024-00015-w · Cited by 41
Organic semiconductors for light-mediated neuromodulation
Medagoda, D. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00217-z · Cited by 39
Self-citationRetinal Organoids and Retinal Prostheses: An Overview
Bellapianta, A., Cetkovic, A., Bolz, M., & Salti, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23062922 · Cited by 40
Flexible optoelectronic sensors: status and prospects
Wang, Z., & Shen, G. (2023) · Materials Chemistry Frontiers · doi:10.1039/d2qm01319c · Cited by 34
Lu, G., Gong, C., Sun, Y., Qian, X., Nair, D. S. R., Li, R., Zeng, Y., Ji, J., Zhang, J., Kang, H., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48683-6 · Cited by 32
Advanced Sensory Hardware for Intelligent Eye‐Machine Interfacing: from Wearables to Bionics
Wang, Z., Li, S., & Shen, G. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202503519 · Cited by 31
Correlated Activity in the Degenerate Retina Inhibits Focal Response to Electrical Stimulation
Ahn, J., Cha, S., Choi, K.-E., Kim, S., Yoo, Y., & Goo, Y. S. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.889663 · Cited by 29
Electronic Retinal ProsthesesPreprint
Palanker, D. (2020) · Cold Spring Harbor Perspectives in Medicine · doi:10.1016/b978-0-12-809324-5.24123-0 · Cited by 32
Coghi, P. S., & Coluccini, C. (2024) · Polymers · doi:10.3390/polym16101407 · Cited by 25
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcd6f · Cited by 28
Self-citationExploring Present and Future Directions in Nano-Enhanced Optoelectronic Neuromodulation
Yang, C., Cheng, Z., Li, P., & Tian, B. (2024) · Accounts of Chemical Research · doi:10.1021/acs.accounts.4c00086 · Cited by 25
Physical mechanisms of emerging neuromodulation modalities
Karatum, O., Han, M., Erdoğan, E. T., Karamürsel, S., & Nizamoğlu, S. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd870 · Cited by 20
Bioinspired and biointegrated vision for artificial sight convergence
Yang, Y., Wang, Y., Zhu, C., Xie, Z., Qin, Z., Wang, Z., & Chai, Y. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00324-3 · Cited by 20
Immersive interfaces for clinical applications: current status and future perspective
Chenais, N. A. L., & Görgen, A. (2024) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2024.1362444 · Cited by 23
Self-citationChen, K.-S., Chan, H.-C., & Chan, C.-M. (2025) · Journal of Biological Engineering · doi:10.1186/s13036-025-00548-2 · Cited by 19
Nanoparticle-based optical interfaces for retinal neuromodulation: a review
Stoddart, P. R., Begeng, J. M., Tong, W., Ibbotson, M. R., & Kameneva, T. (2024) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2024.1360870 · Cited by 18
Adaptive Interfacial Materials and Implants for Visual Restoration
Zhu, X., Wang, F., Zhao, Q., & Du, X. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202314575 · Cited by 17
Nie, J., Eom, K., AlGhosain, H. M., Neifert, A. R., Cherian, A., Gerbaka, G. M., Ma, K. Y., Liu, T., & Lee, J. (2025) · ACS Nano · doi:10.1021/acsnano.4c14061 · Cited by 18
A review: flexible devices for nerve stimulation
Liu, Z.-Q., Yu, X.-Y., Huang, J., Wu, X.-Y., Wang, Z.-Y., & Zhu, B. (2024) · Soft Science · doi:10.20517/ss.2023.36 · Cited by 15
Yuhong, Z., Liu, X., Ma, J., Wang, Z., Jiang, H., Sun, C., Jeong, D., Guan, H., & Chu, B. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c12460 · Cited by 15
Yang, J., Chen, C., Yu, Z.-Y., Chung, J. H.-Y., Liu, X., Wu, C., & Chen, G. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100253 · Cited by 15
Ciocca, M., Marcozzi, S., Mariani, P., Lacconi, V., Carlo, A. D., Cinà, L., Rosato‐Siri, M. D., Zanon, A., Cattelan, G., Avancini, E., et al. (2023) · Advanced NanoBiomed Research · doi:10.1002/anbr.202200127 · Cited by 14
Balamur, R., Oh, J. T., Karatum, O., Wang, Y., Önal, A., Kaleli, H. N., Pehlivan, Ç., Şahin, A., Hasanreisoğlu, M., Konstantatos, G., et al. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c01964 · Cited by 14
Schaffrath, K., Lohmann, T., Seifert, J., Ingensiep, C., Raffelberg, P., Waschkowski, F., Viga, R., Kokozinski, R., Mokwa, W., Johnen, S., et al. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00938-9 · Cited by 15
Agadagba, S. K., Eldaly, A. B. M., & Chan, L. L. H. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.785199 · Cited by 14
Questions about the role of P3HT nanoparticles in retinal stimulation
Palanker, D., Głowacki, E. D., & Ghezzi, D. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-01044-6 · Cited by 14
Self-citationSherwood, C. P., Crovador, R., Posar, J. A., Brichta, N. M., Simunovic, M. P., Louie, F., Dastoor, P. C., Brichta, A. M., Cairney, J. M., Holmes, N. P., et al. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202229 · Cited by 13
Therapeutic landscape for inherited ocular diseases: current and emerging therapies
Chan, H. W., Oh, J., & Leroy, B. P. (2023) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2022-179 · Cited by 13
Borda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11
Self-citationThorn, J. T., Chenais, N. A. L., Hinrichs, S., Chatelain, M., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5a5c · Cited by 11
Self-citationSemantic translation of face image with limited pixels for simulated prosthetic vision
Xia, X., He, X., Lu, F., Pan, X., Li, N., Zhang, J., Pang, X., Yu, F., & Ding, N. (2022) · Information Sciences · doi:10.1016/j.ins.2022.07.094 · Cited by 12
Gaillet, V., Borda, E., Zollinger, E. G., & Ghezzi, D. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf523 · Cited by 10
Self-citationThe mechanism of human color vision and potential implanted devices for artificial color vision
Zhang, B., Zhang, R., Zhao, J., Yang, J., & Xu, S. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1408087 · Cited by 12
Neuroprotection, Neuroenhancement, and Neuroregeneration of the Retina and Optic Nerve
Johnson, T. V., Polo, A. D., Sahel, J., & Schuman, J. S. (2022) · Ophthalmology Science · doi:10.1016/j.xops.2022.100216 · Cited by 10
The role of the visual field size in artificial vision
Ghezzi, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acc7cd · Cited by 13
Self-citationOptogenetic activation of visual thalamus generates artificial visual percepts
Wang, J., Azimi, H., Zhao, Y., Kaeser, M., Sánchez, P. V., Vázquez‐Guardado, A., Rogers, J. A., Harvey, M., & Rainer, G. (2023) · eLife · doi:10.7554/elife.90431 · Cited by 9
MnO2 Nanoflower Integrated Optoelectronic Biointerfaces for Photostimulation of Neurons
Kaya, L., Karatum, O., Balamur, R., Kaleli, H. N., Önal, A., Vanalakar, S. A., Hasanreisoğlu, M., & Nizamoğlu, S. (2023) · Advanced Science · doi:10.1002/advs.202301854 · Cited by 10
Jo, B., Seo, K., Park, K., Jeong, C., Bathalavaram, P., Lee, M., Ramu, S., Hahm, M. G., & Kim, Y. L. (2024) · Frontiers in Materials · doi:10.3389/fmats.2024.1354522 · Cited by 9
Explainable machine learning predictions of perceptual sensitivity for retinal prostheses
Pogoncheff, G., Hu, Z., Rokem, A., & Beyeler, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad310f · Cited by 10
An actor-model framework for visual sensory encoding
Leong, F., Rahmani, B., Psaltis, D., Moser, C., & Ghezzi, D. (2024) · Nature Communications · doi:10.1038/s41467-024-45105-5 · Cited by 8
Self-citationOh, Y., Hong, J., & Kim, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0305132 · Cited by 8
Joseph, E., Leonardi, C., Nunzio, L. D., Ucci, M. A., Ciocca, M., Mariani, P., Podapangi, S. K., Castriotta, L. A., Vesce, L., Medaglia, P. G., et al. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501461 · Cited by 7
Double‐Sided, Thin‐Film Microelectrode Array with Hemispheric Electrodes for Subretinal Stimulation
Kim, N., Hong, Y., Cha, S., Kang, Y. N., Seo, H. W., Moon, H., Ahn, J., Intisar, A., Kim, M. S., Kim, S., et al. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202302155 · Cited by 8
Perspectives on non-genetic optoelectronic modulation biointerfaces for advancing healthcare
Majmudar, A., Kim, S., Li, P., & Tian, B. (2024) · Med-X · doi:10.1007/s44258-024-00030-6 · Cited by 7
Honeycomb-type retinal device using chemically derived iridium oxide biointerfaces
Tso, K.-C., Fukunari, Y., Hagita, M., Haruta, M., Takehara, H., Tashiro, H., Sasagawa, K., Wu, P., & Ohta, J. (2021) · AIP Advances · doi:10.1063/5.0058457 · Cited by 7
Electrophysiological investigation of intact retina with soft printed organic neural interface
Vėbraitė, I., David‐Pur, M., Rand, D., Głowacki, E. D., & Hanein, Y. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac36ab · Cited by 7
Controlled assembly of retinal cells on fractal and Euclidean electrodes
Moslehi, S., Rowland, C., Smith, J. H., Watterson, W. J., Miller, D., Niell, C. M., Alemán, B., Perez, M.-T., & Taylor, R. P. (2022) · PLoS ONE · doi:10.1371/journal.pone.0265685 · Cited by 7
Explainable Machine Learning Predictions of Perceptual Sensitivity for Retinal Prostheses
Pogoncheff, G., Hu, Z., Rokem, A., & Beyeler, M. (2023) · doi:10.1101/2023.02.09.23285633 · Cited by 9
“With Argus II consisting of 60 electrodes, this procedure is time-consuming at best, but will quickly become infeasible as new devices are being developed that feature hundreds or even thousands of electrodes [6], [7].”
Developments in the design and microfabrication of photovoltaic retinal implants
Kusumanchi, P., Keller, S. S., & Davidsen, R. S. (2024) · Micro and Nano Engineering · doi:10.1016/j.mne.2024.100289 · Cited by 6
In the Eye of the Storm: Bi-Directional Electrophysiological Investigation of the Intact Retina
Vėbraitė, I., & Hanein, Y. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.829323 · Cited by 5
Deepak, C. S., Krishnan, A., & Narayan, K. S. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6f80 · Cited by 6
Moslehi, S., Rowland, C., Smith, J. H., Griffiths, W., Watterson, W. J., Niell, C. M., Alemán, B., Perez, M.-T., & Taylor, R. P. (2022) · Scientific Reports · doi:10.1038/s41598-022-21742-y · Cited by 6
Cojocaru, A.-E., Corna, A., Reh, M., & Zeck, G. M. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1033738 · Cited by 5
Information Transmission through Biotic–Abiotic Interfaces to Restore or Enhance Human Function
Kelly, A. R., & Glover, D. J. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00435 · Cited by 5
Near‐Infrared Organic Photovoltaic Electrodes for Subretinal Neurostimulation
Corna, A., Gugujonović, K., Schiek, M., Bellapianta, A., Werginz, P., Ziller, A., Scharber, M. C., Salti, A., Bolz, M., Irimia‐Vladu, M., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202515327 · Cited by 6
Photovoltaic, wireless wide‐field epiretinal prosthesis to treat retinitis pigmentosa
Schulz, A., Knoll, T., Jaeger, T., Harzic, R. L., Stracke, F., Wien, S., Olsommer, Y., Meiser, I., Wagner, S., Rammensee, M., et al. (2024) · Acta Ophthalmologica · doi:10.1111/aos.16733 · Cited by 4
Dagar, J., & Brown, T. M. (2022) · Nanotechnology · doi:10.1088/1361-6528/ac7883 · Cited by 4
Gustatory interface for operative assessment and taste decoding in patients with tongue cancer
Wang, X., Bai, G., Liang, J., Xie, Q., Chen, Z., Zhou, E., Li, M., Wei, X., Sun, L., Zhang, Z., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-53379-y · Cited by 5
Polz, M., Binter, K., Yallum, K. M., Rath, T., Nowakowska, M., Schimpel, C., Sommer, G., Ghaffari‐Tabrizi‐Wizsy, N., Banerji, N., Trimmel, G., et al. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202400899 · Cited by 4
An implantable epiretinal device for near-infrared light perception
Chung, W. G., Jeong, I., Lee, E., Cui, G., Jeong, H., Choi, M. S., Lee, S., an, S. E. M., Kim, E., Kim, S., et al. (2026) · Nature Electronics · doi:10.1038/s41928-026-01601-8 · Cited by 3
Engineering Materials for Neurotechnology
Ghezzi, D. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202201412 · Cited by 2
Self-citationRahmani, A., & Eom, K. (2024) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2024.1385567 · Cited by 3
A Functional BCI Model by the P2731 working group: Physiology
Hossaini, A., Valeriani, D., Nam, C. S., Ferrante, R., & Mahmud, M. (2021) · Brain-Computer Interfaces · doi:10.1080/2326263x.2021.1968665 · Cited by 3
Morphological Factors that Underlie Neural Sensitivity to Stimulation in the Retina
Raghuram, V., Werginz, P., Fried, S. I., & Timko, B. P. (2021) · Advanced NanoBiomed Research · doi:10.1002/anbr.202100069 · Cited by 3
A computational model to design wide field-of-view optic nerve neuroprostheses
Romeni, S., Luca, D. D., Pierantoni, L., Toni, L., Marino, G., Moccia, S., & Micera, S. (2024) · iScience · doi:10.1016/j.isci.2024.111321 · Cited by 2
A Cell-Type Selective Stimulation and Recording System for Retinal Ganglion Cells
Löhler, P., Albert, A., Erbslöh, A., Nruthyathi, Müller, F. W., & Seidl, K. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3342465 · Cited by 2
Transparent and conformal microcoil arrays for spatially selective neuronal activation
Raghuram, V., Datye, A. D., Fried, S. I., & Timko, B. P. (2024) · Device · doi:10.1016/j.device.2024.100290 · Cited by 4
Neurostimulation in Neuro-Ophthalmology: Mechanisms and Therapeutic Potential
Shaheen, N., Khaled, M. B., Seo, S., Bezchlibnyk, Y. B., Flouty, O. E., & Bharmauria, V. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.115105 · Cited by 4
Relating the Morphology of Bipolar Neurons to Fractal Dimension
Brouse, B., Rowland, C., & Taylor, R. P. (2024) · Fractal and Fractional · doi:10.3390/fractalfract9010009 · Cited by 2
Lemaire, W., Benhouria, M., Koua, K., Tong, W., Martin-Hardy, G., Stamp, M. E. M., Ganesan, K., Gauthier, L.-P., Besrour, M., Ahnood, A., et al. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3516492 · Cited by 2
Silicon Solar Cell-Integrated Flexible Retinal Prosthesis for Artificial Vision
Kim, C., Chung, S.-H., Kim, Y.-J., Roh, H., Lee, S.-K., Kim, Y., Lee, H., Park, J., Kang, M. G., & Im, M. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917587 · Cited by 1
Implantable Nongenetic Optoelectronic Biointerfaces for Neuromodulation
Ye, J., Huang, J., Nie, W., Xu, J., Sheng, X., & Wang, H. (2025) · Advanced Photonics Research · doi:10.1002/adpr.202500176 · Cited by 2
Geometrical‐ and Substrate‐Dependent Photo Response of Thin‐Film Silicon‐Based Biointerfaces
Li, L., Zhang, Y., Gao, Y., Wang, Y., Wang, S., Gao, X., Chen, K., Yin, L., Sheng, X., & Yao, D. (2025) · Small Methods · doi:10.1002/smtd.202501228 · Cited by 1
Antibody-Modified Photovoltaic Biointerface for Neural Stimulation
Ou, W., Wen, N., Deng, H., Jiang, Q., & Liu, D. (2025) · ACS Nano · doi:10.1021/acsnano.5c12629 · Cited by 1
Hadji-Pulja, V., & Hulot, G. (2025) · doi:10.57088/978-3-7329-8750-4_12 · Cited by 1
Sensitive Imaging Using Graphene Photodetector Arrays with Passive Crosstalk Reduction Techniques
Homs, M., Nashashibi, S., Himstedt, E., Koepfli, S. M., Keller, K., Rieben, D., Fedoryshyn, Y. M., Haq, W., Zrenner, E., & Leuthold, J. (2025) · OSA Advanced Photonics Congress · doi:10.1364/noma.2025.now3c.2 · Cited by 1
Nanomaterial based photoacoustic interface for non-genetic neuromodulation
Li, D., Chen, G., Li, Y., Zheng, N., Du, Z., & Yang, C. (2026) · Nano Futures · doi:10.1088/2399-1984/ae44dc · Cited by 1
Guan, B., de la Perrelle, J. M., Zhang, J., Tunnadine, R. J., Malik, M., Li, R., Lim, R., & Griffith, M. J. (2026) · Biofabrication · doi:10.1088/1758-5090/ae6370 · Cited by 1
Self-organized nanoplasmonic artificial leaf for hot-carrier bioelectronic interfaces
Li, P., Liufu, M., Johnston, C. R., Pyo, Y., Zheng, Y., Yang, G., Kamath, A., Li, R., Liu, Y., Bassetto, C. A. Z., et al. (2026) · Nature Photonics · doi:10.1038/s41566-026-01949-5 · Cited by 1
Does Charge Balancing Ensure the Safety of the Electrical Stimulation and Is It Power Efficientƒ
Ranjandish, R., & Kim, G. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340438 · Cited by 1
Moslehi, S., Rowland, C., Smith, J. H., Watterson, W. J., Griffiths, W., Montgomery, R. D., Philliber, S., Marlow, C. A., Perez, M. T., & Taylor, R. P. (2024) · Advances in neurobiology · doi:10.1007/978-3-031-47606-8_43 · Cited by 1
Evolution of Retinal Neuron Fractality When Interfacing with Carbon Nanotube Electrodes
Dillon, A. P., Moslehi, S., Brouse, B., Keremane, S., Philliber, S., Griffiths, W., Rowland, C., Smith, J. H., & Taylor, R. P. (2024) · Bioengineering · doi:10.3390/bioengineering11080823 · Cited by 1
Hinrichs, S., Placidet, L., Duret, A., Authié, C., Arleo, A., & Ghezzi, D. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8b6f · Cited by 1
Self-citationBorda, E., Gaillet, V., Leccardi, M. J. I. A., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.03.21.485100
Self-citationDesign and Implementation of Artificial Retinal Photoreceptors
Tripathi, M., & Yaduvanshi, R. S. (2022) · Asian Conference on Innovation in Technology (ASIANCON) · doi:10.1109/asiancon55314.2022.9909222
Löhler, P., Pickhinke, A., Erbslöh, A., & Seidl, K. (2023) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas57931.2023.10198191
Designing immersive interfaces for clinical applicationsPreprint
Chenais, N. A. L., & Görgen, A. (2024) · doi:10.31219/osf.io/gvs9d
Self-citationHinrichs, S., Tisserand, Y., Scialom, E., & Ghezzi, D. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.03.27.645647
Self-citationDevelopment and Evaluation of Multi-Module Retinal Devices for Artificial Vision Applications
Tso, K.-C., Sunaga, Y., Nakanishi, Y., Terasawa, Y., Haruta, M., Sasagawa, K., & Ohta, J. (2025) · Micromachines · doi:10.3390/mi16050580
Metadata
- Authors
- Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Ghezzi, Diego
- Venue
- Communications Materials
- Published
- 2021-03-05
- Volume
- 2
- Issue
- 1
- ISSN
- 2662-4443 (ISSN-L)
- OpenAlex
- W3134642074
- Cited by
- 110
- References
- 107
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 32 · 2023: 17 · 2022: 18 · 2021: 10
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Communications Materials (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Velux Stiftung (1102)
- Gebert Rüf Stiftung (GRS-035/17)
- Fondation Pierre Mercier pour la Science Fondation Pro Visu
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Memory and Neural Computing
- Keywords
- retinal prosthesis, epiretinal implants, retinitis pigmentosa, retinal ganglion cells, spatial resolution, artificial vision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review