The density difference between tissue and neural probes is a key factor for glial scarring
Open accessAbstract
A key to successful chronic neural interfacing is to achieve minimal glial scarring surrounding the implants, as the astrocytes and microglia may functionally insulate the interface. A possible explanation for the development of these reactions is mechanical forces arising between the implants and the brain. Here, we show that the difference between the density of neural probes and that of the tissue, and the resulting inertial forces, are key factors for the development of the glial scar. Two probes of similar size, shape, surface structure and elastic modulus but differing greatly in density were implanted into the rat brain. After six weeks, significantly lower astrocytic and microglial reactions were found surrounding the low-density probes, approaching no reaction at all. This provides a major key to design fully biocompatible neural interfaces and a new platform for in vivo assays of tissue reactions to probes with differing materials, surface structures, and shapes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The ideal density for an implant is close to 1 g/cm3 to minimize glial scarring and optimize functionality.
“The ideal density for an implant is close to 1 g/cm3 to minimize glial scarring and optimize functionality (Lind et al., 2013), though density requirements can vary based on brain region, patient, and implant material.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Lind et al., 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · see citing works
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · see citing works
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160 · see citing works
Flagged first, then by citations
Research works printed but not linked: 29
- Kipke D. R. et al. Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities. J Neurosci 28, 11830– 11838 (2008). 19005048 PMC3844837
- Schouenborg J. Biocompatible multichannel electrodes for long-term neurophysiological studies and clinical therapy–novel concepts and design. Prog Brain Res 194, 61– 70, 10.1016/B978-0-444-53815-4.00017-0 (2011). 21867794 · DOI
- Polikov V. S., Tresco P. A. & Reichert W. M. Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods 148, 1– 18 (2005). 16198003
- Rousche P. J. & Normann R. A. Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. J Neurosci Methods 82, 1– 15 (1998). 10223510
- Williams J. C., Rennaker R. L. & Kipke D. R. Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. Brain Res Brain Res Protoc 4, 303– 313 (1999). 10592339
- McConnell G. C., Butera R. J. & Bellamkonda R. V. Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes. J Neural Eng 6, 055005 (2009). 19721187
- Szarowski D. H. et al. Brain responses to micro-machined silicon devices. Brain Res 983, 23– 35 (2003). 12914963
- Williams J. C., Hippensteel J. A., Dilgen J., Shain W. & Kipke D. R. Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants. Journal of Neural Engineering 4, 410– 423, 10.1088/1741-2560/4/4/007 (2007). 18057508 · DOI
- Edell D. J., Toi V. V., McNeil V. M. & Clark L. D. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE transactions on bio-medical engineering 39, 635– 643, 10.1109/10.141202 (1992). 1601445 · DOI
- McConnell G. C. et al. Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration. J Neural Eng 6, 56003 (2009). 19700815
- Gilletti A. & Muthuswamy J. Brain micromotion around implants in the rodent somatosensory cortex. Journal of Neural Engineering 3, 189– 195, 10.1088/1741-2560/3/3/001 (2006). 16921202 · DOI
- Biran R., Martin D. C. & Tresco P. A. The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. J Biomed Mater Res A 82, 169– 178 (2007). 17266019
- Kim Y. T., Hitchcock R. W., Bridge M. J. & Tresco P. A. Chronic response of adult rat brain tissue to implants anchored to the skull. Biomaterials 25, 2229– 2237 (2004). 14741588
- Thelin J. et al. Implant size and fixation mode strongly influence tissue reactions in the CNS. PLoS One 6, e16267, 10.1371/journal.pone.0016267 (2011). 21298109 PMC3027655 · DOI
- Freire M. A. et al. Comprehensive analysis of tissue preservation and recording quality from chronic multielectrode implants. PLoS One 6, e27554, 10.1371/journal.pone.0027554 (2011). 22096594 PMC3212580 · DOI
- Williams D. F. The Williams dictionary of biomaterials. (Liverpool University Press, 1999).
- Lind G., Gallentoft L., Danielsen N., Schouenborg J. & Pettersson L. M. Multiple implants do not aggravate the tissue reaction in rat brain. PLoS One 7, e47509, 10.1371/journal.pone.0047509 (2012). 23091629 PMC3472973 · DOI
- Lind G., Linsmeier C. E., Thelin J. & Schouenborg J. Gelatine-embedded electrodes–a novel biocompatible vehicle allowing implantation of highly flexible microelectrodes. Journal of Neural Engineering 7, 046005, 10.1088/1741-2560/7/4/046005 (2010). 20551508 · DOI
- Turner J. N. et al. Cerebral Astrocyte Response to Micromachined Silicon Implants. Experimental Neurology 156, 33– 49 (1999). 10192775
- Eriksson Linsmeier C. et al. Nanowire biocompatibility in the brain–looking for a needle in a 3D stack. Nano Lett 9, 4184– 4190 (2009). 19845389
- Grill W. M., Norman S. E. & Bellamkonda R. V. Implanted neural interfaces: biochallenges and engineered solutions. Annu Rev Biomed Eng 11, 1– 24 (2009). 19400710
- He W., McConnell G. C. & Bellamkonda R. V. Journal of Neural Engineering Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays. 3, 316– 326, 10.1088/1741-2560/3/4/009 (2006). 17124336 · DOI · Paper page
- McConnell G. C., Schneider T. M., Owens D. J. & Bellamkonda R. V. Extraction force and cortical tissue reaction of silicon microelectrode arrays implanted in the rat brain. IEEE transactions on bio-medical engineering 54, 1097– 1107, 10.1109/TBME.2007.895373 (2007). 17554828 · DOI
- Seymour J. P. & Kipke D. R. Neural probe design for reduced tissue encapsulation in CNS. Biomaterials 28, 3594– 3607, 10.1016/j.biomaterials.2007.03.024 (2007). 17517431 · DOI · Paper page
- Stice P., Gilletti A., Panitch A. & Muthuswamy J. Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex. Journal of Neural Engineering 4, 42– 53 (2007). 17409479
- Beckmann F. et al. Three-Dimensional Imaging of Nerve Tissue by X-Ray Phase-Contrast Microtomography. Biophysical Journal 76, 98– 102, http://dx.doi.org/10.1016/S0006-3495(99)77181-X (1999). 9876126 PMC1302503 · DOI
- Wanner I. B. An in vitro trauma model to study rodent and human astrocyte reactivity. Methods Mol Biol 814, 189– 219, 10.1007/978-1-61779-452-0_14 (2012). 22144309 · DOI
- Vetter R. J., Williams J. C., Hetke J. F., Nunamaker E. A. & Kipke D. R. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex. IEEE transactions on bio-medical engineering 51, 896– 904, 10.1109/TBME.2004.826680 (2004). 15188856 · DOI
- Kozai T. D. et al. Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. Nat Mater 11, 1065– 1073, 10.1038/nmat3468 (2012). 23142839 PMC3524530 · DOI · Paper page
Cited by
Sorted by citations
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668 · see citing works
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655 · see citing works
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227 · see citing works
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205 · see citing works
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158 · see citing works
High Density, Double-Sided, Flexible Optoelectronic Neural Probes With Embedded μLEDs
Reddy, J. W., Kimukin, I., Stewart, L. T., Ahmed, Z., Barth, A. L., Towe, E., & Chamanzar, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00745 · Cited by 55 · see citing works
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21 · see citing works
- Authors
- Lind, G., Linsmeier, C. E., & Schouenborg, J.
- Affiliations
- Lund University (SE)
- Corresponding author
- Lind, Gustav
- ORCID
- Schouenborg, Jens
- Venue
- Scientific Reports
- Published
- 2013-10-15
- Volume
- 3
- Issue
- 1
- Pages
- 2942-2942
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC3796741
- OpenAlex
- W2122820460
- Cited by
- 102
- References
- 4
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 9 · 2023: 5 · 2022: 4 · 2021: 13 · 2020: 8 · 2019: 12 · 2018: 4 · 2017: 11 · 2016: 9 · 2015: 11 · 2014: 6
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Scientific Reports (publishedVersion, cc-by-nc-sa)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-sa)
- PubMed Central (publishedVersion, cc-by-nc-sa)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion, other-oa)
- Funders
- Lunds Universitet
- Knut och Alice Wallenbergs Stiftelse (KAW 2004.0119, 2004.0119)
- Vetenskapsrådet
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- glial scar, neural probes, probe density, inertial forces, astrocytes, microglia, biocompatibility
- MeSH terms
- Animals, Cicatrix, Female, Nerve Tissue Proteins, Neuroglia, Implants, Experimental, Antigens, Nuclear, Rats, Ectodysplasins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review