Oxygen-induced cell migration and on-line monitoring biomarkers modulation of cervical cancers on a microfluidic system
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this work, we report an integrated microfluidic device for cell co-culture under different concentrations of oxygen, in which the secreted protein VEGF 165 was on-line qualitatively and semi-quantitatively analyzed by functional nucleic acid, hemin, ABTS and peroxide system. This microfluidic platform allowed investigation of various oxygen and distances effect on cell-to-cell communication. Besides, the microfluidic device was used for real-time analysis of VEGF 165 protein by aptamer-functionalized microchannels. Under 5% O 2 condition, we found that the migration of CaSki cells was faster than the migration of human umbilical vein endothelial cells. However, the migration of CaSki cells was slower than the migration of HUVECs under 15% O 2 condition. Moreover, the shorter intercellular distances, the quicker cells migration. Furthermore, HIF-1α and VEGF 165 genes, ROS were analyzed and the results would provide new perspectives for the diagnosis and medical treatment of cervical cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Most of them control the oxygen levels in culture chambers and can be categorized into three groups; introducing oxygen scavenging chemicals [210, 211], gas supply channels adjacent to the cell chamber [212] and oxygen impermeable materials [213, 214].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [212]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Selective killing of cancer cells by a small molecule targeting the stress response to ROS
Raj, L., Ide, T., Gurkar, A. U., Foley, M., Schenone, M., Li, X., Tolliday, N. J., Golub, T. R., Carr, S. A., Shamji, A. F., et al. (2011) · Nature · doi:10.1038/nature10167 · Cited by 1,030
RetractedReactive oxygen species (ROS) homeostasis and redox regulation in cellular signaling
Ray, P. D., Huang, B.-W., & Tsuji, Y. (2012) · Cellular Signalling · doi:10.1016/j.cellsig.2012.01.008 · Cited by 4,373
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Hypoxia-inducible factors in physiology and medicine
Semenza, G. L. (2012) · Cell · doi:10.1016/j.cell.2012.01.021 · Cited by 3,645
Reactive oxygen species, cellular redox systems, and apoptosis
Circu, M. L., & Aw, T. Y. (2010) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.12.022 · Cited by 3,340
Modes of resistance to anti-angiogenic therapy
Bergers, G., & Hanahan, D. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2442 · Cited by 2,953
Regulation of angiogenesis by hypoxia: role of the HIF system
Pugh, C. W., & Ratcliffe, P. J. (2003) · Nature Medicine · doi:10.1038/nm0603-677 · Cited by 2,520
HIF-1 mediates adaptation to hypoxia by actively downregulating mitochondrial oxygen consumption
Papandreou, I., Cairns, R. A., Fontana, L., Lim, A. L., & Denko, N. C. (2006) · Cell Metabolism · doi:10.1016/j.cmet.2006.01.012 · Cited by 2,267
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Holmquist-Mengelbier, L., Fredlund, E., Löfstedt, T., Noguera, R., Navarro, S., Nilsson, H., Pietras, A., Vallon-Christersson, J., Borg, Å., Gradin, K., et al. (2006) · Cancer Cell · doi:10.1016/j.ccr.2006.08.026 · Cited by 735
Xia, C., Meng, Q., Liu, L.-Z., Rojanasakul, Y., Wang, X.-R., & Jiang, B.-H. (2007) · Cancer Research · doi:10.1158/0008-5472.can-07-0783 · Cited by 507
VEGF and angiopoietin signaling in tumor angiogenesis and metastasis
Saharinen, P., Eklund, L., Pulkki, K., Bono, P., & Alitalo, K. (2011) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2011.01.015 · Cited by 478
Catalytic Beacons for the Detection of DNA and Telomerase Activity
Xiao, Y., Pavlov, V., Niazov, T., Dishon, A., Kotler, M., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031875r · Cited by 404
Reactive oxygen species in tumor metastasis
Nishikawa, M. (2008) · Cancer Letters · doi:10.1016/j.canlet.2008.02.031 · Cited by 398
Catalytic Beacons for the Detection of DNA and Telomerase Activity
Xiao, Y., Pavlov, V., Niazov, T., Dishon, A., Kotler, M., & Willner, I. (2006) · NATO Security through Science Series · doi:10.1007/1-4020-3384-2_15 · Cited by 376
Travascio, P., Witting, P. K., Mauk, A. G., & Sen, D. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0023534 · Cited by 351
Lee, J.-H., Canny, M. D., De Erkenez, A., Krilleke, D., Ng, Y.-S., Shima, D. T., Pardi, A., & Jucker, F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509069102 · Cited by 242
Lee, S. L. C., Rouhi, P., Jensen, L. D., Zhang, D., Ji, H., Hauptmann, G., Ingham, P., & Cao, Y. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909228106 · Cited by 240
Bracken, C. P., Fedele, A. O., Linke, S., Balrak, W., Lisy, K., Whitelaw, M. L., & Peet, D. J. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m600288200 · Cited by 222
Optical Aptasensors for the Analysis of the Vascular Endothelial Growth Factor (VEGF)
Freeman, R., Girsh, J., Fang-ju Jou, A., Ho, J.-A. A., Hug, T., Dernedde, J., & Willner, I. (2012) · Analytical Chemistry · doi:10.1021/ac3011473 · Cited by 186
Oladipupo, S., Hu, S., Kovalski, J., Yao, J., Santeford, A., Sohn, R. E., Shohet, R., Maslov, K., Wang, L. V., & Arbeit, J. M. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101321108 · Cited by 183
Liu, T., Lin, B., & Qin, J. (2010) · Lab on a Chip · doi:10.1039/c000022a · Cited by 162
Probing High Affinity Sequences of DNA Aptamer against VEGF165
Kaur, H., & Yung, L. L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031196 · Cited by 153
Funamoto, K., Zervantonakis, I. K., Liu, Y., Ochs, C. J., Kim, C., & Kamm, R. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40306d · Cited by 151
A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime
Zhang, Q., Liu, T., & Qin, J. (2012) · Lab on a Chip · doi:10.1039/c2lc00030j · Cited by 151
Raja, R., Kale, S., Thorat, D., Soundararajan, G., Lohite, K., Mane, A. D., Karnik, S. V., & Kundu, G. C. (2013) · Oncogene · doi:10.1038/onc.2013.171 · Cited by 149
Fabrication of miniature Clark oxygen sensor integrated with microstructure
Wu, C.-C., Yasukawa, T., Shiku, H., & Matsue, T. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.02.014 · Cited by 107
Dissolved oxygen concentration in culture medium: assumptions and pitfalls
Newby, D., Marks, L., & Lyall, F. (2004) · Placenta · doi:10.1016/j.placenta.2004.07.002 · Cited by 89
Ren, L., Liu, W., Wang, Y., Wang, J.-C., Tu, Q., Xu, J., Liu, R., Shen, S.-F., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac3025812 · Cited by 89
Self-citationMa, H., Liu, T., Qin, J., & Lin, B. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900776 · Cited by 66
Microfluidic isolation of highly pure embryonic stem cells using feeder-separated co-culture system
Chen, Q., Wu, J., Zhuang, Q., Lin, X., Zhang, J., & Lin, J. (2013) · Scientific Reports · doi:10.1038/srep02433 · Cited by 54
Self-citationWei, H., Li, H., Mao, S., & Lin, J. (2011) · Analytical Chemistry · doi:10.1021/ac201709f · Cited by 49
Self-citationDevelopment of a Multiplex Sandwich Aptamer Microarray for the Detection of VEGF165 and Thrombin
Sosic, A., Meneghello, A., Antognoli, A., Cretaio, E., & Gatto, B. (2013) · Sensors · doi:10.3390/s131013425 · Cited by 25
Growing a blood vessel network
Baumann, K. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3533 · Cited by 13
Co-culture Microdevice with Oxygen Gradient for Tumor Microenvironment Model and Metastasis Imaging
Shiwa, T., Uchida, H., & Tsukada, K. (2012) · American Journal of Biomedical Engineering · doi:10.5923/j.ajbe.20120204.04 · Cited by 8
David, R. (2013) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3547 · Cited by 4
Cited by
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Galan, E. A., Zhao, H., Wang, X., Dai, Q., Huck, W. T. S., & Ma, S. (2020) · Matter · doi:10.1016/j.matt.2020.08.034 · Cited by 189
Sonker, M., Sahore, V., & Woolley, A. T. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.07.043 · Cited by 171
“[38] reported a PDMS microfluidic device for cell culture and used aptamerfunctionalized microchannels for analysis of vascular endothelial growth factor (VEGF).”
MethodBiochemical analysis on microfluidic chips
Wu, J., He, Z., Chen, Q., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.03.013 · Cited by 162
Self-citation
Metadata
- Authors
- Lin, X., Chen, Q., Liu, W., Zhang, J., Wang, S., Lin, Z., & Lin, J.-M.
- Affiliations
- Beijing University of Chemical Technology (CN)
- Tsinghua University (CN)
- First Affiliated Hospital of Fujian Medical University (CN)
- Corresponding author
- Lin, Jin-Ming
- Venue
- Scientific Reports
- Published
- 2015-04-23
- Volume
- 5
- Issue
- 1
- Pages
- 9643-9643
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5386116
- OpenAlex
- W1971862315
- Semantic Scholar
- 3503d8f1a2bc91d8fafaf0f9ce3da2fb610a156f
- Cited by
- 67
- References
- 36
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 7 · 2019: 13 · 2018: 6 · 2017: 16 · 2016: 6 · 2015: 2
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (91213305, 81373373, 214350002)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- cervical cancer, cell migration, hypoxia, oxygen concentration, VEGF165, microfluidics, co-culture, aptasensor, cell-to-cell communication, intercellular distance, HIF-1α, reactive oxygen species, CaSki cells, human umbilical vein endothelial cells
- MeSH terms
- Cell Communication, Cell Movement, Uterine Cervical Neoplasms, Female, Humans, Oxygen, Biomarkers, Cell Hypoxia, Reactive Oxygen Species, Coculture Techniques, Vascular Endothelial Growth Factor A, Cell Line, Tumor, Microfluidic Analytical Techniques, Hypoxia-Inducible Factor 1, alpha Subunit, Aptamers, Nucleotide, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.