Optofluidic analysis system for amplification-free, direct detection of Ebola infection
Open accessThe DOI matches its Crossref record.
Abstract
The massive outbreak of highly lethal Ebola hemorrhagic fever in West Africa illustrates the urgent need for diagnostic instruments that can identify and quantify infections rapidly, accurately and with low complexity. Here, we report on-chip sample preparation, amplification-free detection and quantification of Ebola virus on clinical samples using hybrid optofluidic integration. Sample preparation and target preconcentration are implemented on a PDMS-based microfluidic chip (automaton), followed by single nucleic acid fluorescence detection in liquid-core optical waveguides on a silicon chip in under ten minutes. We demonstrate excellent specificity, a limit of detection of 0.2 pfu/mL and a dynamic range of thirteen orders of magnitude, far outperforming other amplification-free methods. This chip-scale approach and reduced complexity compared to gold standard RT-PCR methods is ideal for portable instruments that can provide immediate diagnosis and continued monitoring of infectious diseases at the point-of-care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Point-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Rapid and Fully Microfluidic Ebola Virus Detection with CRISPR-Cas13a
Qin, P., Park, M., Alfson, K. J., Tamhankar, M., Carrion, R., Patterson, J. L., Griffiths, A., He, Q., Yildiz, A., Mathies, R., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00239 · Cited by 311
Self-citationOptical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
An Alternative Medical Diagnosis Method: Biosensors for Virus Detection
Saylan, Y., Erdem, Ö., Ünal, S., & Denizli, A. (2019) · Biosensors · doi:10.3390/bios9020065 · Cited by 264
Soler, M., Estevez, M. C., Cardenosa-Rubio, M., Astua, A., & Lechuga, L. M. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01180 · Cited by 189
Point-of-care-testing of nucleic acids by microfluidics
Zhang, L., Ding, B., Chen, Q., Feng, Q., Lin, L., & Sun, J. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.07.013 · Cited by 162
Field-Effect Transistor Biosensor for Rapid Detection of Ebola Antigen
Chen, Y., Ren, R., Pu, H., Guo, X., Chang, J., Zhou, G., Mao, S., Kron, M., & Chen, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-11387-7 · Cited by 162
Ngo, H. T., Freedman, E., Odion, R. A., Strobbia, P., De Silva Indrasekara, A. S., Vohra, P., Taylor, S. M., & Vo-Dinh, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-21615-3 · Cited by 66
Machine learning at the edge for AI-enabled multiplexed pathogen detection
Ganjalizadeh, V., Meena, G. G., Stott, M. A., Hawkins, A. R., & Schmidt, H. (2023) · Scientific Reports · doi:10.1038/s41598-023-31694-6 · Cited by 24
Self-citation
Metadata
- Authors
- Cai, H., Parks, J. W., Wall, T. A., Stott, M. A., Stambaugh, A., Alfson, K., Griffiths, A., Mathies, R. A., Carrion, R., Patterson, J. L., Hawkins, A. R., & Schmidt, H.
- Venue
- Scientific Reports
- Published
- 2015-09-25
- Volume
- 5
- Issue
- 1
- Pages
- 14494-14494
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2415054003
- Cited by
- 123
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.