Ballistocardiogram: Mechanism and Potential for Unobtrusive Cardiovascular Health Monitoring
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
For more than a century, it has been known that the body recoils each time the heart ejects blood into the arteries. These subtle cardiogenic body movements have been measured with increasingly convenient ballistocardiography (BCG) instruments over the years. A typical BCG measurement shows several waves, most notably the “I”, “J” and “K” waves. However, the mechanism for the genesis of these waves has remained elusive. We formulated a simple mathematical model of the BCG waveform. We showed that the model could predict the BCG waves as well as physiologic timings and amplitudes of the major waves. The validated model reveals that the principal mechanism for the genesis of the BCG waves is blood pressure gradients in the ascending and descending aorta. This new mechanistic insight may be exploited to allow BCG to realize its potential for unobtrusive monitoring and diagnosis of cardiovascular health and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Self-citationEchocardiography in aortic diseases: EAE recommendations for clinical practice
Evangelista, A., Flachskampf, F. A., Erbel, R., Antonini-Canterin, F., Vlachopoulos, C., Rocchi, G., Sicari, R., Nihoyannopoulos, P., Zamorano, J., on behalf of the European Association of Echocardiography, et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq056 · Cited by 536
Starr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. R. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398 · cited 3×
“As P1(t) starts to increase while P2(t) is still in diastole, δP12(t) builds up to cancel and then exceed δP01(t), thereby resulting in the I-J up-stroke (“(2)” in Fig.”
BackgroundInfluentialWave propagation in a model of the arterial circulation
Wang, J. J., & Parker, K. H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.007 · Cited by 270
Benetos, A., Thomas, F., Joly, L., Blacher, J., Pannier, B., Labat, C., Salvi, P., Smulyan, H., & Safar, M. E. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.061 · Cited by 221
Validation and reproducibility of aortic pulse wave velocity as assessed with velocity‐encoded MRI
Grotenhuis, H. B., Westenberg, J. J. M., Steendijk, P., van der Geest, R. J., Ottenkamp, J., Bax, J. J., Jukema, J. W., & de Roos, A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21886 · Cited by 204
Certain Molar Movements of the Human Body produced by the Circulation of the Blood.
Jw, G. (1877) · Europe PMC (PubMed Central) · Cited by 197
An Ear-Worn Vital Signs Monitor
He, D. D., Winokur, E. S., & Sodini, C. G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2459061 · Cited by 113 · cited 2×
“Meanwhile, δP01(t) exhibits a temporary decrease as P0(t) decreases fast near the dicrotic notch (“(4)” in Fig.”
BackgroundBerne, R. (1981) · Annual Review of Physiology · doi:10.1146/annurev.ph.43.030181.002041 · Cited by 112
Inan, O. T., Etemadi, M., Paloma, A., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/3/003 · Cited by 93 · cited 2×
“Third, the amplitude of the J-K down-stroke corresponds approximately to the peripheral PP scaled by the descending aortic cross-sectional area (“(3)” in Fig.”
BackgroundSelf-citationSCARBOROUGH, W. R., TALBOT, S. A., BRAUNSTEIN, J. R., RAPPAPORT, M. B., DOCK, W., SCARBOROUGH, W. R., HAMILTON, W. F., SMITH, J. E., NICKERSON, J. L., TALBOT, S. A., et al. (1956) · Circulation · doi:10.1161/01.cir.14.3.435 · Cited by 93
Starr, I., Horwitz, O., Mayock, R. L., & KRUMBHAAR, E. B. (1950) · Circulation · doi:10.1161/01.cir.1.5.1073 · Cited by 81
The relation of the ballistocardiogram to cardiac function
Starr, I. (1958) · The American Journal of Cardiology · doi:10.1016/0002-9149(58)90271-6 · Cited by 58
SCARBOROUGH, W. R., Folk, E. F., Smith, P. M., Condon, J. H., TALBOT, S. A., & SOPER, W. (1958) · The American Journal of Cardiology · doi:10.1016/0002-9149(58)90188-7 · Cited by 36 · cited 1×
“The M-N up-stroke is related to the subsequent increase in δP12(t) due to the faster decrease in P2(t) (“(6)” in Fig.”
BackgroundWide Frequency Range Force Ballistocardiogram: Its Correlation with Cardiovascular Dynamics
Reeves, T. J., Hefner, L. L., Jones, W. B., & SPARKS, J. E. (1957) · Circulation · doi:10.1161/01.cir.16.1.43 · Cited by 35
Fazeli, N., Kim, C., Rashedi, M., Chappell, A., Wang, S., MacArthur, R. G. G., McMurtry, M. S., Finegan, B. A., & Hahn, J. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1185-3 · Cited by 25
Self-citationHardt, S. E., Just, A., Bekeredjian, R., Kübler, W., Kirchheim, H. R., & Kuecherer, H. F. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.3.h1078 · Cited by 24
Cited by
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Self-citationThe functional role of cardiac activity in perception and action
Skora, L. I., Livermore, J. J. A., & Roelofs, K. (2022) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2022.104655 · Cited by 125
Metadata
- Authors
- Kim, C.-S., Ober, S. L., McMurtry, M. S., Finegan, B. A., Inan, O. T., Mukkamala, R., & Hahn, J.-O.
- Venue
- Scientific Reports
- Published
- 2016-08-09
- Volume
- 6
- Issue
- 1
- Pages
- 31297-31297
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2519059642
- Cited by
- 195
- References
- 19
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.