CoChat

Identification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram

Open access
Tang, Sung-Chun, Huang, Pei-Wen, Hung, Chi-Sheng, Shan, Shih-Ming, Lin, Yen-Hung, Shieh, Jiann-Shing, Lai, Dar-Ming, Wu, An-Yeu, Jeng, Jiann-Shing · 2017 · Scientific Reports
Cited by 66

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Atrial fibrillation (AF) detection is crucial for stroke prevention. We investigated the potential of quantitative analyses of photoplethysmogram (PPG) waveforms to identify AF. Continuous electrocardiogram (EKG) and fingertip PPG were recorded simultaneously in acute stroke patients (n = 666) admitted to an intensive care unit. Each EKG was visually labeled as AF (n = 150, 22.5%) or non-AF. Linear and nonlinear features from the pulse interval (PIN) and peak amplitude (AMP) of PPG waveforms were extracted from the first 1, 2, and 10 min of data. Logistic regression analysis revealed six independent PPG features feasibly identifying AF rhythm, including three PIN-related (mean, mean of standard deviation, and sample entropy), and three AMP-related features (mean of the root mean square of the successive differences, sample entropy, and turning point ratio) (all p < 0.01). The performance of the PPG analytic program comprising all 6 features that were extracted from the 2-min data was better than that from the 1-min data (area under the receiver operating characteristic curve was 0.972 (95% confidence interval 0.951–0.989) vs. 0.949 (0.929–0.970), p < 0.001 and was comparable to that from the 10-min data [0.973 (0.953–0.993)] for AF identification. In summary, our study established the optimal PPG analytic program in reliably identifying AF rhythm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep45644

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 20

  1. Sutamnartpong, P., Dharmasaroja, P. A., Ratanakorn, D. & Arunakul, I. Atrial fibrillation and paroxysmal atrial fibrillation detection in patients with acute ischemic stroke. Journal of stroke and cerebrovascular diseases: the official journal of National Stroke Association 23, 1138–1141, doi: 10.1016/j.jstrokecerebrovasdis.2013.09.032 (2014). · DOI
  2. Petrenas, A., Sornmo, L., Lukosevicius, A. & Marozas, V. Detection of occult paroxysmal atrial fibrillation. Medical & biological engineering & computing 53, 287–297, doi: 10.1007/s11517-014-1234-y (2015). · DOI
  3. Choe, W. C. et al. A Comparison of Atrial Fibrillation Monitoring Strategies After Cryptogenic Stroke (from the Cryptogenic Stroke and Underlying AF Trial). The American journal of cardiology 116, 889–893, doi: 10.1016/j.amjcard.2015.06.012 (2015). · DOI
  4. Sahni, R. Noninvasive monitoring by photoplethysmography. Clinics in perinatology 39, 573–583, doi: 10.1016/j.clp.2012.06.012 (2012). · DOI
  5. Lee, J., Reyes, B. A., McManus, D. D., Mathias, O. & Chon, K. H. Atrial fibrillation detection using a smart phone. Conference proceedings: … Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2012, 1177–1180, doi: 10.1109/embc.2012.6346146 (2012). · DOI · Paper page
  6. Dussault, C. et al. Electrocardiographic monitoring for detecting atrial fibrillation after ischemic stroke or transient ischemic attack: systematic review and meta-analysis. Circulation. Arrhythmia and electrophysiology 8, 263–269, doi: 10.1161/circep.114.002521 (2015). · DOI
  7. Keach, J. W., Bradley, S. M., Turakhia, M. P. & Maddox, T. M. Early detection of occult atrial fibrillation and stroke prevention. Heart (British Cardiac Society) 101, 1097–1102, doi: 10.1136/heartjnl-2015-307588 (2015). · DOI
  8. Bernstein, R. A. Detection of atrial fibrillation after cryptogenic stroke. Current treatment options in cardiovascular medicine 14, 298–304, doi: 10.1007/s11936-012-0180-y (2012). · DOI
  9. Chen-Scarabelli, C., Scarabelli, T. M., Ellenbogen, K. A. & Halperin, J. L. Device-detected atrial fibrillation: what to do with asymptomatic patients? Journal of the American College of Cardiology 65, 281–294, doi: 10.1016/j.jacc.2014.10.045 (2015). · DOI
  10. Stergiou, G. S., Karpettas, N., Protogerou, A., Nasothimiou, E. G. & Kyriakidis, M. Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation. Journal of human hypertension 23, 654–658, doi: 10.1038/jhh.2009.5 (2009). · DOI
  11. Verberk, W. J. & de Leeuw, P. W. Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review. Expert review of medical devices 9, 635–640, doi: 10.1586/erd.12.46 (2012). · DOI
  12. Lee, J., Reyes, B. A., McManus, D. D., Maitas, O. & Chon, K. H. Atrial fibrillation detection using an iPhone 4S. IEEE transactions on bio-medical engineering 60, 203–206, doi: 10.1109/tbme.2012.2208112 (2013). · DOI · Paper page
  13. Tang, S. C. et al. Complexity of heart rate variability predicts outcome in intensive care unit admitted patients with acute stroke. Journal of neurology, neurosurgery, and psychiatry 86, 95–100, doi: 10.1136/jnnp-2014-308389 (2015). · DOI
  14. Cao, Y. et al. Characterization of complexity in the electroencephalograph activity of Alzheimer’s disease based on fuzzy entropy. Chaos (Woodbury, N.Y.) 25, 083116, doi: 10.1063/1.4929148 (2015). · DOI
  15. Lu, C. W. et al. Complexity of intracranial pressure correlates with outcome after traumatic brain injury. Brain: a journal of neurology 135, 2399–2408, doi: 10.1093/brain/aws155 (2012). · DOI
  16. Chen, C. H. et al. Complexity of Heart Rate Variability Can Predict Stroke-In-Evolution in Acute Ischemic Stroke Patients. Scientific reports 5, 17552, doi: 10.1038/srep17552 (2015). · DOI
  17. Jeng, J. S., Huang, S. J., Tang, S. C. & Yip, P. K. Predictors of survival and functional outcome in acute stroke patients admitted to the stroke intensive care unit. Journal of the neurological sciences 270, 60–66, doi: 10.1016/j.jns.2008.01.015 (2008). · DOI
  18. Sposato, L. A., Cipriano, L. E., Riccio, P. M., Hachinski, V. & Saposnik, G. Very short paroxysms account for more than half of the cases of atrial fibrillation detected after stroke and TIA: a systematic review and meta-analysis. International journal of stroke: official journal of the International Stroke Society 10, 801–807, doi: 10.1111/ijs.12555 (2015). · DOI
  19. Rienzo MDi, C. P. & Parati, G. Arterial blood pressure processing. Wiley Encyclopedia of Biomedical Engineering (2006).
  20. Chong, J. W., Esa, N., McManus, D. D. & Chon, K. H. Arrhythmia discrimination using a smart phone. IEEE journal of biomedical and health informatics 19, 815–824, doi: 10.1109/jbhi.2015.2418195 (2015). · DOI · Paper page

Cited by

Metadata

Authors
Tang, S.-C., Huang, P.-W., Hung, C.-S., Shan, S.-M., Lin, Y.-H., Shieh, J.-S., Lai, D.-M., Wu, A.-Y., & Jeng, J.-S.
Venue
Scientific Reports
Published
2017-04-03
Volume
7
Issue
1
Pages
45644-45644
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2604936030
Cited by
66
References
9
FWCI
3.26
Type
journal article
Language
en
Open access
gold
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.