Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Recent research indicates that Photoplethysmography (PPG) signals carry more information than oxygen saturation level (SpO2) and can be utilized for affordable, fast, and noninvasive healthcare applications. All these encourage the researchers to estimate its feasibility as an alternative to many expansive, time-wasting, and invasive methods. This systematic review discusses the current literature on diagnostic features of PPG signal and their applications that might present a potential venue to be adapted into many health and fitness aspects of human life. The research methodology is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines 2020. To this aim, papers from 1981 to date are reviewed and categorized in terms of the healthcare application domain. Along with consolidated research areas, recent topics that are growing in popularity are also discovered. We also highlight the potential impact of using PPG signals on an individual’s quality of life and public health. The state-of-the-art studies suggest that in the years to come PPG wearables will become pervasive in many fields of medical practices, and the main domains include cardiology, respiratory, neurology, and fitness. Main operation challenges, including performance and robustness obstacles, are identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Qawqzeh, Y. K., Bajahzar, A. S., Jemmali, M., Otoom, M. M., & Thaljaoui, A. (2020) · BioMed Research International · doi:10.1155/2020/3764653 · Cited by 71 · cited 1×
“Others use machine learning models, like support vector machine [155] and logistic regression [156], to differentiate between PPG signals for diabetic patients and non-diabetic patients.”
MethodRetractedPage, M. J., Moher, D., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n160 · Cited by 13,262
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 2×
“This optical waveform, sometimes called digital volume pulse (DVP) [1], is associated with the change in blood volume in the microvascular bed of tissue containing valuable information about the cardiovascular, respiratory, and nervous systems [2].”
BackgroundRobust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · cited 1×
“In contact PPG [60–62], pulse rate is measured by placing a finger on the phone rear camera while, in non-contact [33,34,63], iPPG is extracted from the face, without the need for direct skin contact.”
BackgroundOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Kaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051 · cited 5×
“PPG was used to monitor obstructive sleep apnea in subjects with HF [138].”
MethodInfluentialGhamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · cited 2×
“Devices with a PPG sensor could be worn on wrist, nasal [55], ankle, and chest [17].”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Cited by
A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12
Metadata
- Authors
- Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S.
- Venue
- Healthcare
- Publisher
- MDPI AG
- Published
- 2022-03-16
- Volume
- 10
- Issue
- 3
- Pages
- 547
- ISSN
- 2227-9032 (ISSN-L)
- OpenAlex
- W4221007892
- Cited by
- 188
- References
- 30
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review. https://app.cochat.ai/papers/10.3390/healthcare10030547
- The paper
- Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S. (2022). Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review. Healthcare. https://doi.org/10.3390/healthcare10030547
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.