The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Patterned cell culture inside microfluidic devices
Abstract
This paper describes a simple plasma-based dry etching method that enables patterned cell culture inside microfluidic devices by allowing patterning, fluidic bonding and sterilization steps to be carried out in a single step. This plasma-based dry etching method was used to pattern cell-adhesive and non-adhesive areas on the glass and polystyrene substrates. The patterned substrate was used for selective attachment and growth of human umbilical vein endothelial cells, MDA-MB-231 human breast cancer cells, NIH 3T3 mouse fibroblasts, and primary rat cortical neurons. Finally, we have successfully combined the dry-patterned substrate with a microfluidic device. Patterned primary rat neurons were maintained for up to 6 days inside the microfluidic devices and the neurons' somas and processes were confined to the cell-adhesive region. The method developed in this work offers a convenient way of micropatterning biomaterials for selective attachment of cells on the substrates, and enables culturing of patterned cells inside microfluidic devices for a number of biological research applications where cells need to be exposed to well-controlled fluidic microenvironment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
pH-Dependent Thickness Behavior of Sequentially Adsorbed Layers of Weak Polyelectrolytes
Shiratori, S. S., & Rubner, M. F. (2000) · Macromolecules · doi:10.1021/ma991645q · Cited by 1,588
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Banker, G. A., & Goslin, K. (1998) · Cited by 1,290
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Isolation and culture of adult rat hippocampal neurons
Brewer, G. J. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00136-7 · Cited by 447
Microfabricated elastomeric stencils for micropatterning cell cultures
Folch, A., Jo, B.-H., Hurtado, O., Beebe, D. J., & Toner, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<346::aid-jbm14>3.0.co;2-h · Cited by 354
Biological surface engineering: a simple system for cell pattern formation
Zhang, S., Yan, L., Altman, M., Lässle, M., Nugent, H., Frankel, F., Lauffenburger, D. A., Whitesides, G. M., & Rich, A. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00014-9 · Cited by 344
Cited by
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
Self-citationA guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationAdvantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Self-citationNanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Microfabricated Biomaterials for Engineering 3D Tissues
Zorlutuna, P., Annabi, N., Camci‐Unal, G., Nikkhah, M., Cha, J. M., Nichol, J. W., Manbachi, A., Bae, H., Chen, S., & Khademhosseini, A. (2012) · Advanced Materials · doi:10.1002/adma.201104631 · Cited by 394
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Functional polymer surfaces for controlling cell behaviors
Chen, L., Yan, C., & Zheng, Z. (2018) · Materials Today · doi:10.1016/j.mattod.2017.07.002 · Cited by 358
Zhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Axonal mRNA in Uninjured and Regenerating Cortical Mammalian Axons
Taylor, A. M., Berchtold, N. C., Perreau, V. M., Tu, C. H., Li Jeon, N., & Cotman, C. W. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.6130-08.2009 · Cited by 328
Self-citationDanzer, K. M., Ruf, W. P., Putcha, P., Joyner, D., Hashimoto, T., Glabe, C., Hyman, B. T., & McLean, P. J. (2011) · The FASEB Journal · doi:10.1096/fj.10-164624 · Cited by 312
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Liu, D., Xie, Y., Shao, H., & Jiang, X. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901130 · Cited by 254
Microfluidic platform for hepatitis B viral replication study
Sodunke, T. R., Bouchard, M. J., & Noh, H. (. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9148-1 · Cited by 38
Metadata
- Authors
- Rhee, S. W., Taylor, A. M., Tu, C. H., Cribbs, D. H., Cotman, C. W., & Jeon, N. L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 1
- Pages
- 102
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2110133891
- Cited by
- 283
- References
- 17
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.