The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Power-free poly(dimethylsiloxane) microfluidic devices for gold nanoparticle-based DNA analysisElectronic supplementary information (ESI) available: Sample movie used for flow characterization, mathematical details of the one-dimensional diffusion model, and time course of the gold nanoparticle deposition. See http://www.rsc.org/suppdata/lc/b4/b403930k/
Abstract
An extremely simple, power-free pumping method for poly(dimethylsiloxane)(PDMS) microfluidic devices is presented. By exploiting the high gas solubility of PDMS, the energy for the pumping is pre-stored in the degassed bulk PDMS, therefore no additional structures other than channels and reservoirs are required. In a Y-shaped microchannel with cross section of 100 microm width x 25 microm height, this method has provided flow rate of 0.5-2 nL s(-1), corresponding to linear velocity of 0.2-0.8 mm s(-1), with good reproducibility. As an application of the power-free pumping, gold nanoparticle-based DNA analysis, which does not rely on the cross-linking mechanism between nanoparticles, has been implemented in a microchannel with three inlets. Target 15mer DNA has been easily and unambiguously discriminated from its single-base substituted mutant. Instead of colorimetric detection in a conventional microtube, an alternative detection technique suitable for microdevices has been discovered-observation of deposition on the PDMS surfaces. The channel layout enabled two simultaneous DNA analyses at the two interfaces between the three laminar streams.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A DNA-based method for rationally assembling nanoparticles into macroscopic materials
Mirkin, C. A., Letsinger, R. L., Mucic, R. C., & Storhoff, J. J. (1996) · Nature · doi:10.1038/382607a0 · Cited by 6,683
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
Gas sorption, diffusion, and permeation in poly(dimethylsiloxane)
Merkel, T. C., Bondar, V. I., Nagai, K., Freeman, B. D., & Pinnau, I. (2000) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(20000201)38:3<415::aid-polb8>3.0.co;2-z · Cited by 1,178
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Rapid Aggregation of Gold Nanoparticles Induced by Non-Cross-Linking DNA Hybridization
Sato, K., Hosokawa, K., & Maeda, M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034876s · Cited by 663
Self-citationAutonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Passively Driven Integrated Microfluidic System for Separation of Motile Sperm
Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S. (2003) · Analytical Chemistry · doi:10.1021/ac020579e · Cited by 356
A Picoliter-Volume Mixer for Microfluidic Analytical Systems
He, B., Burke, B. J., Zhang, X., Zhang, R., & Regnier, F. E. (2001) · Analytical Chemistry · doi:10.1021/ac000850x · Cited by 200
Fosser, K. A., & Nuzzo, R. G. (2003) · Analytical Chemistry · doi:10.1021/ac034634a · Cited by 72
A fluorogenic assay using pressure-driven flow on a microchip
Kerby, M. B., & Chien, R. (2001) · Electrophoresis · Cited by 33
Cited by
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Au, A. K., Huynh, W., Horowitz, L. F., & Folch, A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201504382 · Cited by 788
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Capillary pumps for autonomous capillary systems
Zimmermann, M., Schmid, H., Hunziker, P., & Delamarche, E. (2007) · Lab Chip · doi:10.1039/b609813d · Cited by 380
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Metadata
- Authors
- Hosokawa, K., Sato, K., Ichikawa, N., & Maeda, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 3
- Pages
- 181
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1885457900
- Cited by
- 260
- References
- 17
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.