The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array
Abstract
We present a high aspect ratio microfluidic device for culturing cells inside an array of microchambers with continuous perfusion of medium. The device was designed to provide a potential tool for cost-effective and automated cell culture. The single unit of the array consists of a circular microfluidic chamber 40 microm in height surrounded by multiple narrow perfusion channels 2 microm in height. The high aspect ratio (approximately 20) between the microchamber and the perfusion channels offers advantages such as localization of the cells inside the microchamber as well as creating a uniform microenvironment for cell growth. Finite element methods were used to simulate flow profile and mass transfer of the device. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C and was grown to confluency. The microfluidic cell culture array could potentially offer an affordable platform for a wide range of applications in high throughput cell-based screening, bioinformatics, synthetic biology, quantitative cell biology, and systems biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of a novel coronavirus in patients with severe acute respiratory syndrome
Drosten, C., Günther, S., Preiser, W., van der Werf, S., Brodt, H.-R., Becker, S., Rabenau, H., Panning, M., Kolesnikova, L., Fouchier, R. A. M., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030747 · Cited by 4,574
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Charati, S. G., & Stern, S. A. (1998) · Macromolecules · doi:10.1021/ma980387e · Cited by 423
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Low-cost microbioreactor for high-throughput bioprocessing
Kostov, Y. V., Harms, P. D., Randers‐Eichhorn, L., & Rao, G. (2000) · Biotechnology and Bioengineering · Cited by 194
Viravaidya, K., & Shuler, M. L. (2004) · Biotechnology Progress · doi:10.1021/bp034238d · Cited by 184
Cytosensor® Microphysiometer: technology and recent applications
Hafner, F. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00069-5 · Cited by 178
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
Prediction of Response to Drug Therapy of Cancer: A Review of In Vitro Assays
Bellamy, W. T. (1992) · Drugs · doi:10.2165/00003495-199244050-00002 · Cited by 83
Cited by
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Self-citationDesign of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Chang, R., Nam, J., & Sun, W. (2008) · Tissue Engineering Part A · doi:10.1089/ten.a.2007.0004 · Cited by 549
Intelligent Image-Activated Cell Sorting
Nitta, N., Sugimura, T., Isozaki, A., Mikami, H., Hiraki, K., Sakuma, S., Iino, T., Arai, F., Endo, T., Fujiwaki, Y., et al. (2018) · Cell · doi:10.1016/j.cell.2018.08.028 · Cited by 538
Metadata
- Authors
- Hung, P. J., Lee, P. J., Sabounchi, P., Aghdam, N., Lin, R., & Lee, L. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 1
- Pages
- 44
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2013240219
- Cited by
- 259
- References
- 12
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.