The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Membranes and microfluidics: a review
Open accessAbstract
The integration of mass transport control by means of membrane functionality into microfluidic devices has shown substantial growth over the last 10 years. Many different examples of mass transport control have been reported, demonstrating the versatile use of membranes. This review provides an overview of the developments in this area of research. Furthermore, it aims to bridge the fields of microfabrication and membrane science from a membrane point-of-view. First the basic terminology of membrane science will be discussed. Then the integration of membrane characteristics on-chip will be categorized based on the used fabrication method. Subsequently, applications in various fields will be reviewed. Considerations for the use of membranes will be discussed and a checklist with selection criteria will be provided that can serve as a starting point for those researchers interested in applying membrane-technology on-chip. Finally, opportunities for microfluidics based on proven membrane technology will be outlined. A special focus in this review is made on the membrane properties of polydimethylsiloxane (PDMS), since this material is frequently used nowadays in master replication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic principles of membrane technology
(1992) · Choice Reviews Online · doi:10.5860/choice.29-3919 · Cited by 4,115
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Membrane Technology and Applications
Baker, R. W. (2004) · Wiley eBooks · doi:10.1002/0470020393 · Cited by 3,956
The solution-diffusion model: a review
Wijmans, J. G., & Baker, R. W. (1995) · Journal of Membrane Science · doi:10.1016/0376-7388(95)00102-i · Cited by 3,499
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Advanced functional polymer membranes
Ulbricht, M. (2006) · Polymer · doi:10.1016/j.polymer.2006.01.084 · Cited by 2,029
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Gas sorption, diffusion, and permeation in poly(dimethylsiloxane)
Merkel, T. C., Bondar, V. I., Nagai, K., Freeman, B. D., & Pinnau, I. (2000) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(20000201)38:3<415::aid-polb8>3.0.co;2-z · Cited by 1,178
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Permeability and selectivity analysis for ultrafiltration membranes
Mehta, A., & Zydney, A. L. (2004) · Journal of Membrane Science · doi:10.1016/j.memsci.2004.09.040 · Cited by 410
Cell Culture in 3-Dimensional Microfluidic Structure of PDMS (polydimethylsiloxane)
Leclerc, E., Sakai, Y., & Fujii, T. (2003) · Biomedical Microdevices · doi:10.1023/a:1024583026925 · Cited by 324
Gao, J., Xu, J., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001126h · Cited by 257
Cabodi, M., Choi, N. W., Gleghorn, J. P., Lee, C. S. D., Bonassar, L. J., & Stroock, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054820t · Cited by 234
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Preconcentration of Proteins on Microfluidic Devices Using Porous Silica Membranes
Foote, R. S., Khandurina, J., Jacobson, S. C., & Ramsey, J. M. (2005) · Analytical Chemistry · doi:10.1021/ac049136w · Cited by 217
Membrane‐aerated microbioreactor for high‐throughput bioprocessing
Zanzotto, A., Szita, N., Boccazzi, P., Lessard, P., Sinskey, A. J., & Jensen, K. F. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20140 · Cited by 211
Electrophoretic Concentration of Proteins at Laser-Patterned Nanoporous Membranes in Microchips
Song, S., Singh, A. K., & Kirby, B. J. (2004) · Analytical Chemistry · doi:10.1021/ac0497151 · Cited by 168
Microchip-based chemical and biochemical analysis systems
Sato, K., Hibara, A., Tokeshi, M., Hisamoto, H., & Kitamori, T. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00225-9 · Cited by 165
A Microfabricated Dialysis Device for Sample Cleanup in Electrospray Ionization Mass Spectrometry
Xu, N., Lin, Y., Hofstadler, S. A., Matson, D. W., Call, C. J., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac980233x · Cited by 150
In situ fabricated porous filters for microsystems
Moorthy, J., & Beebe, D. J. (2003) · Lab on a Chip · doi:10.1039/b300450c · Cited by 147
Phase Separation Micromolding: A New Generic Approach for Microstructuring Various Materials
Vogelaar, L., Lammertink, R. G. H., Barsema, J. N., Nijdam, W., Bolhuis‐Versteeg, L. A. M., van Rijn, C. J. M., & Weßling, M. (2005) · Small · doi:10.1002/smll.200400128 · Cited by 143
Self-citationXiang, F., Lin, Y., Wen, J., Matson, D. W., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac981400w · Cited by 143
Liquid Membrane Operations in a Microfluidic Device for Selective Separation of Metal Ions
Maruyama, T., Matsushita, H., Uchida, J.-I., Kubota, F., Kamiya, N., & Goto, M. (2004) · Analytical Chemistry · doi:10.1021/ac049844h · Cited by 141
Phase Separation Micromolding—PSμM
Vogelaar, L., Barsema, J. N., van Rijn, C. J. M., Nijdam, W., & Weßling, M. (2003) · Advanced Materials · doi:10.1002/adma.200304949 · Cited by 141
Vollmer, A. P., Probstein, R. F., Gilbert, R., & Thorsen, T. (2005) · Lab on a Chip · doi:10.1039/b508097e · Cited by 140
Integrated Plastic Microfluidic Devices with ESI-MS for Drug Screening and Residue Analysis
Jiang, Y., Wang, P., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001474j · Cited by 137
Cooper, J. W., Chen, J., Li, Y., & Lee, C. S. (2003) · Analytical Chemistry · doi:10.1021/ac025768b · Cited by 130
Membrane-Based PDMS Microbioreactor for Perfused 3D Primary Rat Hepatocyte Cultures
Ostrovidov, S., Jiang, J., Sakai, Y., & Fujii, T. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048560.96140.ca · Cited by 127
Microchip Dialysis of Proteins Using in Situ Photopatterned Nanoporous Polymer Membranes
Song, S., Singh, A. K., Shepodd, T. J., & Kirby, B. J. (2004) · Analytical Chemistry · doi:10.1021/ac035290r · Cited by 123
Thorslund, S., Klett, O., Nikolajeff, F. K., Markides, K. E., & Bergquist, J. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-6385-7 · Cited by 120
Fabrication of miniature Clark oxygen sensor integrated with microstructure
Wu, C.-C., Yasukawa, T., Shiku, H., & Matsue, T. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.02.014 · Cited by 107
A water-powered osmotic microactuator
Su, Y.-C., Lin, L., & Pisano, A. P. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.805045 · Cited by 100
Microevaporators for Kinetic Exploration of Phase Diagrams
Leng, J., Lonetti, B., Tabeling, P., Joanicot, M., & Ajdari, A. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.084503 · Cited by 99
Long-term stable electroosmotic pump with ion exchange membranes
Brask, A., Kutter, J. P., & Bruus, H. (2005) · Lab on a Chip · doi:10.1039/b503626g · Cited by 97
Lion, N., Gellon, J., Jensen, H. M., et al. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00771-4 · Cited by 95
Metz, S., Trautmann, C., Bertsch, A., & Renaud, P. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/3/002 · Cited by 88
Insect Cell Culture in Microfluidic Channels
Walker, G. M., Ozers, M. S., & Beebe, D. J. (2002) · Biomedical Microdevices · doi:10.1023/a:1016088128057 · Cited by 84
Herber, S., Bomer, J. G., Olthuis, W., Bergveld, P., & van den Berg, A. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-3026-5 · Cited by 79
Membrane-based on-line optical analysis system for rapid detection of bacteria and spores
Floriano, P. N., Christodoulides, N., Romanovicz, D. K., Bernard, B., Simmons, G. W., Cavell, M., & McDevitt, J. T. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.046 · Cited by 69
Permeation-induced flows: Consequences for silicone-based microfluidics
Verneuil, E., Buguin, A., & Silberzan, P. (2004) · Europhysics Letters (EPL) · doi:10.1209/epl/i2004-10221-7 · Cited by 67
Micro-evaporation electrolyte concentrator
Timmer, B. H., van Delft, K. M., Olthuis, W., Bergveld, P., & van den Berg, A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00108-4 · Cited by 63
Jiang, Y., & Lee, C. S. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00718-x · Cited by 59
Lamoree, M. H., Tjaden, U. R., & van der Greef, J. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00430-5 · Cited by 54
de Jong, J., Ankoné, B., Lammertink, R. G. H., & Weßling, M. (2005) · Lab on a Chip · doi:10.1039/b509280a · Cited by 51
Self-citationEijkel, J. C. T., & van den Berg, A. (2005) · Lab on a Chip · doi:10.1039/b516903h · Cited by 50
Hybrid Microfabricated Device for Field Measurement of Atmospheric Sulfur Dioxide
Ohira, S.-I., Toda, K., Ikebe, S.-I., & Dasgupta, P. Κ. (2002) · Analytical Chemistry · doi:10.1021/ac025940b · Cited by 47
Tokuyama, T., Fujii, S., Sato, K., Abo, M., & Ōkubo, A. (2005) · Analytical Chemistry · doi:10.1021/ac048288o · Cited by 46
Mitrovski, S. M., & Nuzzo, R. G. (2005) · Lab on a Chip · doi:10.1039/b416671j · Cited by 46
Efficient electrospray ionization from polymer microchannels using integrated hydrophobic membranes
Wang, Y., Cooper, J. W., Lee, C. S., & DeVoe, D. L. (2004) · Lab on a Chip · doi:10.1039/b402825b · Cited by 45
Optimal membrane choice for microdialysis sampling of oligosaccharides
Torto, N., Bång, J., Richardson, S., et al. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00063-6 · Cited by 42
Voltage-controlled separation of proteins by electromobility focusing in a dialysis hollow fiber
Wang, Q., Lin, S., Warnick, K. F., Tolley, H. D., & Lee, M. L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01399-7 · Cited by 41
Towards a miniaturised system for dynamic field gradient focused separation of proteins
Myers, P., & Bartle, K. D. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.04.069 · Cited by 37
Functional Membrane-Implanted Lab-on-a-Chip for Analysis of Percent HDL Cholesterol
Kim, J.-E., Cho, J., & Paek, S. (2005) · Analytical Chemistry · doi:10.1021/ac0510484 · Cited by 31
Glucose recovery in a microfluidic microdialysis biochip
Hsieh, Y., & Zahn, J. D. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.11.039 · Cited by 30
Lamoree, M. H., van der Hoeven, R. A. M., Tjaden, U. R., & van der Greef, J. (1998) · Journal of Mass Spectrometry · Cited by 29
Cited by
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
Self-citationThe Current State of Silicone-Based Dielectric Elastomer Transducers
Madsen, F. B., Daugaard, A. E., Hvilsted, S., & Skov, A. L. (2016) · Macromolecular Rapid Communications · doi:10.1002/marc.201500576 · Cited by 439
Versatile and efficient pore network extraction method using marker-based watershed segmentation
Gostick, J. T. (2017) · Physical Review E · doi:10.1103/physreve.96.023307 · Cited by 423
Desalination at overlimiting currents: State-of-the-art and perspectives
Nikonenko, V. V., Kovalenko, A. V., Urtenov, M. K., Pismenskaya, N. D., Han, J., Sistat, P., & Pourcelly, G. (2014) · Desalination · doi:10.1016/j.desal.2014.01.008 · Cited by 405
Metadata
- Authors
- de Jong, J., Lammertink, R. G. H., & Wessling, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 9
- Pages
- 1125
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2155259189
- Cited by
- 483
- References
- 61
- FWCI
- 13.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.