The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Sintering, crystallisation and biodegradation behaviour of Bioglass®-derived glass–ceramics
Abstract
Sintering and crystallisation phenomena in powders of a typical bioactive glass composition (45S5 Bioglass) have been investigated in order to gain further understanding of the processes involved in the fabrication of Bioglass, based glass-ceramic scaffolds for tissue engineering applications. In situ experiments in an environmental scanning electron microscope with a heating stage were carried out to follow the morphology of Bioglass particles during sintering and crystallisation. Optimal processing parameters for the manufacture of Bioglass based glass-ceramic scaffolds by the foam-replica technique were determined. To assess the in vitro performance and bioreactivity of Bioglass -derived glass-ceramic scaffolds, the biodegradation of samples in simulated body fluid (SBF) was investigated using various techniques, including SEM, TEM, XRD and EDX. The mechanism of interaction of the glass-ceramic surface with SBF was determined, which involves (i) preferential dissolution at glass/crystal interfaces, (ii) break-down of crystalline particles into very fine grains through preferential dissolution at crystal structural defects, and (iii) amorphisation of the crystalline structure by introduction of point defects produced during ion exchange. The present report thus offers for the first time a complete assessment of the processing parameters, microstructure, and in vitro performance of Bioglass derived glass-ceramic scaffolds intended for bone tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Self-citationBonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
Third-Generation Biomedical Materials
Hench, L. L., & Polak, J. M. (2002) · Science · doi:10.1126/science.1067404 · Cited by 2,789
45S5 Bioglass®-derived glass–ceramic scaffolds for bone tissue engineering
Chen, Q. Z., Thompson, I. D., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.025 · Cited by 1,241
Self-citationXynos, I. D., Edgar, A. J., Buttery, L. D. K., Hench, L. L., & Polak, J. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<151::aid-jbm1001>3.0.co;2-d · Cited by 1,235
Hench, L. L., & Wilson, J. (1984) · Science · doi:10.1126/science.6093253 · Cited by 982
Direct chemical bond of bioactive glass‐ceramic materials to bone and muscle
Hench, L. L., & Paschall, H. A. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070304 · Cited by 942
Xynos, I. D., Hukkanen, M., Batten, J., Buttery, L. D. K., Hench, L. L., & Polak, J. M. (2000) · Calcified Tissue International · doi:10.1007/s002230001134 · Cited by 733
Bioactive Glass Stimulates the Secretion of Angiogenic Growth Factors and Angiogenesis in Vitro
Day, R. M. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.768 · Cited by 389
Roether, J. A., Boccaccini, A. R., Hench, L. L., Maquet, V, Gautier, S., & Jérôme, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00131-x · Cited by 358
Self-citationAssessment of polyglycolic acid mesh and bioactive glass for soft-tissue engineering scaffolds
Day, R. M., Boccaccini, A. R., Shurey, S., Roether, J. A., Forbes, A., Hench, L. L., & Gabe, S. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.043 · Cited by 330
Self-citationSolution effects on the surface reactions of a bioactive glass
Filgueiras, M. R., La Torre, G., & Hench, L. L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270405 · Cited by 286
Crystallization kinetics of tape cast bioactive glass 45S5
Clupper, D. C., & Hench, L. L. (2003) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(02)01857-4 · Cited by 200
Tissue Engineering: The Hope, the Hype, and the Future
Nerem, R. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1143 · Cited by 154
Cited by
Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering
Gerhardt, L.-C., & Boccaccini, A. R. (2010) · Materials · doi:10.3390/ma3073867 · Cited by 1,179
Self-citationCeramics for medical applications: A picture for the next 20 years
Chevalier, J., & Gremillard, L. (2009) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2008.08.025 · Cited by 754
Self-citationFernandes, H. R., Gaddam, A., Rebelo, A., Brazete, D., Stan, G. E., & Ferreira, J. M. F. (2018) · Materials · doi:10.3390/ma11122530 · Cited by 397
Polymer-bioceramic composites for tissue engineering scaffolds
Mohamad Yunos, D., Bretcanu, O., & Boccaccini, A. R. (2008) · Journal of Materials Science · doi:10.1007/s10853-008-2552-y · Cited by 361
Self-citationFernandes, J. S., Gentile, P., Pires, R. A., Reis, R. L., & Hatton, P. V. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.06.046 · Cited by 274
Metadata
- Authors
- Boccaccini, A. R., Chen, Q., Lefebvre, L., Gremillard, L., & Chevalier, J.
- Venue
- Faraday Discussions
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 136
- Pages
- 27
- ISSN
- 1359-6640 (ISSN-L)
- 1364-5498
- OpenAlex
- W2056187819
- Cited by
- 308
- References
- 15
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.