The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Microfluidic consecutive flow-focusing droplet generators
Abstract
This article describes emulsification in a microfluidic double droplet generator (DDR) comprising two consecutive flow-focusing devices with locally modified surface chemistry. We generated W/O/W, O/O/W and O/W/O double emulsions with precisely controlled sizes and morphology of droplets. Secondly, by combining two mechanisms of droplet formation (the flow-focusing mechanism and the break up of liquid threads at T-junction) we produced multiple populations of droplets with varying size and/or composition. These droplets were used as the structural units for the formation of complex dynamic lattices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Tailor‐Made Polyelectrolyte Microcapsules: From Multilayers to Smart Containers
Peyratout, C. S., & Dähne, L. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300568 · Cited by 1,031
Xu, S., Nie, Z., Seo, M., Lewis, P., Kumacheva, E., Stone, H. A., Garstecki, P., Weibel, D. B., Gitlin, I., & Whitesides, G. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462226 · Cited by 830
Self-citationEfimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Electric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 754
Nisisako, T., Torii, T., Takahashi, T., & Takizawa, Y. (2006) · Advanced Materials · doi:10.1002/adma.200502431 · Cited by 724
Nie, Z., Li, W., Seo, M., Xu, S., & Kumacheva, E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060882n · Cited by 689
Self-citationOkushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Self-citationDroplet formation in a microchannel network
Nisisako, T., Torii, T., & Higuchi, T. (2002) · Lab Chip · doi:10.1039/b108740c · Cited by 607
Perfectly Monodisperse Microbubbling by Capillary Flow Focusing
Gañán-Calvo, A. M., & Gordillo, J. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.274501 · Cited by 587
A Microfluidic Device for Conducting Gas-Liquid-Solid Hydrogenation Reactions
Kobayashi, J., Mori, Y., Okamoto, K., Akiyama, R., Ueno, M., Kitamori, T., & Kobayashi, S. (2004) · Science · doi:10.1126/science.1096956 · Cited by 576
Polymer Particles with Various Shapes and Morphologies Produced in Continuous Microfluidic Reactors
Nie, Z., Xu, S., Seo, M., Lewis, P. C., & Kumacheva, E. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042494w · Cited by 531
Self-citationOrdered and Disordered Patterns in Two-Phase Flows in Microchannels
Dreyfus, R., Tabeling, P., & Willaime, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.144505 · Cited by 404
Hung, L.-H., Choi, K. M., Tseng, W.-Y., Tan, Y.-C., Shea, K. J., & Lee, A. P. (2006) · Lab on a Chip · doi:10.1039/b513908b · Cited by 392
Microfluidic Production of Biopolymer Microcapsules with Controlled Morphology
Zhang, H., Tumarkin, E., Peerani, R., Nie, Z., Sullan, R. M. A., Walker, G. C., & Kumacheva, E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0635682 · Cited by 374
Self-citationAn Axisymmetric Flow‐Focusing Microfluidic Device
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005) · Advanced Materials · doi:10.1002/adma.200401738 · Cited by 370
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
Controlled formulation of monodisperse double emulsions in a multiple-phase microfluidic system
Nisisako, T., Okushima, S., & Torii, T. (2005) · Soft Matter · doi:10.1039/b501972a · Cited by 335
Controlled Microfluidic Encapsulation of Cells, Proteins, and Microbeads in Lipid Vesicles
Tan, Y.-C., Hettiarachchi, K., Siu, M., Pan, Y.-R., & Lee, A. P. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056641h · Cited by 278
Continuous Microfluidic Reactors for Polymer Particles
Seo, M., Nie, Z., Xu, S., Mok, M., Lewis, P. C., Graham, R., & Kumacheva, E. (2005) · Langmuir · doi:10.1021/la050519e · Cited by 253
Self-citationRohr, T., Ogletree, D. F., Švec, F., et al. (2003) · Advanced Functional Materials · doi:10.1002/adfm.200304229 · Cited by 220
Coalescence of Two Immiscible Liquid Drops
Torza, S., & Mason, S. G. (1969) · Science · doi:10.1126/science.163.3869.813 · Cited by 195
Droplet breakup in microfluidic junctions of arbitrary angles
Ménétrier-Deremble, L., & Tabeling, P. (2006) · Physical Review E · doi:10.1103/physreve.74.035303 · Cited by 190
Hatakeyama, T., Chen, D. L., & Ismagilov, R. F. (2006) · Journal of the American Chemical Society · doi:10.1021/ja057720w · Cited by 186
Using nanoliter plugs in microfluidics to facilitate and understand protein crystallization
Zheng, B., Gerdts, C. J., & Ismagilov, R. F. (2005) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2005.08.009 · Cited by 173
Xiao, D., Zhang, H., & Wirth, M. J. (2002) · Langmuir · doi:10.1021/la0205553 · Cited by 158
A rapid prototyping technique for the fabrication of solvent-resistant structures
Harrison, C. K., Cabral, J. T., Stafford, C. M., Karim, A., & Amis, E. J. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/021 · Cited by 115
Hydrodynamic micro-encapsulation of aqueous fluids and cells via ‘on the fly’ photopolymerization
Oh, H.-J., Kim, S.-H., Baek, J.-Y., Seong, G. H., & Lee, S.-H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/2/013 · Cited by 96
Preparation of Hydrophilic Poly(dimethylsiloxane) Stamps by Plasma-Induced Grafting
He, Q., Liu, Z., Xiao, P., Liang, R., He, N., & Lu, Z. (2003) · Langmuir · doi:10.1021/la020785h · Cited by 64
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Designer emulsions using microfluidics
Shah, R. K., Shum, H. C., Rowat, A. C., Lee, D., Agresti, J. J., Utada, A. S., Chu, L.-Y., Kim, J.-W., Fernandez-Nieves, A., Martinez, C. J., et al. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70053-1 · Cited by 766
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Gokmen, M. T., & Du Prez, F. E. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.07.006 · Cited by 492
Multiphase flow microfluidics for the production of single or multiple emulsions for drug delivery
Zhao, C.-X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.009 · Cited by 451
Metadata
- Authors
- Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E.
- Venue
- Soft Matter
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 3
- Issue
- 8
- Pages
- 986
- ISSN
- 1744-683X (ISSN-L)
- 1744-6848
- OpenAlex
- W1983450178
- Cited by
- 263
- References
- 40
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.