Carbon nanotube-modified microelectrodes for simultaneous detection of dopamine and serotonin in vivo
Abstract
Dopamine and serotonin are important neurotransmitters that interact in the brain. While dopamine is easily detected with electrochemical sensors, the detection of serotonin is more difficult because reactive species formed after oxidation can adsorb to the electrode, reducing sensitivity. Carbon nanotube treatments of electrodes have been used to increase the sensitivity, promote electron transfer, and reduce fouling. Most methods have focused on nanotube coatings of large electrodes and slower electrochemical techniques that are not conducive to measurements in vivo. In this study, we investigated carbon-fiber microelectrodes modified with single-walled carbon nanotubes for the co-detection of dopamine and serotonin in vivo. Using fast-scan cyclic voltammetry, S/N ratios for the neurotransmitters increased after nanotube coating. Electrocatalytic effects of nanotubes were not apparent at fast scan rates but faster kinetics were observed with slower scanning. Nanotube-modified microelectrodes showed significantly less fouling after exposure to serotonin than bare electrodes. The nanotube-modified electrodes were used to monitor stimulated dopamine and serotonin changes simultaneously in the striatum of anesthetized rat after administration of a serotonin synthetic precursor. These studies show that nanotube-coated microelectrodes can be used with fast scanning techniques and are advantageous for in vivo measurements of neurotransmitters because of their greater sensitivity and resistance to fouling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanobeam Mechanics: Elasticity, Strength, and Toughness of Nanorods and Nanotubes
Wong, E. W., Sheehan, P. E., & Lieber, C. M. (1997) · Science · doi:10.1126/science.277.5334.1971 · Cited by 4,810
Individual single-wall carbon nanotubes as quantum wires
Tans, S. J., Devoret, M. H., Dai, H., Thess, A., Smalley, R. E., Geerligs, L. J., & Dekker, C. (1997) · Nature · doi:10.1038/386474a0 · Cited by 2,939
Liu, J., Rinzler, A. G., Dai, H., Hafner, J. H., Bradley, R. K., Boul, P. J., Lu, A., Iverson, T., Shelimov, K., Huffman, C. B., et al. (1998) · Science · doi:10.1126/science.280.5367.1253 · Cited by 2,903
Solubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Effect of Chemical Oxidation on the Structure of Single-Walled Carbon Nanotubes
Zhang, J., Zou, H., Qing, Q., Yang, Y., Li, Q., Liu, Z., Guo, X., & Du, Z. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp027500u · Cited by 1,152
Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
Musameh, M., Wang, J., Merkoci, A., & Lin, Y. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00451-4 · Cited by 1,066
Serotonin-dopamine interaction and its relevance to schizophrenia
(1996) · American Journal of Psychiatry · doi:10.1176/ajp.153.4.466 · Cited by 823
Carbon Nanotube Purification: Preparation and Characterization of Carbon Nanotube Paste Electrodes
Valentini, F., Amine, A., Orlanducci, S., Terranova, M. L., & Palleschi, G. (2003) · Analytical Chemistry · doi:10.1021/ac0300237 · Cited by 540
Functionalization of Carbon Nanotubes
Hirsch, A., & Vostrowsky, O. (2005) · Topics in Current Chemistry · doi:10.1007/b98169 · Cited by 460
Psychoanalytical Electrochemistry: Dopamine and Behavior
Venton, B. J., & Wightman, R. M. (2003) · Analytical Chemistry · doi:10.1021/ac031421c · Cited by 421
Self-citationHeien, M. L. A. V., Phillips, P. E. M., Stuber, G. D., Seipel, A. T., & Wightman, R. M. (2003) · The Analyst · doi:10.1039/b307024g · Cited by 385
Subsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes
Bath, B. D., Michael, D. J., Trafton, B. J., Joseph, J. D., Runnels, P. L., & Wightman, R. M. (2000) · Analytical Chemistry · doi:10.1021/ac000849y · Cited by 363
Nagy, G., Gerhardt, G. A., Oke, A. F., Rice, M. E., Adams, R. N., Szentirmay, M. N., & Martin, C. R. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(85)80052-8 · Cited by 321
Microelectrodes for the Measurement of Catecholamines in Biological Systems
Cahill, P. S., Walker, Q. D., Finnegan, J. M., Mickelson, G. E., Travis, E. R., & Wightman, R. M. (1996) · Analytical Chemistry · doi:10.1021/ac960347d · Cited by 295
Arbuthnott, G. W., & Wickens, J. (2007) · Trends in Neurosciences · doi:10.1016/j.tins.2006.12.003 · Cited by 274
Fast-scan cyclic voltammetry of 5-hydroxytryptamine
Jackson, B. P., Dietz, S. M., & Wightman, R. M. (1995) · Analytical Chemistry · doi:10.1021/ac00102a015 · Cited by 268
DuVall, S. H., & McCreery, R. L. (1999) · Analytical Chemistry · doi:10.1021/ac990399d · Cited by 256
Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration
Venton, B. J., Troyer, K. P., & Wightman, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac010819a · Cited by 174
Self-citationJones, S. R., Garris, P. A., & Wightman, R. M. (1995) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)10623-x · Cited by 165
Fuxé, K., Butcher, L. L., & Engel, J. A. (1971) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1971.tb08673.x · Cited by 153
Carbon nanotubes (CNTs) For the development of electrochemical biosensors
Lin, Y. (2005) · Frontiers in bioscience · doi:10.2741/1545 · Cited by 136
Serotonin-Dopamine Interaction as a Focus of Novel Antidepressant Drugs
Esposito, E. (2006) · Current Drug Targets · doi:10.2174/138945006775515455 · Cited by 107
Modifications of single-wall carbon nanotubes upon oxidative purification treatments
nez, M. T. M., Callejas, M. A., Benito, A. M., Cochet, M., Seeger, T., Abo-Elkhier, A. N., Schreiber, J., Gordon, C., Marhic, C., Chauvet, O., et al. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/7/301 · Cited by 106
Dispersion in flow injection analysis measured with microvoltammetric electrodes
Kristensen, E. W., Wilson, R. L., & Wightman, R. M. (1986) · Analytical Chemistry · doi:10.1021/ac00295a073 · Cited by 98
Psychostimulants and monoamine transporters: upsetting the balance
Elliott, J. M., & Beveridge, T. J. R. (2004) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2004.09.005 · Cited by 72
Fast cyclic voltammetry: improved sensitivity to dopamine with extended oxidation scan limits
Hafizi, S., Kruk, Z. L., & Stamford, J. A. (1990) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(90)90080-y · Cited by 64
(2000) · doi:10.1002/1520-6394(2000)12:1+<2::aid-da2>3.0.co;2-4
Cited by
Review: Carbon nanotube based electrochemical sensors for biomolecules
Jacobs, C. B., Peairs, M. J., & Venton, B. J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.009 · Cited by 987
Self-citationMetallophthalocyanine-based molecular materials as catalysts for electrochemical reactions
Zagal, J. H., Griveau, S., Silva, J. F., Nyokong, T., & Bedioui, F. (2010) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2010.05.001 · Cited by 581
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.049 · Cited by 577
Self-citationNew trends in the electrochemical sensing of dopamine
Jackowska, K., & Krysinski, P. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6578-2 · Cited by 461
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Metadata
- Authors
- Swamy, B. E. K., & Venton, B. J.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 132
- Issue
- 9
- Pages
- 876
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2076950982
- Cited by
- 314
- References
- 27
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.