The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Enzymatic sensing with organic electrochemical transistors
Abstract
Since their development in the 1980's organic electrochemical transistors (OECTs) have attracted a great deal of interest for biosensor applications. Coupled with the current proliferation of organic semiconductor technologies, these devices have the potential to revolutionize healthcare by making point-of-care and home-based medical diagnostics widely available. Unfortunately, their mechanism of operation is poorly understood, and this hinders further development of this important technology. In this paper glucose sensors based on OECTs and the redox enzyme glucose oxidase are investigated. Through appropriate scaling of the transfer characteristics at various glucose concentrations, a universal curve describing device operation is shown to exist. This result elucidates the underlying device physics and establishes a connection between sensor response and analyte concentration. This improved understanding paves the way for rational optimization of enzymatic sensors based on organic electrochemical transistors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
(2002) · Kluwer Academic Publishers eBooks · doi:10.1007/b117561 · Cited by 13,963
(1981) · Handbook of Exploration Geochemistry · doi:10.1016/b978-0-444-41930-9.50014-3 · Cited by 2,896
The physics of semiconductor devices
Grubin, H. (1979) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1979.1069942 · Cited by 2,753
Someya, T., Sekitani, T., Iba, S., Kato, Y., Kawaguchi, H., & Sakurai, T. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401918101 · Cited by 1,921
Paul, E. W., Ricco, A. J., & Wrighton, M. S. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100254a028 · Cited by 1,026
Steady‐State and Transient Behavior of Organic Electrochemical Transistors
Bernards, D. A., & Malliaras, G. G. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601239 · Cited by 997
Self-citationOrganic materials for printed electronics
Berggren, M., Nilsson, D., & Robinson, N. D. (2007) · Nature Materials · doi:10.1038/nmat1817 · Cited by 663
White, H. S., Kittlesen, G. P., & Wrighton, M. S. (1984) · Journal of the American Chemical Society · doi:10.1021/ja00330a070 · Cited by 634
Chemical and biological sensors based on organic thin-film transistors
Mabeck, J. T., & Malliaras, G. G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3390-2 · Cited by 479
Self-citationElectronic control of Ca2+ signalling in neuronal cells using an organic electronic ion pump
Isaksson, J., Kjäll, P., Nilsson, D., Robinson, N., Berggren, M., & Richter-Dahlfors, A. (2007) · Nature Materials · doi:10.1038/nmat1963 · Cited by 418
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Self-citationSynthesis, Properties, and Applications of Hollow Micro-/Nanostructures
Wang, X., Feng, J., Bai, Y., Zhang, Q., & Yin, Y. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00731 · Cited by 1,456
PEDOT:PSS for Flexible and Stretchable Electronics: Modifications, Strategies, and Applications
Fan, X., Nie, W., Tsai, H., Wang, N., Huang, H., Cheng, Y., Wen, R., Ma, L., Yan, F., & Xia, Y. (2019) · Advanced Science · doi:10.1002/advs.201900813 · Cited by 1,028
In vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,012
Self-citationOrganic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
A sensitivity-enhanced field-effect chiral sensor
Torsi, L., Farinola, G. M., Marinelli, F., Tanese, M. C., Omar, O. H., Valli, L., Babudri, F., Palmisano, F., Zambonin, P. G., & Naso, F. (2008) · Nature Materials · doi:10.1038/nmat2167 · Cited by 440
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Device physics of organic electrochemical transistors
Friedlein, J. T., McLeod, R. R., & Rivnay, J. (2018) · Organic Electronics · doi:10.1016/j.orgel.2018.09.010 · Cited by 429
Liao, C., Mak, C., Zhang, M., Chan, H. L. W., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201404378 · Cited by 378
Wen, Y., & Xu, J. (2017) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.28482 · Cited by 378
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
The organic electrochemical transistor for biological applications
Strakosas, X., Bongo, M., & Owens, R. M. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41735 · Cited by 350
Lin, P., Luo, X., Hsing, I., & Yan, F. (2011) · Advanced Materials · doi:10.1002/adma.201102017 · Cited by 346
Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002117 · Cited by 310
Kukhta, N. A., Marks, A., & Luscombe, C. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00266 · Cited by 309
Kergoat, L., Piro, B., Berggren, M., Horowitz, G., & Pham, M.-C. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5363-y · Cited by 303
Khodagholy, D., Curto, V. F., Fraser, K. J., Gurfinkel, M., Byrne, R., Diamond, D., Malliaras, G. G., Benito-Lopez, F., & Owens, R. M. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm15716k · Cited by 303
Self-citationOrganic Electrochemical Transistors with Maximum Transconductance at Zero Gate Bias
Rivnay, J., Leleux, P., Sessolo, M., Khodagholy, D., Hervé, T., Fiocchi, M., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201303080 · Cited by 300
Self-citationThe Application of Organic Electrochemical Transistors in Cell‐Based Biosensors
Lin, P., Yan, F., Yu, J., Chan, H. L. W., & Yang, M. (2010) · Advanced Materials · doi:10.1002/adma.201000971 · Cited by 299
Organic Electronics at the Interface with Biology
Owens, R. M., & Malliaras, G. G. (2010) · MRS Bulletin · doi:10.1557/mrs2010.583 · Cited by 294
Self-citationFlexible Electrochemical Biosensors for Health Monitoring
Yang, A., & Yan, F. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00534 · Cited by 122
Cramer, T., Chelli, B., Murgia, M., Barbalinardo, M., Bystrenova, E., de Leeuw, D. M., & Biscarini, F. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp44251a · Cited by 87
Metadata
- Authors
- Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G.
- Venue
- J. Mater. Chem.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 18
- Issue
- 1
- Pages
- 116-120
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2043008793
- Cited by
- 410
- References
- 22
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.