The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Electrochemical biosensors
Abstract
Electrochemical biosensors combine the sensitivity of electroanalytical methods with the inherent bioselectivity of the biological component. The biological component in the sensor recognizes its analyte resulting in a catalytic or binding event that ultimately produces an electrical signal monitored by a transducer that is proportional to analyte concentration. Some of these sensor devices have reached the commercial stage and are routinely used in clinical, environmental, industrial, and agricultural applications. The two classes of electrochemical biosensors, biocatalytic devices and affinity sensors, will be discussed in this critical review to provide an accessible introduction to electrochemical biosensors for any scientist (110 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Johnsson, B., Löfås, S., & Lindquist, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90424-r · Cited by 1,262
Mrksich, M., & Whitesides, G. M. (1996) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.25.060196.000415 · Cited by 850
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Kissinger, P. T., & Heineman, W. R. (1983) · Journal of Chemical Education · doi:10.1021/ed060p702 · Cited by 771
Self-citationGlucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Micropatterned Surfaces for Control of Cell Shape, Position, and Function
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1998) · Biotechnology Progress · doi:10.1021/bp980031m · Cited by 706
Wightman, R. M. (1981) · Analytical Chemistry · doi:10.1021/ac00232a004 · Cited by 544
Field effect transistor sensitive to penicillin
Caras, S., & Janata, J. (1980) · Analytical Chemistry · doi:10.1021/ac50062a035 · Cited by 514
Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications
Gregg, B. A., & Heller, A. (1990) · Analytical Chemistry · doi:10.1021/ac00202a007 · Cited by 479
Ultramicroelectrodes in Electrochemistry
Heinze, J. (1993) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199312681 · Cited by 470
Real-time measurement of transmitter release from single synaptic vesicles
Bruns, D., & Jahn, R. (1995) · Nature · doi:10.1038/377062a0 · Cited by 407
Impedance methods for electrochemical sensors using nanomaterials
Suni, I. I. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.03.012 · Cited by 363
Lu, B., Smyth, M. R., & O'Kennedy, R. (1996) · The Analyst · doi:10.1039/an996210029r · Cited by 360
Microelectrodes for Measuring Local Oxygen Tension in Animal Tissues
Davies, P. W., & Brink, F. (1942) · Review of Scientific Instruments · doi:10.1063/1.1769961 · Cited by 358
Hodneland, C. D., Lee, Y.-S., Min, D.-H., & Mrksich, M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.072685299 · Cited by 346
Ohara, T. J., Rajagopalan, R., & Heller, A. (1993) · Analytical Chemistry · doi:10.1021/ac00071a031 · Cited by 281
Electronic Detection of Nucleic Acids
Umek, R. M., Lin, S. W., Vielmetter, J., Terbrueggen, R. H., Irvine, B., Yu, C. J., Kayyem, J. F., Yowanto, H., Blackburn, G. F., Farkas, D. H., et al. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60655-1 · Cited by 253
Hart, J. P., Crew, A., Crouch, E., Honeychurch, K. C., & Pemberton, R. M. (2004) · Analytical Letters · doi:10.1081/al-120030682 · Cited by 229
A conductometric biosensor for biosecurity
Muhammad-Tahir, Z., & Alocilja, E. C. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00020-4 · Cited by 220
Manufacturing of recombinant therapeutic proteins in microbial systems
Graumann, K., & Premstaller, A. (2006) · Biotechnology Journal · doi:10.1002/biot.200500051 · Cited by 208
Gold-based screen-printed sensor for detection of trace lead
Laschi, S., Palchetti, I., & Mascini, M. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.05.028 · Cited by 199
Chen, T. K., Luo, G., & Ewing, A. G. (1994) · Analytical Chemistry · doi:10.1021/ac00091a007 · Cited by 180
Chien, J. B., Wallingford, R. A., & Ewing, A. G. (1990) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1990.tb01918.x · Cited by 137
Comparison of antibody functionality using different immobilization methods
Danczyk, R., Krieder, B., North, A., Webster, T. J., HogenEsch, H., & Rundell, A. E. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10760 · Cited by 125
A nanotube array immunosensor for direct electrochemical detection of antigen–antibody binding
Yun, Y., Bange, A. F., Heineman, W. R., Halsall, H. B., Shanov, V. N., Dong, Z., Pixley, S. K., Behbehani, M. M., Jazieh, A. R., & Tu, Y. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.08.014 · Cited by 113
Self-citationГоголь, Э. В. (2000) · Talanta · doi:10.1016/s0039-9140(00)00507-5 · Cited by 109
Clinical review: hemodynamic monitoring in the intensive care unit.
Boldt, J. (2002) · Critical Care · doi:10.1186/cc1453 · Cited by 96
?Bananatrode? ? An electrochemical biosensor for dompamine
Sidwell, J., & RECHNITZ, G. A. (1985) · Biotechnology Letters · doi:10.1007/bf01166215 · Cited by 95
Kellermann, S., & Green, L. L. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00354-3 · Cited by 92
Bead-Based Electrochemical Immunoassay for Bacteriophage MS2
Thomas, J. H., Kim, S. K., Hesketh, P. J., Halsall, H. B., & Heineman, W. R. (2004) · Analytical Chemistry · doi:10.1021/ac035503c · Cited by 78
Self-citationYagiuda, K., Hemmi, A., Ito, S., Asano, Y., Fushinuki, Y., Chen, C., & Karube, I. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)85920-3 · Cited by 74
Electroanalytical Flow Measurements–Recent Advances
Trojanowicz, M., Szewczyńska, M., & Wcisło, M. (2003) · Electroanalysis · doi:10.1002/elan.200390041 · Cited by 69
Sung, W. J., & Bae, Y. H. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.04.027 · Cited by 58
Klonoff, D. C. (2004) · Diabetes Care · doi:10.2337/diacare.27.3.834 · Cited by 56
Application of the electrochemical concepts and techniques to amperometric biosensor devices
Lojou, É., & Bianco, P. (2006) · Journal of Electroceramics · doi:10.1007/s10832-006-2365-9 · Cited by 55
Palleschi, G., Mascini, M., Bernardi, L. R., & Zeppilli, P. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442677 · Cited by 47
Arslan, F., Yaşar, A., & Kιlιç, E. (2006) · Artificial Cells Blood Substitutes and Biotechnology · doi:10.1080/10731190500430289 · Cited by 43
Jankowski, J. A., Schroeder, T. J., Holz, R. W., & Wightman, R. M. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)36964-9 · Cited by 43
Immunoenzymatic assay using CHEMFET devices
Colapicchioni, C., Barbaro, A., Porcelli, F., & Giannini, I. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)80117-3 · Cited by 28
Functionalization of PVC membrane with ss oligonucleotides for a potentiometric biosensor
Shishkanová, T. V., Volf, R., Kronďák, M., & Král, V. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.11.014 · Cited by 26
Zur Anwendung der Transformations-Impedanzspektrometrie
Lorenz, W. E., & SCHULZE, K. (1975) · Journal of Electroanalytical Chemistry (1959) · doi:10.1016/0368-1874(75)85112-4 · Cited by 23
CHEMFET Devices for biomedical and environmental applications
Barbaro, A., Colapicchioni, C., Davini, E., Mazzamurro, G., Piotto, A., & Porcelli, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040605 · Cited by 22
Lactate biosensors for continuous monitoring
Mo, J.-W. (2004) · Frontiers in bioscience · doi:10.2741/1489 · Cited by 21
Amperometric sensor for fish freshness based on immobilized multi‐enzyme modified electrode
Hu, S., & Liu, C. (1997) · Electroanalysis · doi:10.1002/elan.1140091602 · Cited by 10
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Metadata
- Authors
- Ronkainen, N. J., Halsall, H. B., & Heineman, W. R.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 5
- Pages
- 1747
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W4232362978
- Cited by
- 1,945
- References
- 52
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.