The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
FRET-based sensor for imaging chromium(iii) in living cells
Abstract
On the basis of fluorescent resonance energy transfer from 1,8-naphthalimide to rhodamine, a fluorophore dyad (FD8) containing rhodamine and a naphthalimide moiety was synthesized as a Cr3+-selective fluorescent probe for monitoring Cr3+ in living cells with ratiometric fluorescent methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824
Interactions of chromium with microorganisms and plants
Cervantes, C., Campos‐García, J., Devars, S., Gutiérrez‐Corona, F., Loza‐Tavera, H., Guzmán, J. C. T., & Moreno‐Sánchez, R. (2001) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(01)00057-2 · Cited by 1,266
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
A Long-Wavelength Fluorescent Chemodosimeter Selective for Cu(II) Ion in Water
Dujols, V., Ford, F., & Czarnik, A. W. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971221g · Cited by 987
Imaging protein molecules using FRET and FLIM microscopy
Wallrabe, H., & Periasamy, A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.002 · Cited by 724
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065114a · Cited by 509
Kenmoku, S., Urano, Y., Kojima, H., & Nagano, T. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068740g · Cited by 461
Tang, B., Xing, Y., Li, P., Zhang, N., Yu, F., & Yang, G. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072572q · Cited by 413
Tuning the Selectivity of Two Chemosensors to Fe(III) and Cr(III)
Mao, J., Wang, L., Dou, W., Tang, X., Yan, Y., & Liu, W. (2007) · Organic Letters · doi:10.1021/ol7020687 · Cited by 380
A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide
Albers, A. E., Okreglak, V. S., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063308k · Cited by 375
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Self-citationFluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Phosphorescent chemosensors based on heavy-metal complexes
Zhao, Q., Li, F., & Huang, C. (2010) · Chemical Society Reviews · doi:10.1039/b915340c · Cited by 1,249
Self-citationFRET-Based Small-Molecule Fluorescent Probes: Rational Design and Bioimaging Applications
Yuan, L., Lin, W., Zheng, K., & Zhu, S. (2013) · Accounts of Chemical Research · doi:10.1021/ar300273v · Cited by 1,021
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Fluorescent, MRI, and colorimetric chemical sensors for the first-row d-block metal ions
Zhu, H., Fan, J., Wang, B., & Peng, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00285g · Cited by 437
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
“Alive” dyes as fluorescent sensors: fluorophore, mechanism, receptor and images in living cells
Qian, X., Xiao, Y., Xu, Y., Guo, X., Qian, J., & Zhu, W. (2010) · Chemical Communications · doi:10.1039/c0cc00686f · Cited by 316
Liu, W., Wang, Y., Bai, Z., Li, Y., Wang, Y., Chen, L., Xu, L., Diwu, J., Chai, Z., & Wang, S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b03914 · Cited by 256
Shanmugaraju, S., Joshi, S. A., & Mukherjee, P. S. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10406c · Cited by 252
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Metadata
- Authors
- Zhou, Z., Yu, M., Yang, H., Huang, K., Li, F., Yi, T., & Huang, C.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Issue
- 29
- Pages
- 3387
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W1973296012
- Cited by
- 379
- References
- 21
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.