The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Design, fabrication and implementation of a novel multi-parameter control microfluidic platform for three-dimensional cell culture and real-time imaging
Open accessAbstract
New and more biologically relevant in vitro models are needed for use in drug development, regenerative medicine, and fundamental scientific investigation. While the importance of the extracellular microenvironment is clear, the ability to investigate the effects of physiologically relevant biophysical and biochemical factors is restricted in traditional cell culture platforms. Moreover, the versatility for multi-parameter manipulation, on a single platform, with the optical resolution to monitor the dynamics of individual cells or small population is lacking. Here we introduce a microfluidic platform for 3D cell culture in biologically derived or synthetic hydrogels with the capability to monitor cellular dynamics in response to changes in their microenvironment. Direct scaffold microinjection, was employed to incorporate 3D matrices into microfluidic devices. Our system geometry permits a unique window for studying directional migration, e.g. sprouting angiogenesis, since sprouts grow predominantly in the microscopic viewing plane. In this study, we demonstrate the ability to generate gradients (non-reactive solute), surface shear, interstitial flow, and image cells in situ. Three different capillary morphogenesis assays are demonstrated. Human adult dermal microvascular endothelial cells (HMVEC-ad) were maintained in culture for up to 7 days during which they formed open lumen-like structures which was confirmed with confocal microscopy and by perfusion with fluorescent microspheres. In the sprouting assay, time-lapse movies revealed cellular mechanisms and dynamics (filopodial projection/retraction, directional migration, cell division and lumen formation) during tip-cell invasion of underlying 3D matrix and subsequent lumen formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Molecular mechanisms of blood vessel growth
Conway, E. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00281-9 · Cited by 1,030
Ingber, D. E., & Folkman, J. (1989) · The Journal of cell biology · doi:10.1083/jcb.109.1.317 · Cited by 868
Design of nanostructured biological materials through self-assembly of peptides and proteins
Zhang, S., Marini, D. M., Hwang, W., & Santoso, S. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00391-5 · Cited by 572
Diffusion and Convection in Collagen Gels: Implications for Transport in the Tumor Interstitium
Ramanujan, S., Pluen, A., McKee, T. D., Brown, E. B., Boucher, Y., & Jain, R. K. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73933-7 · Cited by 552
Chiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
Cited by
Is it time to start transitioning from 2D to 3D cell culture?
Jensen, C., & Teng, Y. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00033 · Cited by 1,640
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Self-citationMicrofluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Self-citationInterstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509
Self-citationOrgan-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
In Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
3D Bioprinting for Cartilage and Osteochondral Tissue Engineering
Daly, A. C., Freeman, F. E., Gonzalez‐Fernandez, T., Critchley, S. E., Nulty, J., & Kelly, D. J. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700298 · Cited by 334
Microfluidic 3D Cell Culture: Potential Application For Tissue-Based Bioassays
Li, X. (., Valadez, A. V., Zuo, P., & Nie, Z. (2012) · Bioanalysis · doi:10.4155/bio.12.133 · Cited by 319
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
Integrating perfusable vascular networks with a three-dimensional tissue in a microfluidic device
Nashimoto, Y., Hayashi, T., Kunita, I., Nakamasu, A., Torisawa, Y.-S., Nakayama, M., Takigawa-Imamura, H., Kotera, H., Nishiyama, K., Miura, T., et al. (2017) · Integrative Biology · doi:10.1039/c7ib00024c · Cited by 266
Biomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
In vitro model of tumor cell extravasation
Jeon, J. S., Zervantonakis, I. K., Chung, S., Kamm, R. D., & Charest, J. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056910 · Cited by 233
Self-citationConcentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Migration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
A quantitative microfluidic angiogenesis screen for studying anti-angiogenic therapeutic drugs
Kim, C., Kasuya, J., Jeon, J., Chung, S., & Kamm, R. D. (2015) · Lab on a Chip · doi:10.1039/c4lc00866a · Cited by 143
Self-citationHydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Belair, D. G., Whisler, J. A., Valdez, J., Velazquez, J., Molenda, J. A., Vickerman, V., Lewis, R., Daigh, C., Hansen, T. D., Mann, D. A., et al. (2015) · Stem Cell Reviews and Reports · doi:10.1007/s12015-014-9549-5 · Cited by 120
Self-citationLow levels of physiological interstitial flow eliminate morphogen gradients and guide angiogenesis
Shirure, V. S., Lezia, A., Tao, A., Alonzo, L. F., & George, S. C. (2017) · Angiogenesis · doi:10.1007/s10456-017-9559-4 · Cited by 117
A review of chemical gradient systems for cell analysis
Somaweera, H., Ibraguimov, A., & Pappas, D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.008 · Cited by 98
Simultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Self-citationChwalek, K., Bray, L. J., & Werner, C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.05.006 · Cited by 91
Organ-Tumor-on-a-Chip for Chemosensitivity Assay: A Critical Review
Kashaninejad, N., Nikmaneshi, M., Moghadas, H., Kiyoumarsi Oskouei, A., Rismanian, M., Barisam, M., Saidi, M., & Firoozabadi, B. (2016) · Micromachines · doi:10.3390/mi7080130 · Cited by 79
Quantification of angiogenic sprouting under different growth factors in a microfluidic platform
Del Amo, C., Borau, C., Gutiérrez, R., Asín, J., & García-Aznar, J. M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.026 · Cited by 32
Shin, Y., Lim, S., Kim, J., Jeon, J. S., Yoo, H., & Gweon, B. (2019) · Lab on a Chip · doi:10.1039/c9lc00352e · Cited by 26
Advances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Fish, A., Forster, J., Malik, V., & Kulkarni, A. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c18845 · Cited by 20
Metadata
- Authors
- Vickerman, V., Blundo, J., Chung, S., & Kamm, R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 9
- Pages
- 1468
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2094576343
- Cited by
- 340
- References
- 35
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.