The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Micromagnetic–microfluidic blood cleansing device
Abstract
Sepsis is a lethal disease caused by a systemic microbial infection that spreads via the bloodstream to overwhelm the body's defenses. Current therapeutic approaches are often suboptimal, in part, because they do not fully eliminate the pathogen, and hence the source of deadly toxins. Here we describe an extracorporeal blood cleansing device to selectively remove pathogens from contaminated blood and thereby enhance the patient's response to antibiotic therapy. Immunomagnetic microbeads were modified to create magnetic opsonins that were used to cleanse flowing human whole blood of Candida albicans fungi, a leading cause of sepsis-related deaths. The micromagnetic-microfluidic blood cleansing device generates magnetic field gradients across vertically stacked channels to enable continuous and high throughput separation of fungi from flowing whole blood. A multiplexed version of the device containing four parallel channels achieved over 80% clearance of fungi from contaminated blood at a flow rate of 20 mL/h in a single pass, a rate 1000 times faster than a previously described prototype micromagnetic-microfluidic cell separation system. These results provide the first proof-of-principle that a multiplexed micromagnetic-microfluidic separation system can be used to cleanse pathogens from flowing human blood at a rate and separation efficiency that is relevant for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
The immunopathogenesis of sepsis
Cohen, J. (2002) · Nature · doi:10.1038/nature01326 · Cited by 2,742
Cited by
Microchip-based immunomagnetic detection of circulating tumor cells
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20270g · Cited by 400
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Continuous scalable blood filtration device using inertial microfluidics
Mach, A. J., & Di Carlo, D. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22833 · Cited by 334
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Metadata
- Authors
- Yung, C. W., Fiering, J., Mueller, A. J., & Ingber, D. E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 9
- Pages
- 1171
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2032158729
- Cited by
- 196
- References
- 2
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromagnetic–microfluidic blood cleansing device. https://app.cochat.ai/papers/10.1039/b816986a
- The paper
- Yung, C. W., Fiering, J., Mueller, A. J., & Ingber, D. E. (2009). Micromagnetic–microfluidic blood cleansing device. Lab on a Chip. https://doi.org/10.1039/b816986a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.