The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Beating Poisson encapsulation statistics using close-packed ordering
Abstract
Loading drops with discrete objects, such as particles and cells, is often necessary when performing chemical and biological assays in microfluidic devices. However, random loading techniques are inefficient, yielding a majority of empty and unusable drops. We use deformable particles that are close packed to insert a controllable number of particles into every drop. This provides a simple, flexible means of efficiently encapsulating a controllable number of particles per drop.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Droplet barcoding for single-cell transcriptomics applied to embryonic stem cells
Klein, A. M., Mazutis, L., Akartuna, I., Tallapragada, N., Veres, A., Li, V., Peshkin, L., Weitz, D. A., & Kirschner, M. W. (2015) · Cell · doi:10.1016/j.cell.2015.04.044 · Cited by 3,356
“The flow of deformable hydrogels inside the chip can be synchronized due to their close packing and regular release, allowing nearly 100% hydrogel droplet occupancy (Abate et al. 2009).”
Self-citationMicrodroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Haplotyping germline and cancer genomes with high-throughput linked-read sequencing
Zheng, G. X. Y., Lau, B. T., Schnall-Levin, M., Jarosz, M., Bell, J. M., Hindson, C. M., Kyriazopoulou-Panagiotopoulou, S., Masquelier, D. A., Merrill, L., Terry, J. M., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3432 · Cited by 677
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
High-throughput single-cell ChIP-seq identifies heterogeneity of chromatin states in breast cancer
Grosselin, K., Durand, A., Marsolier, J., Poitou, A., Marangoni, E., Nemati, F., Dahmani, A., Lameiras, S., Reyal, F., Frenoy, O., et al. (2019) · Nature Genetics · doi:10.1038/s41588-019-0424-9 · Cited by 466
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Dripping and jetting in microfluidic multiphase flows applied to particle and fibre synthesis
Nunes, J. K., Tsai, S. S. H., Wan, J., & Stone, H. A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114002 · Cited by 406
Comparative Analysis of Droplet-Based Ultra-High-Throughput Single-Cell RNA-Seq Systems
Zhang, X., Li, T., Liu, F., Chen, Y., Yao, J., Li, Z., Huang, Y., & Wang, J. (2019) · Molecular Cell · doi:10.1016/j.molcel.2018.10.020 · Cited by 383
Recent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
Moragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Wang, J., Wang, J., & Han, J. (2011) · Small · doi:10.1002/smll.201001913 · Cited by 293
Single‐Cell Analysis Using Droplet Microfluidics
Matuła, K., Rivello, F., & Huck, W. T. S. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900188 · Cited by 277
Functional single-cell hybridoma screening using droplet-based microfluidics
Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204514109 · Cited by 276
Abseq: Ultrahigh-throughput single cell protein profiling with droplet microfluidic barcoding
Shahi, P., Kim, S. C., Haliburton, J. R., Gartner, Z. J., & Abate, A. R. (2017) · Scientific Reports · doi:10.1038/srep44447 · Cited by 259
Self-citationGérard, A., Woolfe, A., Mottet, G., Reichen, M., Castrillon, C., Menrath, V., Ellouze, S., Poitou, A., Doineau, R., Briseno-Roa, L., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0466-7 · Cited by 256
Droplet-based single cell RNAseq tools: a practical guide
Salomon, R., Kaczorowski, D., Valdes-Mora, F., Nordon, R. E., Neild, A., Farbehi, N., Bartonicek, N., & Gallego-Ortega, D. (2019) · Lab on a Chip · doi:10.1039/c8lc01239c · Cited by 109
Metadata
- Authors
- Abate, A. R., Chen, C.-H., Agresti, J. J., & Weitz, D. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 18
- Pages
- 2628
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2114385847
- Cited by
- 189
- References
- 1
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.