The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Abstract
Miniature high speed label-free cell analysis systems have yet to be developed, but have the potential to deliver fast, inexpensive and simple full blood cell analysis systems that could be used routinely in clinical practice. We demonstrate a microfluidic single cell impedance cytometer that performs a white blood cell differential count. The device consists of a microfluidic chip with micro-electrodes that measure the impedance of single cells at two frequencies. Human blood, treated with saponin/formic acid to lyse erythrocytes, flows through the device and a complete blood count is performed in a few minutes. Verification of cell dielectric parameters was performed by simultaneously measuring fluorescence from CD antibody-conjugated cells. This enabled direct correlation of impedance signals from individual cells with phenotype. Tests with patient samples showed 95% correlation against commercial (optical/Coulter) blood analysis equipment, demonstrating the potential clinical utility of the impedance microcytometer for a point-of-care blood analysis system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Single cell dielectric spectroscopy
Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/1/s10 · Cited by 445
Self-citationImpedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation
Cheung, K. C., Gawad, S., & Renaud, P. (2005) · Cytometry Part A · doi:10.1002/cyto.a.20141 · Cited by 438
THE ELECTRIC CAPACITY OF SUSPENSIONS WITH SPECIAL REFERENCE TO BLOOD
Fricke, H. (1925) · Journal of General Physiology · doi:10.1085/jgp.9.2.137 · Cited by 270
Hemolysis of human erythrocytes with saponin affects the membrane structure
Baumann, E., Stoya, G., Völkner, A., Richter, W., Lemke, C., & Linss, W. (2000) · Acta Histochemica · doi:10.1078/0065-1281-00534 · Cited by 181
Chwalek, M., Lalun, N., Bobichon, H., Plé, K., & Voutquenne‐Nazabadioko, L. (2006) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2006.05.004 · Cited by 152
Bead-based immunoassays using a micro-chip flow cytometer
Holmes, D., She, J. K., Roach, P. L., & Morgan, H. (2007) · Lab on a Chip · doi:10.1039/b707507n · Cited by 105
Self-citation
Cited by
Single-cell microfluidic impedance cytometry: a review
Sun, T., & Morgan, H. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0580-9 · Cited by 576
Self-citationContinuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
A review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Sheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
Dual-frequency impedance assays for intracellular components in microalgal cells
Tang, T., Liu, X., Yuan, Y., Kiya, R., Shen, Y., Zhang, T., Suzuki, K., Tanaka, Y., Li, M., Hosokawa, Y., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00721a · Cited by 26
Metadata
- Authors
- Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 20
- Pages
- 2881
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2091124606
- Cited by
- 408
- References
- 9
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.