CoChat

Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references

Wen, Hanjie, Carignan, Jean, Cloquet, Christophe, Zhu, Xiangkun, Zhang, Yuxu · 2010 · Journal of Analytical Atomic Spectrometry
Cited by 54

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We report the isotopic composition of five molybdenum (Mo) standard reference solutions and four fractions from one of these solutions eluted through anion resin column relative to a sixth reference solution. The reference solutions were National Institute of Standards and Technology (NIST) SRM 3134 (lot#891307), Johnson Matthey Specpure (JMC)-Mo Sie (lot #602332B), JMC-Mo Wen (lot#13989C), Merck (lot#170334), Sigma-Aldrich (lot#207306) and Prolabo. Measurements were conducted using Isoprobe multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS) at the Centre de Recherches Pétrographiques et Géochimiques (France) and Nu Plasma MC-ICP-MS at either the Ecole Normale Supérieure de Lyon (France) or the Laboratory of Isotope Geology in the Ministry of Land and Resources (China). The sample-standard bracketing method was employed to correct the mass bias for Mo isotopes during instrumental measurement. Except for the Merck Mo solution, all the Mo solutions were identical in isotopic composition within error. Although the JMC Mo solution has been used as the internal reference material by various groups, uncertainty may still occur with different lot numbers and availability might be limited. Here, we propose the NIST 3134 Mo solution as a new candidate for delta zero reference material, used for reporting Mo isotopic composition of natural samples. Isotopic compositions for four eluted fractions of the Sigma-Aldrich Mo solution were 2.18‰, 0.98‰, −1.10‰ and −1.95‰ for δ97/95Mo relative to the NIST Mo standard. These values span the range of reported isotopic compositions for natural terrestrial and experimental samples (approximately −0.5‰ to 1.6‰ for δ97/95Mo). We propose these eluted fractions to be used as a secondary reference for Mo isotope measurements. Mo solutions are available at CRPG upon request.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b921060a

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 54

Metadata

Authors
Wen, H., Carignan, J., Cloquet, C., Zhu, X., & Zhang, Y.
Venue
Journal of Analytical Atomic Spectrometry
Published
2010
Volume
25
Issue
5
Pages
716
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2115354012
Cited by
54
References
3
FWCI
4.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references. https://app.cochat.ai/papers/10.1039/b921060a
The paper
Wen, H., Carignan, J., Cloquet, C., Zhu, X., & Zhang, Y. (2010). Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/b921060a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.