The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Centrifugal microfluidics for biomedical applications
Abstract
The centrifugal microfluidic platform has been a focus of academic and industrial research efforts for almost 40 years. Primarily targeting biomedical applications, a range of assays have been adapted on the system; however, the platform has found limited commercial success as a research or clinical tool. Nonetheless, new developments in centrifugal microfluidic technologies have the potential to establish wide-spread utilization of the platform. This paper presents an in-depth review of the centrifugal microfluidic platform, while highlighting recent progress in the field and outlining the potential for future applications. An overview of centrifugal microfluidic technologies is presented, including descriptions of advantages of the platform as a microfluidic handling system and the principles behind centrifugal fluidic manipulation. The paper also discusses a history of significant centrifugal microfluidic platform developments with an explanation of the evolution of the platform as it pertains to academia and industry. Lastly, we review the few centrifugal microfluidic-based sample-to-answer analysis systems shown to date and examine the challenges to be tackled before the centrifugal platform can be more broadly accepted as a new diagnostic platform. In particular, fully integrated, easy to operate, inexpensive and accurate microfluidic tools in the area of in vitro nucleic acid diagnostics are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Self-citationMicrofabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
Self-citationThe centrifugal microfluidic Bio-Disk platform
Ducrée, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. V., & Zengerle, R. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s07 · Cited by 405
Principles of Bacterial Detection: Biosensors, Recognition Receptors and Microsystems
(2008) · Springer eBooks · doi:10.1007/978-0-387-75113-9 · Cited by 337
One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device
Cho, Y.-K., Lee, J.-G., Park, J.-M., Lee, B.-S., Lee, Y., & Ko, C. (2007) · Lab on a Chip · doi:10.1039/b616115d · Cited by 312
Self-citationA fully automated immunoassay from whole blood on a disc
Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C. (2009) · Lab on a Chip · doi:10.1039/b820321k · Cited by 302
Self-citationA Continuous-Flow Capillary Mixing Method to Monitor Reactions on the Microsecond Time Scale
Shastry, M. C. R., Luck, S. D., & Roder, H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77977-9 · Cited by 216
Honda, N., Lindberg, U., Andersson, P., Hoffmann, S., & Takei, H. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.053348 · Cited by 156
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
Self-citationMartínez‐Duarte, R., Gorkin, R. A., III, Abi‐Samra, K., & Madou, M. J. (2010) · Lab on a Chip · doi:10.1039/b925456k · Cited by 149
Self-citationSpinning Disk Platform for Microfluidic Digital Polymerase Chain Reaction
Sundberg, S. O., Wittwer, C. T., Gao, C., & Gale, B. K. (2010) · Analytical Chemistry · doi:10.1021/ac902398c · Cited by 146
A novel, compact disk-like centrifugal microfluidics system for cell lysis and sample homogenization
Kido, H., Mićić, M., Smith, D., Zoval, J. V., Norton, J., & Madou, M. J. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.03.015 · Cited by 130
Self-citationFully integrated whole blood testing by real-time absorption measurement on a centrifugal platform
Steigert, J., Grumann, M., Brenner, T., Riegger, L., Harter, J., Zengerle, R., & Ducrée, J. (2006) · Lab on a Chip · doi:10.1039/b607051p · Cited by 129
Siegrist, J., Gorkin, R. A., III, Bastien, M., Stewart, G., Peytavi, R., Kido, H., Bergeron, M. G., & Madou, M. J. (2009) · Lab on a Chip · doi:10.1039/b913219h · Cited by 114
Self-citationMicrofluidic Device for Rapid (<15 min) Automated Microarray Hybridization
Peytavi, R., Raymond, F., Gagné, D., Picard, F. J., Jia, G., Zoval, J. V., Madou, M. J., Boissinot, K., Boissinot, M., Bissonnette, L., et al. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052845 · Cited by 112
Self-citationParallel Nanoliter Microfluidic Analysis System
Andersson, P., Jesson, G., Kylberg, G., Ekstrand, G., & Thorsén, G. (2007) · Analytical Chemistry · doi:10.1021/ac061692y · Cited by 108
Invited Review Article: Review of centrifugal microfluidic and bio-optical disks
Nolte, D. D. (2009) · Review of Scientific Instruments · doi:10.1063/1.3236681 · Cited by 90
Automated microfluidic compact disc (CD) cultivation system of Caenorhabditis elegans
Kim, N., Dempsey, C. M., Zoval, J. V., Sze, J.-Y., & Madou, M. J. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.026 · Cited by 88
Self-citationA general method of isolating high molecular weight DNA from methanogenic archaea (archaebacteria)
Jarrell, K. F., Faguy, D. M., Hebert, A. M., & Kalmokoff, M. L. (1992) · Canadian Journal of Microbiology · doi:10.1139/m92-010 · Cited by 84
Sensitivity enhancement for colorimetric glucose assays on whole blood by on-chip beam-guidance
Grumann, M., Steigert, J., Riegger, L., Moser, I., Enderle, B., Riebeseel, K., Urban, G. A., Zengerle, R., & Ducrée, J. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8172-x · Cited by 77
Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics
Steigert, J., Grumann, M., Dube, M., Streule, W., Riegger, L., Brenner, T., Koltay, P., Mittmann, K., Zengerle, R., & Ducrée, J. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.01.031 · Cited by 54
Nucleic acid microarrays created in the double-spiral format on a circular microfluidic disk
Chen, H., Wang, L., & Li, P. C. H. (2008) · Lab on a Chip · doi:10.1039/b719846a · Cited by 46
Kim, N., Dempsey, C. M., Kuan, C.-J., Zoval, J. V., O’Rourke, E. J., Ruvkun, G., Madou, M. J., & Sze, J. Y. (2007) · Genetics · doi:10.1534/genetics.107.076901 · Cited by 42
Self-citationTaskova, R. M., Zorn, H., Krings, U., Bouws, H., & Berger, R. G. (2006) · Zeitschrift für Naturforschung C · doi:10.1515/znc-2006-5-608 · Cited by 35
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Metadata
- Authors
- Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 14
- Pages
- 1758
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2160727579
- Cited by
- 731
- References
- 27
- FWCI
- 23.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.