The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications
Open accessAbstract
Despite the rapid progress in optical imaging, most of the advanced microscopy modalities still require complex and costly set-ups that unfortunately limit their use beyond well equipped laboratories. In the meantime, microscopy in resource-limited settings has requirements significantly different from those encountered in advanced laboratories, and such imaging devices should be cost-effective, compact, light-weight and appropriately accurate and simple to be usable by minimally trained personnel. Furthermore, these portable microscopes should ideally be digitally integrated as part of a telemedicine network that connects various mobile health-care providers to a central laboratory or hospital. Toward this end, here we demonstrate a lensless on-chip microscope weighing approximately 46 grams with dimensions smaller than 4.2 cm x 4.2 cm x 5.8 cm that achieves sub-cellular resolution over a large field of view of approximately 24 mm(2). This compact and light-weight microscope is based on digital in-line holography and does not need any lenses, bulky optical/mechanical components or coherent sources such as lasers. Instead, it utilizes a simple light-emitting-diode (LED) and a compact opto-electronic sensor-array to record lensless holograms of the objects, which then permits rapid digital reconstruction of regular transmission or differential interference contrast (DIC) images of the objects. Because this lensless incoherent holographic microscope has orders-of-magnitude improved light collection efficiency and is very robust to mechanical misalignments it may offer a cost-effective tool especially for telemedicine applications involving various global health problems in resource limited settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
Developing optofluidic technology through the fusion of microfluidics and optics
Psaltis, D., Quake, S. R., & Yang, C. (2006) · Nature · doi:10.1038/nature05060 · Cited by 1,733
Pavani, S. R. P., Thompson, M. A., Biteen, J. S., Lord, S. J., Liu, N., Twieg, R. J., Piestun, R., & Moerner, W. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900245106 · Cited by 1,040
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Choi, W., Fang-Yen, C., Badizadegan, K., Oh, S., Lue, N., Dasari, R. R., & Feld, M. S. (2007) · Nature Methods · doi:10.1038/nmeth1078 · Cited by 955
Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena
Goda, K., Tsia, K. K., & Jalali, B. (2009) · Nature · doi:10.1038/nature07980 · Cited by 763
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Non-scanning motionless fluorescence three-dimensional holographic microscopy
Rosen, J., & Brooker, G. (2008) · Nature Photonics · doi:10.1038/nphoton.2007.300 · Cited by 424
In vivo fluorescence imaging with high-resolution microlenses
Barretto, R. P. J., Messerschmidt, B., & Schnitzer, M. J. (2009) · Nature Methods · doi:10.1038/nmeth.1339 · Cited by 274
Lensfree holographic imaging for on-chip cytometry and diagnostics
Seo, S., Su, T., Tseng, D. K., Erlinger, A., & Özcan, A. (2008) · Lab on a Chip · doi:10.1039/b813943a · Cited by 273
Self-citationWide field-of-view lens-free fluorescent imaging on a chip
Coskun, A. F., Su, T., & Özcan, A. (2010) · Lab on a Chip · doi:10.1039/b926561a · Cited by 93
Cited by
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,321
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationMicrofluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
Self-citation
Metadata
- Authors
- Mudanyali, O., Tseng, D., Oh, C., Isikman, S. O., Sencan, I., Bishara, W., Oztoprak, C., Seo, S., Khademhosseini, B., & Ozcan, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 11
- Pages
- 1417
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1990178988
- Cited by
- 488
- References
- 18
- FWCI
- 17.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.