Fluid-shear-stress-induced translocation of aquaporin-2 and reorganization of actin cytoskeleton in renal tubular epithelial cells
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In vivo, renal tubular epithelial cells are exposed to luminal fluid shear stress (FSS) and a transepithelial osmotic gradient. In this study, we used a simple collecting-duct-on-a-chip to investigate the role of an altered luminal microenvironment in the translocation of aquaporin-2 (AQP2) and the reorganization of actin cytoskeleton (F-actin) in primary cultured inner medullary collecting duct (IMCD) cells of rat kidney. Immunocytochemistry demonstrated that 3 h of exposure to luminal FSS at 1 dyn cm(-2) was sufficient to induce depolymerization of F-actin in those cells. We observed full actin depolymerization after 5 h exposure and substantial re-polymerization within 2 h of removing the luminal FSS, suggesting that the process is reversible and the fluidic environment regulates the reorganization of intracellular F-actin. We demonstrate that several factors (i.e., luminal FSS, hormonal stimulation, transepithelial osmotic gradient) collectively exert a profound effect on the AQP2 trafficking in the collecting ducts, which is associated with actin cytoskeletal reorganization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Aquaporins in the Kidney: From Molecules to Medicine
Nielsen, S., Frøkiær, J., Marples, D., Kwon, T.-H., Agre, P., & Knepper, M. A. (2002) · Physiological Reviews · doi:10.1152/physrev.00024.2001 · Cited by 1,251
Self-citationMicroscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Tzima, E. (2001) · The EMBO Journal · doi:10.1093/emboj/20.17.4639 · Cited by 569
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Self-citationHuh, D., Fujioka, H., Tung, Y.-C., Futai, N., Paine, R., Grotberg, J. B., & Takayama, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610868104 · Cited by 492
Paper-supported 3D cell culture for tissue-based bioassays
Derda, R., Laromaine, A., Mammoto, A., Tang, S. K. Y., Mammoto, T., Ingber, D. E., & Whitesides, G. M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910666106 · Cited by 423
Removal of the MDCK Cell Primary Cilium Abolishes Flow Sensing
Praetorius, H. A., & Spring, K. R. (2003) · Journal of Membrane Biology · doi:10.1007/s00232-002-1042-4 · Cited by 344
A PHYSIOLOGICAL VIEW OF THE PRIMARY CILIUM
Praetorius, H. A., & Spring, K. R. (2005) · Annual Review of Physiology · doi:10.1146/annurev.physiol.67.040403.101353 · Cited by 298
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
“To study polarized functions of various epithelial cells (e.g. intestine [47,48], lung [49], kidney [50,51], cornea [52]), for example, two PDMS cell-culture chambers were stacked and separated by a permeable synthetic membrane or ECM (Figure 2a).”
BackgroundKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Self-citationMicrofabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Kang, J. H., Krause, S., Tobin, H., Mammoto, A., Kanapathipillai, M., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40072c · Cited by 274
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
A disease model of diabetic nephropathy in a glomerulus-on-a-chip microdevice
Wang, L., Tao, T., Su, W., Yu, H., Yu, Y., & Qin, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00134g · Cited by 207
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
Shear stress-induced alteration of epithelial organization in human renal tubular cells
Maggiorani, D., Dissard, R., Belloy, M., Saulnier-Blache, J.-S., Casemayou, A., Ducasse, L., Grès, S., Bellière, J., Caubet, C., Bascands, J.-L., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131416 · Cited by 74
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Jiménez-Torres, J. A., Virumbrales-Muñoz, M., Sung, K. E., Lee, M. H., Abel, E. J., & Beebe, D. J. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.03.026 · Cited by 46
Metadata
- Authors
- Jang, K.-J., Cho, H. S., Kang, D. H., Bae, W. G., Kwon, T.-H., & Suh, K.-Y.
- Venue
- Integr. Biol.
- Publisher
- Oxford University Press (OUP)
- Published
- 2011
- Volume
- 3
- Issue
- 2
- Pages
- 134-141
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W1995371184
- Cited by
- 177
- References
- 24
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.