Breast on-a-chip: mimicry of the channeling system of the breast for development of theranostics
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Improved detection and therapy of breast neoplasia might benefit from nanodevices traveling inside mammary ducts. However, the decreasing size of branched mammary ducts prevents access to remote areas of the ductal system using a pressure-driven fluid-based approach. Magnetic field guidance of superparamagnetic submicron particles (SMPs) in a stationary fluid might provide a possible alternative but it is critical to first reproduce the breast ductal system to assess the use of such devices for future therapeutic & diagnostic ("theranostic") purposes. Here we describe the engineering of a portion of a breast ductal system using polydimethylsiloxane (PDMS) microfluidic channels with a total volume of 0.09 μl. A magnet was used to move superparamagnetic/fluorescent SMPs through a static fluid inside the microchannels. Non-neoplastic mammary epithelial S1 cells developed basoapical polarity as a flat monolayer on the PDMS surface when cultured in the presence of laminin 111, and incubation with SMPs did not result in detectable toxicity. Cells could not withstand the fluid pressure if microinjected directly in completed channels. Whereas, they readily covered laminin 111-coated PDMS surfaces when cultured in U-shaped "hemichannels" before completing the channels. This breast-on-chip model represents a critical step towards the mimicry of the tree-like ductal system of the breast for further testing and targeting of SMPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Wang, X., Sun, L., Maffini, M. V., Soto, A., Sonnenschein, C., & Kaplan, D. L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.118 · Cited by 120
Cited by
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
A microengineered pathophysiological model of early-stage breast cancer
Choi, Y., Hyun, E., Seo, J., Blundell, C., Kim, H. C., Lee, E., Lee, S. H., Moon, A., Moon, W. K., & Huh, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00514k · Cited by 222
Yoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Microfluidic model of ductal carcinoma in situ with 3D, organotypic structure
Bischel, L. L., Beebe, D. J., & Sung, K. E. (2015) · BMC Cancer · doi:10.1186/s12885-015-1007-5 · Cited by 110
“Complementary to recent in vitro mammary duct models which focus on studying the initiation of mammary tumors within the mammary duct from small groups of cancer cells [35,37], we have used a high number of DCIS cells in order to mimic a more advanced stage of DCIS, similar to the MIND mouse model that has been previo…”
BackgroundResultDisease-on-a-chip: mimicry of tumor growth in mammary ducts
Vidi, P.-A., Maleki, T., Ochoa, M., Wang, L., Clark, S. M., Leary, J. F., & Lelièvre, S. A. (2014) · Lab Chip · doi:10.1039/c3lc50819f · Cited by 71
Self-citation
Metadata
- Authors
- Grafton, M. M. G., Wang, L., Vidi, P.-A., Leary, J., & Lelièvre, S. A.
- Venue
- Integrative Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 2011
- Volume
- 3
- Issue
- 4
- Pages
- 451
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W1977761310
- Cited by
- 61
- References
- 2
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.