Combination of fluid and solid mechanical stresses contribute to cell death and detachment in a microfluidic alveolar model
The DOI matches its Crossref record; 33 of the 35 references it cites were found in a registry or an index.
Abstract
Studies using this micro-system demonstrated significant morphological differences between alveolar epithelial cells (transformed human alveolar epithelial cell line, A549 and primary murine alveolar epithelial cells, AECs) exposed to combination of solid mechanical and surface-tension stresses (cyclic propagation of air-liquid interface and wall stretch) compared to cell populations exposed solely to cyclic stretch. We have also measured significant differences in both cell death and cell detachment rates in cell monolayers experiencing combination of stresses. This research describes new tools for studying the combined effects of fluid mechanical and solid mechanical stress on alveolar cells. It also highlights the role that surface tension forces may play in the development of clinical pathology, especially under conditions of surfactant dysfunction. The results support the need for further research and improved understanding on techniques to reduce and eliminate fluid stresses in clinical settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [118]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [118]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
The motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313
ESTEBAN, A., ANZUETO, A., ALÍA, I., GORDO, F., APEZTEGUÍA, C., PÁLIZAS, F., CIDE, D., GOLDWASER, R., SOTO, L., BUGEDO, G., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9902018 · Cited by 780
Aerosolized Surfactant in Adults with Sepsis-Induced Acute Respiratory Distress Syndrome
Anzueto, A., Baughman, R. P., Guntupalli, K. K., Weg, J. G., Wiedemann, H. P., Raventós, A. A., Lemaire, F., Long, W., Zaccardelli, D. S., & Pattishall, E. N. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605303342201 · Cited by 594
Huh, D., Fujioka, H., Tung, Y.-C., Futai, N., Paine, R., Grotberg, J. B., & Takayama, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610868104 · Cited by 492
Self-citationB IOFLUID M ECHANICS IN F LEXIBLE T UBES
Grotberg, J. B., & Jensen, O. E. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121918 · Cited by 455
Self-citationStretch induces cytokine release by alveolar epithelial cells in vitro
Vlahakis, N. E., Schroeder, M. A., Limper, A. H., & Hubmayr, R. D. (1999) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1999.277.1.l167 · Cited by 389
Bilek, A. M., Dee, K. C., & Gaver, D. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00764.2002 · Cited by 354
TSCHUMPERLIN, D. J., OSWARI, J., & MARGULIES, A. S. S. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9807003 · Cited by 347
Research works printed but not linked: 5
- Tschumperlin, 1998, Am. J. Physiol., 275, L1173
- Tavana, 2009, Lab. Med. (Chicago, IL, U. S.), 40, 203
- E. R. Weibel , Morphology of the Lung, Springer Verlag, Berlin, 1963
- Zamankhan, 2010, Phys. Fluids
- Tai, 2010, J. Fluid Mech.
Cited by
Items 101–200 of 221
Saberi‐Bosari, S., Huayta, J., & San‐Miguel, A. (2018) · Lab on a Chip · doi:10.1039/c8lc00655e · Cited by 34
Engineering cell heterogeneity into organs-on-a-chip
Mertz, D. R., Ahmed, T., & Takayama, S. (2018) · Lab on a Chip · doi:10.1039/c8lc00413g · Cited by 33
Self-citationTranslating advances in organ‐on‐a‐chip technology for supporting organs
Ashammakhi, N. A., ELKHAMMAS, E. A., & Hasan, A. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34292 · Cited by 34
Zhao, Q., Cole, T., Zhang, Y., & Tang, S. (2021) · Micromachines · doi:10.3390/mi12070765 · Cited by 33
“introduced a microfluidic alveolar platform with cultured human epithelial cells to investigate ventilator-induced lung injury caused by fluid and mechanical stresses [60].”
BackgroundOrgan‐On‐A‐Chip Devices: Technology Progress and Challenges
Obeid, P. J., Yammine, P., El‐Nakat, H., Kassab, R., Tannous, T., Nasr, Z., Maarawi, T., Dahdah, N., Safadi, A. E., Mansour, A., et al. (2024) · ChemBioChem · doi:10.1002/cbic.202400580 · Cited by 39
Benam, K. H., Königshoff, M., & Eickelberg, O. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201709-1795pp · Cited by 30
Human lung-on-chips: Advanced systems for respiratory virus models and assessment of immune response
Saygılı, E., Yıldız-Ozturk, E., Green, M. J., Ghaemmaghami, A. M., & Yeşil-Çeliktaş, Ö. (2021) · Biomicrofluidics · doi:10.1063/5.0038924 · Cited by 29
In situ enhancement of pulmonary surfactant function using temporary flow reversal
Glindmeyer, H. W., Smith, B. J., & Gaver, D. P. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00643.2011 · Cited by 27
“For example, the reopening of obstructed airways, which is necessary for allowing gas transport to the alveoli, may cause cell necrosis (3, 8, 13, 22, 23, 38), increased permeability (29), and pulmonary surfactant dysfunction that can have a long-term consequence to pulmonary function (7, 9).”
BackgroundIn vitro-ex vivo model systems for nanosafety assessment
Wick, P., Chortarea, S., Guenat, O. T., Roesslein, M., Stucki, J. D., Hirn, S., Petri‐Fink, A., & Rothen‐Rutishauser, B. (2015) · European Journal of Nanomedicine · doi:10.1515/ejnm-2014-0049 · Cited by 28
Kurth, F., Györvary, E., Heub, S., Ledroit, D., Paoletti, S., Renggli, K., Revol, V., Verhulsel, M., Weder, G., & Loizeau, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00003-6 · Cited by 31
Pressure measurement methods in microchannels: advances and applications
Shen, F., Ai, M., Li, Z., Lu, X., Pang, Y., & Liu, Z. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02435-w · Cited by 29
Tackling Current Biomedical Challenges With Frontier Biofabrication and Organ-On-A-Chip Technologies
Celikkin, N., Presutti, D., Maiullari, F., Fornetti, E., Agarwal, T., Paradiso, A., Volpi, M., Święszkowski, W., Bearzi, C., Barbetta, A., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.732130 · Cited by 26
“…into organ-on-a-chip-based systems, including liver (Nakao et al., 2011), kidney (Jang and Suh, 2010), intestine (Kim et al., 2016), lung (Douville et al., 2011), heart (Grosberg et al., 2011), muscle (Grosberg et al., 2012), vessel (Song and Munn, 2011), and bone marrow (Torisawa et…”
BackgroundPark, S., Newton, J. D., Hidjir, T., & Young, E. W. K. (2023) · Lab on a Chip · doi:10.1039/d3lc00259d · Cited by 28
Interaction between lung cancer cell and myofibroblast influenced by cyclic tensile strain
Huang, J.-W., Pan, H.-J., Yao, W.-Y., Tsao, Y.-W., Liao, W.-Y., Wu, C.-W., Tung, Y.-C., & Lee, C.-H. (2013) · Lab on a Chip · doi:10.1039/c2lc41050h · Cited by 24
Self-citationThree-dimensional models of the lung: past, present and future: a mini review
Sen, C., Freund, D., & Gomperts, B. N. (2022) · Biochemical Society Transactions · doi:10.1042/bst20190569 · Cited by 29
Viola, H., Chang, J. J., Grunwell, J. R., Hecker, L., Tirouvanziam, R. M., Grotberg, J. B., & Takayama, S. (2019) · APL Bioengineering · doi:10.1063/1.5111549 · Cited by 26
Self-citationReview of microfluidic cell culture devices for the control of gaseous microenvironments in vitro
Wu, H., Lee, T.-A., Ko, P.-L., Chiang, H.-J., Peng, C.-C., & Tung, Y. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aaa993 · Cited by 24
Self-citationInduced pluripotent stem cells for treating cystic fibrosis: State of the science
Pollard, B. S., & Pollard, H. B. (2018) · Pediatric Pulmonology · doi:10.1002/ppul.24118 · Cited by 23
“For example, it has been possible to mimic what might be happening in emphysema, where wall stresses might be great,(107) or ventilator-induced lung injury, where flow and stretch conditions can vary profoundly from normal states.(108) In pre“lung on a chip” era studies on cyclic stretch effects on lung cells, it was”
BackgroundRecent Advances of Biologically Inspired 3D Microfluidic Hydrogel Cell Culture Systems
Ertl, P. (2015) · Cell Biology & Cell Metabolism · doi:10.24966/cbcm-1943/100005 · Cited by 25
“For some organs such as the heart, lungs or arteries, there is a repetition in stretching and straining movements that can also be mimicked in microfluidic devices by integrating flexible membranes [87] or by combining sold and fluid mechanical stress [88].”
BackgroundShukr, R. F., Qader, H. A., Qader, I. B., Ameen, S. S. M., & Omer, K. M. (2025) · Chemical Papers · doi:10.1007/s11696-025-04301-3 · Cited by 26
“An alveolar model was constructed by Douville et al .”
Lu, J.-C., Liao, W.-H., & Tung, Y.-C. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075006 · Cited by 22
Self-citationLin, C.-H., Wang, C., Chen, Y., Peng, C., Liao, W., & Tung, Y. (2016) · Scientific Reports · doi:10.1038/srep36425 · Cited by 22
Self-citationMicrofluidics for mechanobiology of model organisms
Kim, A. A., Nekimken, A. L., Fechner, S., O’Brien, L. E., & Pruitt, B. L. (2018) · Methods in cell biology · doi:10.1016/bs.mcb.2018.05.010 · Cited by 23
“, 2009), compression (Guo, Park, & Ma, 2012; Kim, Kang, Park, Yoon, & Park, 2007), and tension (Douville et al., 2011; Gossett et al., 2012) for a range of biological applications Kim et al.”
BackgroundHe, J., Chen, W., Deng, S., Xie, L., Feng, J., Geng, J., Jiang, D., Dai, H., & Wang, C. (2017) · RSC Advances · doi:10.1039/c7ra06752f · Cited by 20
Respiratory Physiology on a Chip
Mahto, S. K., Tenenbaum‐Katan, J., & Sznitman, J. (2012) · Scientifica · doi:10.6064/2012/364054 · Cited by 20
Magnetic microboats for floating, stiffness tunable, air–liquid interface epithelial cultures
Chandrasekaran, A., Kouthouridis, S., Lee, W., Lin, N., Ma, Z., Turner, M. J., Hanrahan, J. W., & Moraes, C. (2019) · Lab on a Chip · doi:10.1039/c9lc00267g · Cited by 20
Three-Dimensional Cell Cultures as a Research Platform in Lung Diseases and COVID-19
da Costa, F. A. D. S., Soares, M. R., Malagutti-Ferreira, M. J., da Silva, G. R., Lívero, F. A. D. R., & Ribeiro‐Paes, J. T. (2021) · Tissue Engineering and Regenerative Medicine · doi:10.1007/s13770-021-00348-x · Cited by 21
Frampton, J. P., Fan, Z., Simon, A. B., Chen, D., Deng, C. X., & Takayama, S. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203321 · Cited by 19
Self-citationGabela-Zuniga, B., Shukla, V. C., Bobba, C. M., Higuita‐Castro, N., Powell, H. M., Englert, J. A., & Ghadiali, S. N. (2024) · Lab on a Chip · doi:10.1039/d4lc00143e · Cited by 18
Gao, W., Kanagarajah, K. R., Graham, E. C., Soon, K., Veres, T., Moraes, T. J., Bear, C. E., Veldhuizen, R. A. W., Wong, A. P., & Günther, A. (2024) · Small · doi:10.1002/smll.202309270 · Cited by 19
Multiarray Cell Stretching Platform for High-Magnification Real-Time Imaging
Huang, Y., Nguyen, N., Lok, K. S., Lee, P. P. F., Su, M., Wu, M., Kocgozlu, L., & Ladoux, B. (2013) · Nanomedicine · doi:10.2217/nnm.13.45 · Cited by 17
“It showed that a combination of fluid and solid mechanical stresses contribute to cell death and detachment of alveolar epithelial cells [22].”
Lung-on-chip microdevices to foster pulmonary drug discovery
Sisodia, Y., Shah, K., Sayyed, A. A., Jain, M., Ali, S. A., Gondaliya, P., Kalia, K., & Tekade, R. K. (2022) · Biomaterials Science · doi:10.1039/d2bm00951j · Cited by 17
Options for modeling the respiratory system: inserts, scaffolds and microfluidic chips
Sedláková, V., Kloučková, M., Garlíková, Z., Vašíčková, K., Jaroš, J., Kandra, M., Kotasová, H., & Hampl, A. (2019) · Drug Discovery Today · doi:10.1016/j.drudis.2019.03.006 · Cited by 17
Biomimetics of fetal alveolar flow phenomena using microfluidics
Tenenbaum‐Katan, J., Fishler, R., Rothen‐Rutishauser, B., & Sznitman, J. (2015) · Biomicrofluidics · doi:10.1063/1.4908269 · Cited by 16
Precise manipulation of cell behaviors on surfaces for construction of tissue/organs
Zheng, W., & Jiang, X. (2014) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2014.08.026 · Cited by 16
Vascularized Lower Respiratory-Physiology-On-A-Chip
Nam, H., Choi, Y., & Jang, J. (2020) · Applied Sciences · doi:10.3390/app10030900 · Cited by 16
“Fibronectin A549, primary murine alveolar epithelial cells Porous membrane sandwiched microchip, surface tension forces [37]”
BackgroundCells and Organs on Chip—A Revolutionary Platform for Biomedicine
Joshi, P. N. (2016) · InTech eBooks · doi:10.5772/64102 · Cited by 18
Steady displacement of long gas bubbles in channels and tubes filled by a Bingham fluid
Zamankhan, P., Takayama, S., & Grotberg, J. B. (2018) · Physical Review Fluids · doi:10.1103/physrevfluids.3.013302 · Cited by 15
Self-citationWu, C., Lu, J.-C., Liu, M.-C., & Tung, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc40436b · Cited by 15
Self-citationOrganomimetic microsystems technologies
Park, J., Kim, K. B., Lee, J., Kim, H. C., & Huh, D. (2012) · Biomedical Engineering Letters · doi:10.1007/s13534-012-0059-6 · Cited by 14
“Withdrawal of fluid from the actuation chamber results in the deformation of the intervening membrane and fluid motion to reproduce pathological mechanical forces generated by cyclic wall stretch and propagation of an airliquid interface during mechanical ventilation [14].”
BackgroundBioinspired Engineering of Organ-on-Chip Devices
Wang, L., Li, Z., Xu, C., & Qin, J. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-9791-2_13 · Cited by 14
Body-on-a-Chip: Regenerative Medicine for Personalized Medicine
Skardal, A., Shupe, T. D., & Atala, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-809880-6.00044-8 · Cited by 17
Taş, S., Rehnberg, E., Bölükbas, D. A., Beech, J. P., Kazado, L. N., Svenningsson, I., Arvidsson, M., Sandberg, A., Dahlgren, K. A., Edthofer, A., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.07.02.450873 · Cited by 15
A microdevice for parallelized pulmonary permeability studies
Bol, L., Galas, J.-C., Hillaireau, H., Potier, I. L., Nicolas, V., Haghiri‐Gosnet, A., Fattal, E., & Taverna, M. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9831-3 · Cited by 13
“…et al. 2008), renal (Baudoin et al. 2007), vascular (Shao et al. 2010; Yeon et al. 2012), blood-brain barrier (Booth and Kim 2012; Prabhakarpandian et al. 2012), airways (Douville et al. 2011; Huh et al. 2007; Tavana et al. 2011) and alveolar-blood barrier (Huh et al. 2010) have been described.”
BackgroundSplitting of a two-dimensional liquid plug at an airway bifurcation
Vaughan, B. L., & Grotberg, J. B. (2016) · Journal of Fluid Mechanics · doi:10.1017/jfm.2016.106 · Cited by 13
Self-citationJahagirdar, D., Bangde, P. S., Jain, R. D., & Dandekar, P. P. (2021) · Biotechnology Journal · doi:10.1002/biot.202100154 · Cited by 13
Higuita‐Castro, N., Shukla, V. C., Mihai, C., & Ghadiali, S. N. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1693-4 · Cited by 13
Stereolithography‐Based Polymer Additive Manufacturing Process for Microfluidics Devices
Biswas, A., Singh, A. K., & Das, D. (2024) · Wiley eBooks · doi:10.1002/9781394238316.ch15 · Cited by 16
Artificial airways for the study of respiratory disease
Swindle, E. J., & Davies, D. E. (2011) · Expert Review of Respiratory Medicine · doi:10.1586/ers.11.78 · Cited by 11
Chernokal, B., Gonyea, C. R., & Gleghorn, J. P. (2023) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-26625-6_3 · Cited by 13
Chen, Y., Peng, C., Cheng, Y.-J., Wu, J., & Tung, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4829775 · Cited by 11
Self-citationNof, E., Artzy‐Schnirman, A., Bhardwaj, S., Sabatan, H., Waisman, D., Hochwald, O., Gruber, M., Borenstein‐Levin, L., & Sznitman, J. (2021) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10271 · Cited by 13
Chang, S.-H., Ko, P., Liao, W., Peng, C., & Tung, Y. (2021) · Micromachines · doi:10.3390/mi12040406 · Cited by 10
“To investigate how the combination of fluid and solid stresses commonly found in alveoli affects the alveolar epithelial cells, a novel multiple-layer microfluidic device simulating the in vivo physical microenvironments was also constructed in the previous study [21].”
Self-citationMicrophysiological models of human organs: A case study on microengineered lung-on-a-chip systems
Seo, J., & Huh, D. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00007-4 · Cited by 10
Lung-on-a-chip platforms for modeling disease pathogenesis
Dellaquila, A., Thomée, E., McMillan, A. H., & Lesher‐Pérez, S. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00004-8 · Cited by 12
From microchannels to microphysiological systems: Development of application specific devices
Yu, J., Lim, J., Choi, M., Chung, M., & Jeon, N. L. (2018) · Microelectronic Engineering · doi:10.1016/j.mee.2018.10.004 · Cited by 9
Lung-on-a-chip: From design principles to disease applications
Qiu, Y. L., & Hu, G. (2025) · Biomicrofluidics · doi:10.1063/5.0257908 · Cited by 8
Xie, S., Gardeniers, H. J. G. E., & Lüttge, R. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aabf7e · Cited by 8
Novel three-dimensional biochip pulmonary sarcoidosis model
Calcagno, T., Zhang, C., Tian, R., Ebrahimi, B., & Mirsaeidi, M. S. (2021) · PLoS ONE · doi:10.1371/journal.pone.0245805 · Cited by 8
ULTRATHIN, HYPERELASTIC PDMS NANO MEMBRANE : FABRICATION AND CHARACTERIZATION
Ryoo, J., Jeong, G. S., Kang, E., & Lee, S. H. (2011) · Cited by 7
Biological Applications of Microfluidics System
Solanki, S., & Pandey, C. M. (2016) · Springer eBooks · doi:10.1007/978-3-319-40036-5_8 · Cited by 8
Organ-on-Chip Devices Toward Applications in Drug Development and Screening
Uhl, C. G., Shi, W., & Liu, Y. (2018) · Journal of Medical Devices · doi:10.1115/1.4040272 · Cited by 7
Microfluidics: Organ-on-a-chip
Aghamiri, S., Rabiee, N., Ahmadi, S., Rabiee, M., Bagherzadeh, M., & Karimi, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818791-3.00001-2 · Cited by 7
Microfluidics “lab‐on‐a‐chip” system for food chemical hazard detection
Xu, J. (2014) · Wiley eBooks · doi:10.1002/9781118488553.ch9 · Cited by 6
Tissue engineered organoids for neural network modelling
Roach, P., Köse-Dunn, M. J., & Fricker, R. A. (2017) · Advances in Tissue Engineering & Regenerative Medicine Open Access · doi:10.15406/atroa.2017.03.00066 · Cited by 6
“Amongst these are intestine [3], lung [4-6] and kidney [7,8], to name a few.”
BackgroundNext‐generation preclinical models of lung development, physiology and disease
Jozani, K. A., Kouthouridis, S., Hirota, J. A., & Zhang, B. (2022) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.24581 · Cited by 6
Wang, C., Liu, S., Li, C., Wang, Z., Ming, R., & Huang, L. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c15125 · Cited by 5
Iriondo, C., Koornneef, S., Skarp, K., Kempen, M. B., Munck, A. B., & Rottier, R. J. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c01322 · Cited by 8
Biofabrication of phenotypic pulmonary fibrosis assays
Yamanishi, C. D., Robinson, S., & Takayama, S. (2019) · Biofabrication · doi:10.1088/1758-5090/ab2286 · Cited by 5
Self-citationMikroakışkan Çiplere Kök Hücre ve Doku Mühendisliği Perspektifinden Bakış
Torkay, G., & Bal‐Öztürk, A. (2024) · Journal of Polytechnic · doi:10.2339/politeknik.1094010 · Cited by 5
Prediction of shear stress imposed on alveolar epithelium of healthy and diseased lungs
Livanos, A., Bouchoris, K., Aslani, Κ.-E., Gourgoulianis, K. I., & Bontozoglou, V. (2024) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-024-01889-5 · Cited by 4
Lin, T.-R., Yeh, S.-L., Peng, C., Liao, W., & Tung, Y. (2019) · Micromachines · doi:10.3390/mi10060400 · Cited by 4
“5 mm) with a designated volume and flow rate using a computer-controlled syringe pump [12].”
MethodSelf-citationNalayanda, D. D., Fulton, W. B., Wang, T., & Abdullah, F. (2013) · Integrative Biology · doi:10.1039/c3ib40037a · Cited by 4
Jafarzadeh, N., & Niroomand-Oscuii, H. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4694 · Cited by 4
The Development of Controllable Magnetic Driven Microphysiological System
Yang, J., Chen, Y., Ho, P.-Y., Jiang, L., Hsieh, K. Y., Cheng, S.-J., Lin, K.-C., Lu, H.-E., Chiu, H., Lin, S., et al. (2019) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2019.00275 · Cited by 4
Brain-on-a-chip integrated neuronal networks
Xie, S. (2016) · doi:10.3990/1.9789036542104 · Cited by 6
Investigation of tumour environments through advancements in microtechnology and nanotechnology
Liu, Z., Fan, Y. L., Cui, M., Wang, X., & Zhao, P. (2024) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2024.117230 · Cited by 4
Zhang, X., Su, L., & Pan, P. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13020346 · Cited by 3
“…on the occurrence and development of VILI using lung organoids, its influence on multiple organs in the body, gas exchange, and biomarkers related to VILI recognition is still very limited [86,93], which may be partially due to the lack of optimization of air–liquid matching in the organoid.”
BackgroundA micro lung chip to assess air pollutant effects
Noh, S., & Kim, H. (2017) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2017.7863452 · Cited by 3
“Dynamic models [7-10] incorporated micro airways to mimic air flows, representing closer to real exposure.”
BackgroundDesigner substrates and devices for mechanobiology study
Xi, W., Delacour, D., & Ladoux, B. (2020) · Journal of Semiconductors · doi:10.1088/1674-4926/41/4/041607 · Cited by 4
Ha, L., Jang, K., & Suh, K. Y. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737593-00019 · Cited by 3
Models of Surfactant Replacement Therapy in Neonatal Lungs
Combs, H., & Tavana, H. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4069657 · Cited by 2
Zhang, J., Zhou, J., Wang, Y., Yang, Y., Yue, T., & Chang, C. (2025) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2025.100415 · Cited by 2
3D modeling of the lung in health and disease
Surolia, R., Dsouza, K. G., & Antony, V. B. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824064-9.00016-2 · Cited by 3
Christwardana, M., Suedy, S. W. A., & Harmoko, U. (2024) · Eksergi · doi:10.31315/e.v21i2.11960 · Cited by 2
Wang, S., Lee, C., Shen, K., Tseng, F., & Wei, P. (2015) · RSC Advances · doi:10.1039/c5ra18801f · Cited by 2
Wagner, D. E., Uhl, F. E., Königshoff, M., & Weiss, D. J. (2015) · Stem cell biology and regenerative medicine · doi:10.1007/978-3-319-16232-4_8 · Cited by 2
Hydrodynamic nonadhesive cell retention in a microfluidic circuit for stressless suspension culture
Naito, T., Kaji, N., Tokeshi, M., Kubo, T., Baba, Y., & Otsuka, K. (2015) · Analytical Methods · doi:10.1039/c5ay00485c · Cited by 2
Microfluidic Approaches Toward Pulmonary Tissue Constructs
White, J. B. R., Douville, N. J., Moraes, C., Grotberg, J. B., & Takayama, S. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-3459-1.00010-7 · Cited by 2
Self-citationToward a Reasoned Classification of Diseases Using Physico-Chemical Based Phenotypes
Schwartz, L. H., Lafitte, O. D., & Moreira, J. D. V. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00094 · Cited by 3
Poojary, B. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_20 · Cited by 2
Viola, H., Chen, L.-H., Jo, S., Washington, K., Selva, C., Li, A., Feng, D., Giacalone, V. D., Stephenson, S. T., Cottrill, K. A., et al. (2025) · APL Bioengineering · doi:10.1063/5.0220367 · Cited by 1
Self-citationRespiratory Organ‐on‐a‐Chip for Disease Modeling: From Architecture to Functional Integration
Hu, J., Tang, Y., Liu, S., Xu, T., & Liu, Q. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505908 · Cited by 2
Acellular Lung Scaffolds in Lung Bioengineering
Wagner, D. E., Uhl, F. E., & Weiss, D. J. (2015) · Stem cell biology and regenerative medicine · doi:10.1007/978-3-319-21082-7_18 · Cited by 1
Colvin, K. L., & Yeager, M. E. (2015) · Frontiers in Pediatrics · doi:10.3389/fped.2015.00045 · Cited by 1
Takayama, S., White, J. B. R., & Zhang, C. (2014) · CRC Press eBooks · doi:10.1201/b16781-4 · Cited by 1
Self-citationBiopolymers for In Vitro Tissue Model Biofabrication
Skardal, A. (2016) · CRC Press eBooks · doi:10.1201/9781315368863-7 · Cited by 2
Microfluidics-Based Organ-on-a-Chip for Cell Biology Studies
Joseph, X., Megha, K. B., Arathi, A., Reshma, S. C., Amir, S., & Mohanan, P. V. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_3 · Cited by 1
Primary cell culture for organ-on-a-chip
Hegde, M., Girisa, S., & Harsha, C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00012-7 · Cited by 1
Body-on-a-chip: three-dimensional engineered tissue models
Shupe, T. D., Skardal, A., & Atala, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818422-6.00078-2 · Cited by 1
Metadata
- Authors
- Douville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Grotberg, James B.
- Takayama, Shuichi
- ORCID
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 4
- Pages
- 609-619
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2155681477
- Semantic Scholar
- b0900d1615e814b7d5d9eb49f6fd6cdc5319db66
- Cited by
- 216
- References
- 35
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 15 · 2023: 7 · 2022: 12 · 2021: 16 · 2020: 13 · 2019: 17 · 2018: 20 · 2017: 15 · 2016: 17 · 2015: 15 · 2014: 15 · 2013: 20 · 2012: 14
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL-084370, R01HL085156, F30HL095333, R01HL084370, HL 85156)
- National Institute of General Medical Sciences (T 32 GM07863, T32GM007863)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- alveolar epithelial cells, surface tension, cyclic strain, air-liquid interface, cell death, cell detachment, surfactant dysfunction, A549 cells
- MeSH terms
- Animals, Biomechanical Phenomena, Cell Adhesion, Cell Line, Transformed, Humans, Models, Biological, Pulmonary Alveoli, Stress, Mechanical, Surface Tension, Cell Death, Respiratory Mucosa, Microfluidic Analytical Techniques, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.