Combination of fluid and solid mechanical stresses contribute to cell death and detachment in a microfluidic alveolar model
The DOI matches its Crossref record; 33 of the 35 references it cites were found in a registry or an index.
Abstract
Studies using this micro-system demonstrated significant morphological differences between alveolar epithelial cells (transformed human alveolar epithelial cell line, A549 and primary murine alveolar epithelial cells, AECs) exposed to combination of solid mechanical and surface-tension stresses (cyclic propagation of air-liquid interface and wall stretch) compared to cell populations exposed solely to cyclic stretch. We have also measured significant differences in both cell death and cell detachment rates in cell monolayers experiencing combination of stresses. This research describes new tools for studying the combined effects of fluid mechanical and solid mechanical stress on alveolar cells. It also highlights the role that surface tension forces may play in the development of clinical pathology, especially under conditions of surfactant dysfunction. The results support the need for further research and improved understanding on techniques to reduce and eliminate fluid stresses in clinical settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [118]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [118]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
The motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313
ESTEBAN, A., ANZUETO, A., ALÍA, I., GORDO, F., APEZTEGUÍA, C., PÁLIZAS, F., CIDE, D., GOLDWASER, R., SOTO, L., BUGEDO, G., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9902018 · Cited by 780
Aerosolized Surfactant in Adults with Sepsis-Induced Acute Respiratory Distress Syndrome
Anzueto, A., Baughman, R. P., Guntupalli, K. K., Weg, J. G., Wiedemann, H. P., Raventós, A. A., Lemaire, F., Long, W., Zaccardelli, D. S., & Pattishall, E. N. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605303342201 · Cited by 594
Huh, D., Fujioka, H., Tung, Y.-C., Futai, N., Paine, R., Grotberg, J. B., & Takayama, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610868104 · Cited by 492
Self-citationB IOFLUID M ECHANICS IN F LEXIBLE T UBES
Grotberg, J. B., & Jensen, O. E. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121918 · Cited by 455
Self-citationStretch induces cytokine release by alveolar epithelial cells in vitro
Vlahakis, N. E., Schroeder, M. A., Limper, A. H., & Hubmayr, R. D. (1999) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1999.277.1.l167 · Cited by 389
Bilek, A. M., Dee, K. C., & Gaver, D. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00764.2002 · Cited by 354
TSCHUMPERLIN, D. J., OSWARI, J., & MARGULIES, A. S. S. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9807003 · Cited by 347
Research works printed but not linked: 5
- Tschumperlin, 1998, Am. J. Physiol., 275, L1173
- Tavana, 2009, Lab. Med. (Chicago, IL, U. S.), 40, 203
- E. R. Weibel , Morphology of the Lung, Springer Verlag, Berlin, 1963
- Zamankhan, 2010, Phys. Fluids
- Tai, 2010, J. Fluid Mech.
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“In several more complex devices, additional pneumatic channels were built into the devices, and cyclic wall stretching paired with fluid dynamics in the fluid channel can provide cues to the cells that resemble the mechanics of breathing [40,41].”
BackgroundA lung-on-a-chip array with an integrated bio-inspired respiration mechanism
Stucki, A. O., Stucki, J. D., Hall, S. R. R., Felder, M., Mermoud, Y., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c4lc01252f · Cited by 410
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
“[159], two different alveolar epithelial cells (transformed human alveolar epithelial cell line (A549) and primary murine alveolar epithelial cells (AECs)) separated by a PDMS thin membrane were exposed to a combination of surface tension and solid mechanical stresses.”
BackgroundOrgan-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
“To recreate the complexity of the human lung's structure, the use of 3D microfluidic systems that can introduce fluid and solid mechanical forces [110] is essential to imitate the human alveoli environment.”
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
“Certain enhancements have been made to single cell culture models, such as microfluidics and flexible membranes to apply fluid and solid mechanical stresses to single cell alveolar models to simulate the effects of mechanical ventilation and physiologic or pathologic liquid plug flows [80-82].”
BackgroundOrgan-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Self-citationMicro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Yuan, B., Jin, Y., Sun, Y., Wang, D., Sun, J., Wang, Z., Zhang, W., & Jiang, X. (2012) · Advanced Materials · doi:10.1002/adma.201104589 · Cited by 253
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Review on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“…of hydrodynamic stretching on single cells [207] [316], cell movement through fluid and/or solid environments of different geometries [317] [318] [319] [320] [321], the effect of multiple different applied forces on adherent cells [322] [323], and the chemotactic movement of cells [324] [325].”
BackgroundOrgans-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
“Few studies have investigated the possibility of applying fluid flow and mechanical stimulations in cell culture experiments, using a single cell line to emulate a more appropriate air-liquid interface microenvironment where different gas concentrations and mechanical stretching are created similar to the effects obse…”
BackgroundMicrofluidics for Drug Development: From Synthesis to Evaluation
Liu, Y., Sun, L., Zhang, H., Shang, L., & Zhao, Y. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01289 · Cited by 202
Medium throughput breathing human primary cell alveolus-on-chip model
Stucki, J. D., Hobi, N., Galimov, A., Stucki, A. O., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Frick, M., Funke-Chambour, M., Geiser, T., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32523-x · Cited by 190
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Organs-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
Self-citationHigh-Throughput Methods in the Discovery and Study of Biomaterials and Materiobiology
Yang, L., Pijuan-Galito, S., Rho, H. S., Vasilevich, A. S., Eren, A. D., Ge, L., Habibović, P., Alexander, M. R., de Boer, J., Carlier, A., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00752 · Cited by 180
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Chen, Y.-A., King, A. D., Shih, H.-C., Peng, C.-C., Wu, C.-Y., Liao, W.-H., & Tung, Y.-C. (2011) · Lab on a Chip · doi:10.1039/c1lc20325h · Cited by 185
Self-citationDynamically tunable cell culture platforms for tissue engineering and mechanobiology
Uto, K., Tsui, J. H., DeForest, C. A., & Kim, D.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.09.004 · Cited by 183
“It is related to a variety of surface tension-related diseases including acute respiratory distress syndrome (ARDS) and neonatal respiratory distress syndrome (NRDS) [200].”
BackgroundA microfluidic flow-stretch chip for investigating blood vessel biomechanics
Zheng, W., Jiang, B., Wang, D., Zhang, W., Wang, Z., & Jiang, X. (2012) · Lab on a Chip · doi:10.1039/c2lc40173h · Cited by 165
Recurrent Urinary Tract Infection: A Mystery in Search of Better Model Systems
Murray, B. O., Flores, C., Williams, C., Flusberg, D. A., Marr, E. E., Kwiatkowska, K. M., Charest, J. L., Isenberg, B. C., & Rohn, J. L. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.691210 · Cited by 183
Physiologically relevant organs on chips
Yum, K., Hong, S. G., Healy, K. E., & Lee, L. P. (2014) · Biotechnology Journal · doi:10.1002/biot.201300187 · Cited by 150
“3C) [26, 41, 44, 49] by constructing multi-layer microfluidic devices.”
BackgroundInfluentialPerspective: The promise of multi-cellular engineered living systems
Kamm, R. D., Bashir, R., Arora, N., Dar, R. D., Gillette, M. U., Griffith, L. G., Kemp, M. L., Kinlaw, K., Levin, M., Martin, A. C., et al. (2018) · APL Bioengineering · doi:10.1063/1.5038337 · Cited by 154
Self-citationChang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
Self-citationOn being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Self-citationJackson, E. L., & Lu, H. (2016) · Integrative Biology · doi:10.1039/c6ib00039h · Cited by 126
Accelerating drug discovery via organs-on-chips
Chan, C. Y., Huang, P.-H., Guo, F., Ding, X., Kapur, V., Mai, J. D., Yuen, P. K., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c3lc90115g · Cited by 125
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Air Quality Effects on Human Health and Approaches for Its Assessment through Microfluidic Chips
Schulze, F., Gao, X., Viržonis, D., Damiati, S., Schneider, M. R., & Kodzius, R. (2017) · Genes · doi:10.3390/genes8100244 · Cited by 136
“Douville and colleagues presented a similar approach, with the addition that the artificial alveoli were partially flooded with media, to additionally simulate the surface tension stress experienced by cells through the cyclic propagation of the air–liquid interface [157].”
BackgroundRespiratory microflows in the pulmonary acinus
Sznitman, J. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.10.028 · Cited by 132
“These initial efforts have demonstrated how acinar flow studies can now be conducted within physiologically realistic and functional ALI environments.”
BackgroundInfluentialBiomechanical Strain Exacerbates Inflammation on a Progeria‐on‐a‐Chip Model
Ribas, J., Zhang, Y. S., Pitrez, P. R., Leijten, J., Miscuglio, M., Rouwkema, J., Dokmeci, M. R., Nissan, X., Ferreira, L., & Khademhosseini, A. (2017) · Small · doi:10.1002/smll.201603737 · Cited by 111
Recent advances in lung-on-a-chip models
Francis, I., Shrestha, J., Paudel, K. R., Hansbro, P. M., Warkiani, M. E., & Saha, S. C. (2022) · Drug Discovery Today · doi:10.1016/j.drudis.2022.06.004 · Cited by 124
Tavana, H., Zamankhan, P., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9543-5 · Cited by 117
Self-citationGnecco, J. S., Pensabene, V., Li, D. J., Ding, T., Hui, E. E., Bruner-Tran, K. L., & Osteen, K. G. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1797-5 · Cited by 110
Organs-on-a-chip for drug discovery
Selimović, Š., Dokmeci, M. R., & Khademhosseini, A. (2013) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2013.06.005 · Cited by 113
“[25], who investigated the effects of solid and fluid mechanical stresses on cell behavior in their microfluidic lung model.”
BackgroundPatra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
Self-citationKonar, D., Devarasetty, M., Yildiz, D. V., Atala, A., & Murphy, S. V. (2016) · Biomedical Engineering and Computational Biology · doi:10.4137/becb.s34252 · Cited by 107
Badr-Eldin, S. M., Aldawsari, H. M., Kotta, S., Deb, P. K., & Venugopala, K. N. (2022) · Pharmaceuticals · doi:10.3390/ph15080926 · Cited by 118
“Lungs-on-chip was developed using microfluidic technology to study the toxicity of drugs, blockage of airways [100], oxygen transfer efficiency [101], inflammatory effects on lung cells when exposed to various pathogens or nanoparticles [102], and other stress factors [103].”
BackgroundWei, Y. Q., Mo, X., Zhang, P., Li, Y., Liao, J., Li, Y., Zhang, J., Ning, C., Wang, S., Deng, X., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b01661 · Cited by 108
Airway-On-A-Chip: Designs and Applications for Lung Repair and Disease
Bennet, T. J., Randhawa, A., Hua, J., & Cheung, K. C. (2021) · Cells · doi:10.3390/cells10071602 · Cited by 108
“Additionally, another commonly used synthetic material is polydimethylsiloxane (PDMS), which is advantageous for creating flexible membranes [40,50].”
BackgroundMethodInfluentialIncorporating mechanical strain in organs-on-a-chip: Lung and skin
Guenat, O. T., & Berthiaume, F. (2018) · Biomicrofluidics · doi:10.1063/1.5024895 · Cited by 108
Role of miR-146a in human chondrocyte apoptosis in response to mechanical pressure injury in vitro
Jin, L., Zhao, J., Jing, W., Yan, S., WANG, X., Xiao, C. Y., & Ma, B. (2014) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2014.1808 · Cited by 101
“In response to overloading external stimuli, cells are forced to die in different ways (46,47).”
RetractedWorkshop meeting report Organs-on-Chips: human disease models
van de Stolpe, A., & den Toonder, J. (2013) · Lab on a Chip · doi:10.1039/c3lc50248a · Cited by 96
An early-stage atherosclerosis research model based on microfluidics
Zheng, W., Huang, R., Jiang, B., Zhao, Y., Zhang, W., & Jiang, X. (2016) · Small · doi:10.1002/smll.201503241 · Cited by 97
Liu, M.-C., Shih, H.-C., Wu, J., Weng, T.-W., Wu, C., Lu, J.-C., & Tung, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc41414k · Cited by 96
Self-citationPrecise Control of Cell Adhesion by Combination of Surface Chemistry and Soft Lithography
Zheng, W., Zhang, W., & Jiang, X. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200104 · Cited by 100
Stem cell-based Lung-on-Chips: The best of both worlds?
Nawroth, J. C., Barrile, R., Conegliano, D., van Riet, S., Hiemstra, P. S., & Villenave, R. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.005 · Cited by 94
“Such designs support the growth of human alveolar cell lines [67,81,121] or primary [80,82,122,124] epithelial cells at an air-liquid interface, while human pulmonary microvascular endothelial cells (HMVECs) or umbilical”
Background(Micro)managing the mechanical microenvironment
Moraes, C., Sun, Y., & Simmons, C. A. (2011) · Integrative Biology · doi:10.1039/c1ib00056j · Cited by 94
A microfluidic cell culture array with various oxygen tensions
Peng, C.-C., Liao, W.-H., Chen, Y.-H., Wu, C.-Y., & Tung, Y.-C. (2013) · Lab on a Chip · doi:10.1039/c3lc50388g · Cited by 78
Self-citationA new mechanobiological era: microfluidic pathways to apply and sense forces at the cellular level
Kurth, F., Eyer, K., Franco‐Obregón, A., & Dittrich, P. S. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.03.014 · Cited by 75
“[31 ] with permission).”
BackgroundOrgan-on-a-Chip Applications in Microfluidic Platforms
An, L., Liu, Y., & Liu, Y. (2025) · Micromachines · doi:10.3390/mi16020201 · Cited by 79
“This review provides an overview of several OoC systems that have been designed, focusing on research in drug screening and disease modeling, and explores related topics such as pharmacology and cancer research [61,62].”
Yasotharan, S., Pinto, S., Sled, J. G., Bolz, S.-S., & Günther, A. (2015) · Lab on a Chip · doi:10.1039/c5lc00021a · Cited by 62
Doryab, A., Taş, S., Taskin, M. B., Yang, L., Hilgendorff, A., Gröll, J., Wagner, D. E., & Schmid, O. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201903114 · Cited by 70
Review of the role of surfactant dynamics in drop microfluidics
Kovalchuk, N. M., & Simmons, M. J. H. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.102844 · Cited by 66
“It should be noted that large shear stresses can be injurious and even deadly for some types of cells [34,35].”
Engineering Liver Microtissues for Disease Modeling and Regenerative Medicine
Huang, D. (., Gibeley, S. B., Xu, C., Xiao, Y., Celik, O., Ginsberg, H. N., & Leong, K. W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909553 · Cited by 65
Microtechnology for Mimicking In Vivo Tissue Environment
Sung, J. H., & Shuler, M. L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0491-2 · Cited by 70
Higuita‐Castro, N., Nelson, M. T., Shukla, V. C., Agudelo-Garcia, P. A., Zhang, W., Duarte‐Sanmiguel, S., Englert, J. A., Lannutti, J. J., Hansford, D. J., & Ghadiali, S. N. (2017) · Scientific Reports · doi:10.1038/s41598-017-12044-9 · Cited by 63
Biomimetic human lung-on-a-chip for modeling disease investigation
Li, K., Yang, X., Xue, C., Zhao, L., Zhang, Y., & Gao, X. (2019) · Biomicrofluidics · doi:10.1063/1.5100070 · Cited by 65
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Maturavongsadit, P., Paravyan, G., Shrivastava, R., & Benhabbour, S. R. (2020) · Materialia · doi:10.1016/j.mtla.2020.100681 · Cited by 64
3D alveolar in vitro model based on epithelialized biomimetically curved culture membranes
Baptista, D., Teixeira, L. M., Birgani, Z. N. T., van Riet, S., Pasman, T., Poot, A. A., Stamatialis, D. F., Rottier, R. J., Hiemstra, P. S., Habibović, P., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120436 · Cited by 61
“conjunction with solid mechanical und surface tension fluid mechanical stress [58].”
BackgroundBiosynthetic, biomimetic, and self-assembled vascularized Organ-on-a-Chip systems
Fritschen, A., & Blaeser, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120556 · Cited by 65
Organs on microfluidic chips: A mini review
Jiang, B., Zheng, W., Zhang, W., & Jiang, X. (2013) · Science China Chemistry · doi:10.1007/s11426-013-4971-0 · Cited by 62
Revisiting Airflow and Aerosol Transport Phenomena in the Deep Lungs with Microfluidics
Sznitman, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00621 · Cited by 66
Microfluidic-Based Multi-Organ Platforms for Drug Discovery
Rezaei Kolahchi, A., Khadem Mohtaram, N., Pezeshgi Modarres, H., Mohammadi, M., Geraili, A., Jafari, P., Akbari, M., & Sanati-Nezhad, A. (2016) · Micromachines · doi:10.3390/mi7090162 · Cited by 53
“Researchers combined the mechanical [172,173], biomaterial [174,175], and topographical [176] characteristics on in vitro models to recreate in vivo functionality as a novel approach towards drug testing.”
BackgroundPulmonary Fluid Flow Challenges for Experimental and Mathematical Modeling
Levy, R., Hill, D. B., Forest, M. G., & Grotberg, J. B. (2014) · Integrative and Comparative Biology · doi:10.1093/icb/icu107 · Cited by 55
“…during both the closure and the reopening of flow and can lead to injury and/or death of epithelial cells (Taskar et al. 1997; D’Angelo et al. 2002; Bilek et al. 2003; Dailey et al. 2007; Huh et al. 2007; Yalcin et al. 2007, 2009; Ghadiali and Gaver 2008; Douville et al. 2011; Tavana et al. 2011).”
BackgroundSelf-citationIn situ-Like Aerosol Inhalation Exposure for Cytotoxicity Assessment Using Airway-on-Chips Platforms
Elias‐Kirma, S., Artzy‐Schnirman, A., Das, P., Heller-Algazi, M., Korin, N., & Sznitman, J. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00091 · Cited by 57
“Together with other recent efforts (Douville et al., 2011; Nesmith et al., 2014; Stucki et al., 2014; Li et al., 2015; Hassell et al., 2017; Humayun et al., 2018), these studies have brought tremendous progress in lung research but are still widely limited to platforms with a single airway channel,…”
BackgroundHydrogel-based methods for engineering cellular microenvironment with spatiotemporal gradients
Wang, L., Li, Y., Huang, G., Zhang, X., Pingguan‐Murphy, B., Gao, B., Lu, T. J., & Xu, F. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.993588 · Cited by 57
“…in tissues result from various physiological processes in vivo, such as inflammation, drainage toward lymphatics, muscle contraction, which drive fluid flow stress through ECM and locally elevated stresses caused by leaky microvessels and tumor growth (Douville et al., 2011; Jang et al., 2011).”
BackgroundMicrofluidic approaches for epithelial cell layer culture and characterisation
Thuenauer, R., Rodriguez-Boulan, E. J., & Römer, W. (2014) · The Analyst · doi:10.1039/c4an00056k · Cited by 59
Biomimetics of the pulmonary environment in vitro: A microfluidics perspective
Tenenbaum‐Katan, J., Artzy‐Schnirman, A., Fishler, R., Korin, N., & Sznitman, J. (2018) · Biomicrofluidics · doi:10.1063/1.5023034 · Cited by 52
Abo, K. M., Sainz de Aja, J., Lindstrom-Vautrin, J., Alysandratos, K.-D., Richards, A., Garcia-de-Alba, C., Huang, J., Hix, O. T., Werder, R. B., Bullitt, E., et al. (2022) · JCI Insight · doi:10.1172/jci.insight.155589 · Cited by 48
“have been used in alveolar epithelial ALI cultures (30, 31).”
MethodTwo-Aperture Microfluidic Probes as Flow Dipoles: Theory and Applications
Safavieh, M., Qasaimeh, M. A., Vakil, A., Juncker, D., & Gervais, T. (2015) · Scientific Reports · doi:10.1038/srep11943 · Cited by 47
Micro and Nano-Scale Technologies for Cell Mechanics
Ünal, M., Alapan, Y., Jia, H. W., Varga, A. G., Angelino, K., Aslan, M., Sayın, I., Han, C., Jiang, Y., Zhang, Z., et al. (2014) · Nanobiomedicine · doi:10.5772/59379 · Cited by 54
“There have been encouraging breakthroughs in devising and constructing devices that resemble the structure of the human lungs [172-174], liver [175-178], intestines [164,179,180], kidneys [181,182], cancer tissue [183] and artificial cells in regenerative medicine [117,166,170].”
BackgroundMimicking and analyzing the tumor microenvironment
Crouigneau, R., Li, Y., Auxillos, J., Gonçalves‐Alves, E., Marie, R., Sandelin, A., & Pedersen, S. F. (2024) · Cell Reports Methods · doi:10.1016/j.crmeth.2024.100866 · Cited by 53
Miller, P. G., Chen, C., Wang, Y. I., Gao, E., & Shuler, M. L. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27188 · Cited by 44
The potential of microfluidic lung epithelial wounding: towardsin vivo-like alveolar microinjuries
Felder, M., Stucki, A., Stucki, J. D., Geiser, T., & Guenat, O. T. (2014) · Integrative Biology · doi:10.1039/c4ib00149d · Cited by 41
Liquid plug formation in an airway closure model
Romanò, F., Fujioka, H., Muradoğlu, M., & Grotberg, J. B. (2019) · Physical Review Fluids · doi:10.1103/physrevfluids.4.093103 · Cited by 39
Self-citationRecapitulating essential pathophysiological characteristics in lung-on-a-chip for disease studies
Zhang, Y., Wang, X., Yang, Y. L., Yan, J., Xiong, Y., Wang, W., Lei, J., & Jiang, T. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1093460 · Cited by 40
“Dynamic respiratory motion is also a key component in lung-ona-chip construction (60).”
BackgroundMahto, S. K., Tenenbaum‐Katan, J., Greenblum, A., Rothen‐Rutishauser, B., & Sznitman, J. (2014) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00106.2013 · Cited by 37
“In recent years, microfluidic devices have been increasingly utilized to recreate in vitro models of cellular lung airway and alveolar environments and investigate among other cell injury under mechanical stretching conditions (16, 25, 26, 31).”
BackgroundInfluentialCarugo, D., Owen, J., Crake, C., Lee, J. Y., & Stride, E. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.020 · Cited by 36
“The shear stress in this region ranges from 6 3 10(25) to 2 3 10(24) Pa, which is significantly lower than values reported to induce cell detachment (Douville et al. 2011), reduce cell viability or elicit a biological response (Hua et al.”
BackgroundRole of Airway Recruitment and Derecruitment in Lung Injury
Ghadiali, S. N., & Huang, Y. (2011) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i4.40 · Cited by 42
Capturing the Onset of Bacterial Pulmonary Infection in Acini‐On‐Chips
Artzy‐Schnirman, A., Zidan, H., Elias‐Kirma, S., Ben‐Porat, L., Tenenbaum‐Katan, J., Carius, P., Fishler, R., Schneider‐Daum, N., Lehr, C., & Sznitman, J. (2019) · Advanced Biosystems · doi:10.1002/adbi.201900026 · Cited by 37
Deformation of double emulsions under conditions of flow cytometry hydrodynamic focusing
Ma, S., Huck, W. T. S., & Balabani, S. (2015) · Lab on a Chip · doi:10.1039/c5lc00693g · Cited by 35
Effect of Microculture on Cell Metabolism and Biochemistry: Do Cells Get Stressed in Microchannels?
Su, X., Theberge, A. B., January, C. T., & Beebe, D. J. (2013) · Analytical Chemistry · doi:10.1021/ac3027228 · Cited by 35
Organs-on-chips and Its Applications
Sun, W., Chen, Y., Luo, G., Zhang, M., Zhang, H., Wang, Y., & Hu, P. (2016) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(16)60920-9 · Cited by 42
Organ-on-a-Chip Platforms for Drug Screening and Tissue Engineering
Wang, Z., Samanipour, R., & Kim, K. (2015) · Biosystems & biorobotics · doi:10.1007/978-3-319-21813-7_10 · Cited by 41
Stretchable impedance sensor for mammalian cell proliferation measurements
Zhang, X., Wang, W., Li, F., & Voiculescu, I. (2017) · Lab on a Chip · doi:10.1039/c7lc00375g · Cited by 36
Bajaj, P., Harris, J. F., Huang, J., Nath, P., & Iyer, R. S. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00480 · Cited by 37
Alveolar mimics with periodic strain and its effect on the cell layer formation
Radiom, M., He, Y., Peng, J., Baeza‐Squiban, A., Berret, J., & Chen, Y. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27458 · Cited by 34
Influence of airway wall compliance on epithelial cell injury and adhesion during interfacial flows
Higuita‐Castro, N., Mihai, C., Hansford, D. J., & Ghadiali, S. N. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00752.2013 · Cited by 36
Challenge in particle delivery to cells in a microfluidic device
Moghadas, H., Saidi, M. S., Kashaninejad, N., & Nguyen, N. (2017) · Drug Delivery and Translational Research · doi:10.1007/s13346-017-0467-3 · Cited by 34
Metadata
- Authors
- Douville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Grotberg, James B.
- Takayama, Shuichi
- ORCID
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 4
- Pages
- 609-619
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2155681477
- Semantic Scholar
- b0900d1615e814b7d5d9eb49f6fd6cdc5319db66
- Cited by
- 216
- References
- 35
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 15 · 2023: 7 · 2022: 12 · 2021: 16 · 2020: 13 · 2019: 17 · 2018: 20 · 2017: 15 · 2016: 17 · 2015: 15 · 2014: 15 · 2013: 20 · 2012: 14
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL-084370, R01HL085156, F30HL095333, R01HL084370, HL 85156)
- National Institute of General Medical Sciences (T 32 GM07863, T32GM007863)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- alveolar epithelial cells, surface tension, cyclic strain, air-liquid interface, cell death, cell detachment, surfactant dysfunction, A549 cells
- MeSH terms
- Animals, Biomechanical Phenomena, Cell Adhesion, Cell Line, Transformed, Humans, Models, Biological, Pulmonary Alveoli, Stress, Mechanical, Surface Tension, Cell Death, Respiratory Mucosa, Microfluidic Analytical Techniques, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.