The DOI matches its Crossref record.
Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay
Abstract
Antibody immobilization strategies (random, covalent, orientated and combinations of each) were examined to determine their performance in a surface plasmon resonance-based immunoassay using human fetuin A (HFA) as the model antigen system. The random antibody immobilization strategy selected was based on passive adsorption of anti-HFA antibody on 3-aminopropyltriethoxysilane (APTES)-functionalized gold (Au) chips. The covalent strategy employed covalent crosslinking of anti-HFA antibody on APTES-functionalized chips using 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide (EDC) and sulfo-N-hydroxysuccinimide (SNHS). The orientation strategy used passive adsorption of protein A (PrA) on Au chips, with subsequent binding of the anti-HFA antibody in an orientated fashion via its fragment crystallisable (Fc) region. In the covalent-orientated strategy, PrA was first bound covalently, to the surface, which in turn, then binds the anti-HFA antibody in an orientated manner. Finally, in the most widely used strategy, covalent binding of anti-HFA antibody to carboxymethyldextran (CM5-dextran) was employed. This immobilization strategy gave the highest anti-HFA antibody immobilization density, whereas the highest HFA response was obtained with the covalent-orientated immobilization strategy. Therefore, the covalent-orientated strategy was the best for SPR-based HFA immunoassay and can detect 0.6-20.0 ng/mL of HFA in less than 10 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Antibody orientation on biosensor surfaces: a minireview
Trilling, A. K., Beekwilder, J., & Zuilhof, H. (2013) · The Analyst · doi:10.1039/c2an36787d · Cited by 466
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017) · Biointerphases · doi:10.1116/1.4978435 · Cited by 414
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Wu, Q., Li, N., Wang, Y., liu, Y., Xu, Y., Wei, S., Wu, J., Jia, G., Fang, X., Chen, F., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111697 · Cited by 256
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Metadata
- Authors
- Vashist, S. K., Dixit, C. K., MacCraith, B. D., & O'Kennedy, R.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 136
- Issue
- 21
- Pages
- 4431
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2150364024
- Cited by
- 179
- References
- 0
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay. https://app.cochat.ai/papers/10.1039/c1an15325k
- The paper
- Vashist, S. K., Dixit, C. K., MacCraith, B. D., & O'Kennedy, R. (2011). Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay. The Analyst. https://doi.org/10.1039/c1an15325k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.